Quantitative, Organ-Specific Interscanner and Intrascanner Variability for 3 T Whole-Body Magnetic Resonance Imaging in a Multicenter, Multivendor Study. Issue 4 (April 2016)
- Record Type:
- Journal Article
- Title:
- Quantitative, Organ-Specific Interscanner and Intrascanner Variability for 3 T Whole-Body Magnetic Resonance Imaging in a Multicenter, Multivendor Study. Issue 4 (April 2016)
- Main Title:
- Quantitative, Organ-Specific Interscanner and Intrascanner Variability for 3 T Whole-Body Magnetic Resonance Imaging in a Multicenter, Multivendor Study
- Authors:
- Schlett, Christopher L.
Hendel, Thomas
Hirsch, Jochen
Weckbach, Sabine
Caspers, Svenja
Schulz-Menger, Jeanette
Ittermann, Till
von Knobelsdorff-Brenkenhoff, Florian
Ladd, Susanne C.
Moebus, Susanne
Stroszczynski, Christian
Fischer, Beate
Leitzmann, Michael
Kuhl, Christiane
Pessler, Frank
Hartung, Dagmar
Kemmling, Yvonne
Hetterich, Holger
Amunts, Katrin
Günther, Matthias
Wacker, Frank
Rummeny, Ernst
Kauczor, Hans-Ulrich
Forsting, Michael
Völzke, Henry
Hosten, Norbert
Reiser, Maximilian F.
Bamberg, Fabian - Abstract:
- Abstract : Introduction: Whole-body magnetic resonance (MR) imaging is increasingly implemented in population-based cohorts and clinical settings. However, to quantify the variability introduced by the different scanners is essential to make conclusions about clinical and biological data, and relevant for internal/external validity. Thus, we determined the interscanner and intrascanner variability of different 3 T MR scanners for whole-body imaging. Methods: Thirty volunteers were enrolled to undergo multicentric, interscanner as well intrascanner imaging as part of the German National Cohort pilot studies. A comprehensive whole-body MR protocol was installed at 9 sites including 7 different MR scanner models by all 4 major vendors. A set of quantitative, organ-specific measures (n = 20; eg, volume of brain's gray/white matter, pulmonary trunk diameter, vertebral body height) were obtained in blinded fashion. Reproducibility was determined using mean weighted relative differences and intraclass correlation coefficients. Results: All participants (44 ± 14 years, 50% female) successfully completed the imaging protocol except for two because of technical issues. Mean scan time was 2 hours and 32 minutes and differed significantly across scanners (range, 1 hour 59 minutes to 3 hours 12 minutes). A higher reproducibility of obtained measurements was observed for intrascanner than for interscanner comparisons (intraclass correlation coefficients, 0.80 ± 0.17 vs 0.60 ± 0.31, P =Abstract : Introduction: Whole-body magnetic resonance (MR) imaging is increasingly implemented in population-based cohorts and clinical settings. However, to quantify the variability introduced by the different scanners is essential to make conclusions about clinical and biological data, and relevant for internal/external validity. Thus, we determined the interscanner and intrascanner variability of different 3 T MR scanners for whole-body imaging. Methods: Thirty volunteers were enrolled to undergo multicentric, interscanner as well intrascanner imaging as part of the German National Cohort pilot studies. A comprehensive whole-body MR protocol was installed at 9 sites including 7 different MR scanner models by all 4 major vendors. A set of quantitative, organ-specific measures (n = 20; eg, volume of brain's gray/white matter, pulmonary trunk diameter, vertebral body height) were obtained in blinded fashion. Reproducibility was determined using mean weighted relative differences and intraclass correlation coefficients. Results: All participants (44 ± 14 years, 50% female) successfully completed the imaging protocol except for two because of technical issues. Mean scan time was 2 hours and 32 minutes and differed significantly across scanners (range, 1 hour 59 minutes to 3 hours 12 minutes). A higher reproducibility of obtained measurements was observed for intrascanner than for interscanner comparisons (intraclass correlation coefficients, 0.80 ± 0.17 vs 0.60 ± 0.31, P = 0.005, respectively). In the interscanner comparison, mean relative difference ranged from 1.0% to 53.2%. Conversely, in the intrascanner comparison, mean relative difference ranged from 0.1% to 15.6%. There were no statistical differences for intrascanner and interscanner reproducibility between the different organ foci (all P ≥ 0.24). Conclusions: While whole-body MR imaging-derived, organ-specific parameters are generally associated with good to excellent reproducibility, smaller differences are obtained when using identical MR scanner models by a single vendor. … (more)
- Is Part Of:
- Investigative radiology. Volume 51:Issue 4(2016:Apr.)
- Journal:
- Investigative radiology
- Issue:
- Volume 51:Issue 4(2016:Apr.)
- Issue Display:
- Volume 51, Issue 4 (2016)
- Year:
- 2016
- Volume:
- 51
- Issue:
- 4
- Issue Sort Value:
- 2016-0051-0004-0000
- Page Start:
- Page End:
- Publication Date:
- 2016-04
- Subjects:
- whole-body imaging -- population-based imaging -- German National Cohort -- reproducibility -- variability -- 3 T magnetic resonance tomography
Diagnosis, Radioscopic -- Periodicals
Radiology, Medical -- Periodicals
616.0757 - Journal URLs:
- http://journals.lww.com/investigativeradiology/pages/default.aspx ↗
http://journals.lww.com ↗ - DOI:
- 10.1097/RLI.0000000000000237 ↗
- Languages:
- English
- ISSNs:
- 0020-9996
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4560.350000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 5217.xml