Effects of myocardial perfusion abnormalities on the accuracy of left ventricular volume and ejection fraction measured by thallium-201 gated single-photon emission tomography: comparison with echocardiography as the reference standard. Issue 11 (November 2015)
- Record Type:
- Journal Article
- Title:
- Effects of myocardial perfusion abnormalities on the accuracy of left ventricular volume and ejection fraction measured by thallium-201 gated single-photon emission tomography: comparison with echocardiography as the reference standard. Issue 11 (November 2015)
- Main Title:
- Effects of myocardial perfusion abnormalities on the accuracy of left ventricular volume and ejection fraction measured by thallium-201 gated single-photon emission tomography
- Authors:
- Kurisu, Satoshi
Iwasaki, Toshitaka
Abe, Nobukazu
Tamura, Megumi
Ikenaga, Hiroki
Watanabe, Noriaki
Higaki, Tadanao
Shimonaga, Takashi
Ishibashi, Ken
Dohi, Yoshihiro
Fukuda, Yukihiro
Kihara, Yasuki - Abstract:
- Abstract : Background: We assessed the accuracy of left ventricular end-diastolic volume (EDV), end-systolic volume (ESV), and ejection fraction (EF) using quantitative gated single-photon emission computed tomography (QGS) in comparison with echocardiography as the reference standard. We also assessed the effects of total perfusion deficit (TPD) on the accuracy of QGS measurements. Methods: A total of 258 patients underwent single-photon emission computed tomography and transthoracic echocardiography within 4 weeks of each investigation for evaluating coronary artery disease. Patients were divided into four groups according to TPD scores. Results: There were 138 patients with no/minimal TPD, 64 patients with small TPD, 35 patients with middle TPD, and 21 patients with large TPD. There were good correlations and agreements in EDV ( r =0.87, 0.90, 0.71, and 0.94, respectively), ESV ( r =0.92, 0.94, 0.79, and 0.94, respectively), and EF ( r =0.61, 0.79, 0.61, and 0.83, respectively) between QGS and echocardiography in patients with any TPD. QGS significantly underestimated EDV and ESV in patients with no/minimal or small TPD, and significantly overestimated ESV in patients with large TPD. QGS significantly underestimated EF in patients with middle or large TPD. Conclusion: Our results suggest that QGS is a useful tool for assessing the left ventricular volume and function in patients with any TPD, but myocardial perfusion abnormalities should be taken into consideration whenAbstract : Background: We assessed the accuracy of left ventricular end-diastolic volume (EDV), end-systolic volume (ESV), and ejection fraction (EF) using quantitative gated single-photon emission computed tomography (QGS) in comparison with echocardiography as the reference standard. We also assessed the effects of total perfusion deficit (TPD) on the accuracy of QGS measurements. Methods: A total of 258 patients underwent single-photon emission computed tomography and transthoracic echocardiography within 4 weeks of each investigation for evaluating coronary artery disease. Patients were divided into four groups according to TPD scores. Results: There were 138 patients with no/minimal TPD, 64 patients with small TPD, 35 patients with middle TPD, and 21 patients with large TPD. There were good correlations and agreements in EDV ( r =0.87, 0.90, 0.71, and 0.94, respectively), ESV ( r =0.92, 0.94, 0.79, and 0.94, respectively), and EF ( r =0.61, 0.79, 0.61, and 0.83, respectively) between QGS and echocardiography in patients with any TPD. QGS significantly underestimated EDV and ESV in patients with no/minimal or small TPD, and significantly overestimated ESV in patients with large TPD. QGS significantly underestimated EF in patients with middle or large TPD. Conclusion: Our results suggest that QGS is a useful tool for assessing the left ventricular volume and function in patients with any TPD, but myocardial perfusion abnormalities should be taken into consideration when interpreting QRS measurements. … (more)
- Is Part Of:
- Nuclear medicine communications. Volume 36:Issue 11(2015:Nov.)
- Journal:
- Nuclear medicine communications
- Issue:
- Volume 36:Issue 11(2015:Nov.)
- Issue Display:
- Volume 36, Issue 11 (2015)
- Year:
- 2015
- Volume:
- 36
- Issue:
- 11
- Issue Sort Value:
- 2015-0036-0011-0000
- Page Start:
- Page End:
- Publication Date:
- 2015-11
- Subjects:
- agreement -- left ventricular function -- left ventricular volume -- myocardial infarction
Nuclear medicine -- Periodicals
616.07575 - Journal URLs:
- http://journals.lww.com/nuclearmedicinecomm/pages/default.aspx ↗
http://journals.lww.com/pages/default.aspx ↗
http://www.lww.com/Product/0143-3636 ↗ - DOI:
- 10.1097/MNM.0000000000000369 ↗
- Languages:
- English
- ISSNs:
- 0143-3636
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 6180.923000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 5229.xml