Accuracy of home versus ambulatory blood pressure monitoring in the diagnosis of white-coat and masked hypertension. Issue 8 (August 2015)
- Record Type:
- Journal Article
- Title:
- Accuracy of home versus ambulatory blood pressure monitoring in the diagnosis of white-coat and masked hypertension. Issue 8 (August 2015)
- Main Title:
- Accuracy of home versus ambulatory blood pressure monitoring in the diagnosis of white-coat and masked hypertension
- Authors:
- Kang, Yuan-Yuan
Li, Yan
Huang, Qi-Fang
Song, Jie
Shan, Xiao-Li
Dou, Yu
Xu, Xin-Juan
Chen, Shou-Hong
Wang, Ji-Guang - Abstract:
- Abstract : Background: We investigated accuracy of home blood pressure (BP) monitoring in the diagnosis of white-coat and masked hypertension in comparison with ambulatory BP monitoring. Methods: Our study participants were enrolled in the China Ambulatory and Home BP Registry, and underwent clinic, home, and 24-h ambulatory BP measurements. We defined white-coat hypertension as an elevated clinic SBP/DBP (≥140/90 mmHg) and a normal 24-h ambulatory (<130/80 mmHg) or home SBP/DBP (<135/85 mmHg), and masked hypertension as a normal clinic SBP/DBP (<140/90 mmHg) and an elevated 24-h ambulatory (≥130/80 mmHg) or home SBP/DBP (≥135/85 mmHg). Results: In untreated patients ( n = 573), the prevalence of white-coat hypertension (13.1 vs. 19.9%), masked hypertension (17.8 vs. 13.1%), and sustained hypertension (46.4 vs. 39.6%) significantly ( P ⩽ 0.02) differed between 24-h ambulatory and home BP monitoring. In treated patients ( n = 1201), only the prevalence of masked hypertension differed significantly (18.7 vs. 14.5%; P = 0.005). Regardless of the treatment status, home compared with 24-h ambulatory BP had low sensitivity (range 47–74%), but high specificity (86–94%), and accordingly low positive (41–87%), but high negative predictive values (80–94%), and had moderate diagnostic agreement (82–85%) and Kappa statistic (0.41–0.66). In untreated and treated patients, age advancing was associated with a higher prevalence of white-coat hypertension and a lower prevalence of maskedAbstract : Background: We investigated accuracy of home blood pressure (BP) monitoring in the diagnosis of white-coat and masked hypertension in comparison with ambulatory BP monitoring. Methods: Our study participants were enrolled in the China Ambulatory and Home BP Registry, and underwent clinic, home, and 24-h ambulatory BP measurements. We defined white-coat hypertension as an elevated clinic SBP/DBP (≥140/90 mmHg) and a normal 24-h ambulatory (<130/80 mmHg) or home SBP/DBP (<135/85 mmHg), and masked hypertension as a normal clinic SBP/DBP (<140/90 mmHg) and an elevated 24-h ambulatory (≥130/80 mmHg) or home SBP/DBP (≥135/85 mmHg). Results: In untreated patients ( n = 573), the prevalence of white-coat hypertension (13.1 vs. 19.9%), masked hypertension (17.8 vs. 13.1%), and sustained hypertension (46.4 vs. 39.6%) significantly ( P ⩽ 0.02) differed between 24-h ambulatory and home BP monitoring. In treated patients ( n = 1201), only the prevalence of masked hypertension differed significantly (18.7 vs. 14.5%; P = 0.005). Regardless of the treatment status, home compared with 24-h ambulatory BP had low sensitivity (range 47–74%), but high specificity (86–94%), and accordingly low positive (41–87%), but high negative predictive values (80–94%), and had moderate diagnostic agreement (82–85%) and Kappa statistic (0.41–0.66). In untreated and treated patients, age advancing was associated with a higher prevalence of white-coat hypertension and a lower prevalence of masked hypertension defined by 24-h ambulatory ( P ⩽ 0.03) but not home BP ( P ≥ 0.10). Conclusion: Home BP monitoring has high specificity, but low sensitivity in the diagnosis of white-coat and masked hypertension, and may therefore behave as a complementary to, but not a replacement of, ambulatory BP monitoring. Abstract : Supplemental Digital Content is available in the text … (more)
- Is Part Of:
- Journal of hypertension. Volume 33:Issue 8(2015:Aug.)
- Journal:
- Journal of hypertension
- Issue:
- Volume 33:Issue 8(2015:Aug.)
- Issue Display:
- Volume 33, Issue 8 (2015)
- Year:
- 2015
- Volume:
- 33
- Issue:
- 8
- Issue Sort Value:
- 2015-0033-0008-0000
- Page Start:
- Page End:
- Publication Date:
- 2015-08
- Subjects:
- ambulatory blood pressure -- diagnosis -- home blood pressure -- masked hypertension -- white coat hypertension
Hypertension -- Periodicals
Hypertension -- Periodicals
616.132005 - Journal URLs:
- http://firstsearch.oclc.org ↗
http://journals.lww.com/jhypertension/pages/default.aspx ↗
http://ovidsp.ovid.com/ovidweb.cgi?T=JS&NEWS=n&CSC=Y&PAGE=toc&D=yrovft&AN=00004872-000000000-00000 ↗
http://www.jhypertension.com/ ↗
http://journals.lww.com/pages/default.aspx ↗ - DOI:
- 10.1097/HJH.0000000000000596 ↗
- Languages:
- English
- ISSNs:
- 1473-5598
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5004.510000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 5247.xml