Comparison of Intraocular Pressure Measurements Obtained by Icare PRO Rebound Tonometer, Tomey FT-1000 Noncontact Tonometer, and Goldmann Applanation Tonometer in Healthy Subjects. Issue 8 (October 2015)
- Record Type:
- Journal Article
- Title:
- Comparison of Intraocular Pressure Measurements Obtained by Icare PRO Rebound Tonometer, Tomey FT-1000 Noncontact Tonometer, and Goldmann Applanation Tonometer in Healthy Subjects. Issue 8 (October 2015)
- Main Title:
- Comparison of Intraocular Pressure Measurements Obtained by Icare PRO Rebound Tonometer, Tomey FT-1000 Noncontact Tonometer, and Goldmann Applanation Tonometer in Healthy Subjects
- Authors:
- Güler, Mete
Bilak, Şemsettin
Bilgin, Burak
Şimşek, Ali
Çapkin, Musa
Hakim Reyhan, Ali - Abstract:
- Abstract : Purpose: To compare intraocular pressure (IOP) measurements obtained by Icare PRO rebound tonometer (RT), Tomey FT-1000 noncontact tonometer (NCT), and Goldmann applanation tonometer (GAT) in healthy subjects, and to investigate the influence of central corneal thickness (CCT) on IOP measurements. Methods: A total of 132 eyes of 66 healthy subjects were included in the study. All IOP measurements were applied in a sitting position and always in the same order (RT, NCT, and GAT). CCT was measured by noncontact anterior segment optical coherence tomography. Results: The mean CCT was 523.5±31.2 μm. The mean IOPs with GAT, NCT, and RT measurements were 14.56±2.77, 13.42±2.99, 14.18±2.55 mm Hg, respectively. A significantly good agreement was found between RT and GAT measurements ( P =0.515). The mean difference between RT and GAT measurements was −0.38 mm Hg. An underestimation was found in NCT measurements compared with GAT ones as defined from paired comparisons ( P =0.003). The mean difference between NCT and GAT measurements was −1.14 mm Hg. There was no significant difference between NCT and RT readings ( P =0.069). The mean difference between NCT and RT measurements was −0.76 mm Hg. There was a significant correlation between GAT-NCT ( r =0.740, P <0.001), GAT-RT ( r =0.743, P <0.001), NCT-RT ( r =0.729, P <0.001) measurement methods. The increment in measured IOP for a 10 μm increase in CCT was 0.16, 0.33, and 0.18 mm Hg for the GAT, NCT, and RT, respectively.Abstract : Purpose: To compare intraocular pressure (IOP) measurements obtained by Icare PRO rebound tonometer (RT), Tomey FT-1000 noncontact tonometer (NCT), and Goldmann applanation tonometer (GAT) in healthy subjects, and to investigate the influence of central corneal thickness (CCT) on IOP measurements. Methods: A total of 132 eyes of 66 healthy subjects were included in the study. All IOP measurements were applied in a sitting position and always in the same order (RT, NCT, and GAT). CCT was measured by noncontact anterior segment optical coherence tomography. Results: The mean CCT was 523.5±31.2 μm. The mean IOPs with GAT, NCT, and RT measurements were 14.56±2.77, 13.42±2.99, 14.18±2.55 mm Hg, respectively. A significantly good agreement was found between RT and GAT measurements ( P =0.515). The mean difference between RT and GAT measurements was −0.38 mm Hg. An underestimation was found in NCT measurements compared with GAT ones as defined from paired comparisons ( P =0.003). The mean difference between NCT and GAT measurements was −1.14 mm Hg. There was no significant difference between NCT and RT readings ( P =0.069). The mean difference between NCT and RT measurements was −0.76 mm Hg. There was a significant correlation between GAT-NCT ( r =0.740, P <0.001), GAT-RT ( r =0.743, P <0.001), NCT-RT ( r =0.729, P <0.001) measurement methods. The increment in measured IOP for a 10 μm increase in CCT was 0.16, 0.33, and 0.18 mm Hg for the GAT, NCT, and RT, respectively. Conclusions: The IOP readings with the new Icare PRO RT showed good correlation with those obtained by GAT. Tomey FT-1000 NCT underestimated the IOP compared with GAT. … (more)
- Is Part Of:
- Journal of glaucoma. Volume 24:Issue 8(2015:Oct./Nov.)
- Journal:
- Journal of glaucoma
- Issue:
- Volume 24:Issue 8(2015:Oct./Nov.)
- Issue Display:
- Volume 24, Issue 8 (2015)
- Year:
- 2015
- Volume:
- 24
- Issue:
- 8
- Issue Sort Value:
- 2015-0024-0008-0000
- Page Start:
- Page End:
- Publication Date:
- 2015-10
- Subjects:
- central corneal thickness -- Goldmann applanation tonometer -- intraocular pressure -- noncontact tonometer -- rebound tonometer
Glaucoma -- Periodicals
617.741005 - Journal URLs:
- http://ovidsp.ovid.com/ovidweb.cgi?T=JS&NEWS=n&CSC=Y&PAGE=toc&D=yrovft&AN=00061198-000000000-00000 ↗
http://www.glaucomajournal.com ↗
http://journals.lww.com/glaucomajournal/pages/default.aspx ↗
http://journals.lww.com ↗ - DOI:
- 10.1097/IJG.0000000000000132 ↗
- Languages:
- English
- ISSNs:
- 1057-0829
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4996.230000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 5260.xml