Dynamic Contrast-Enhanced Magnetic Resonance Imaging for Quantitative Lung Perfusion Imaging Using the Dual-Bolus Approach: Comparison of 3 Contrast Agents and Recommendation of Feasible Doses. Issue 3 (March 2016)
- Record Type:
- Journal Article
- Title:
- Dynamic Contrast-Enhanced Magnetic Resonance Imaging for Quantitative Lung Perfusion Imaging Using the Dual-Bolus Approach: Comparison of 3 Contrast Agents and Recommendation of Feasible Doses. Issue 3 (March 2016)
- Main Title:
- Dynamic Contrast-Enhanced Magnetic Resonance Imaging for Quantitative Lung Perfusion Imaging Using the Dual-Bolus Approach
- Authors:
- Veldhoen, Simon
Oechsner, Markus
Fischer, Andre
Weng, Andreas Max
Kunz, Andreas Steven
Bley, Thorsten Alexander
Köstler, Herbert
Ritter, Christian Oliver - Abstract:
- Abstract : Objective: The aims of this study were to compare 3 contrast agents and to define feasible doses for quantitative lung perfusion imaging using the dual-bolus approach in dynamic contrast-enhanced (DCE) magnetic resonance imaging (MRI). Materials and Methods: Ten healthy volunteers (6 males, 4 females; mean age, 23.5 years) underwent DCE-MRI at 1.5 T using a 3D FLASH sequence. After a prebolus, 3 doses of gadopentetate dimeglumine (Gd-DTPA), gadofosveset, and gadobenate dimeglumine (Gd-BOPTA) were evaluated. Dose regimes were as follows: Gd-DTPA: 3.0 mL, 6.0 mL, and 12.0 mL with 1.5 mL prebolus; gadofosveset: 1.5 mL, 3.0 mL, and 6.0 mL with 0.8 mL prebolus; and Gd-BOPTA: 1.5 mL, 3.0 mL, and 6.0 mL with 0.8 mL prebolus. Pulmonary blood flow (PBF), pulmonary distribution volume, and mean transit time were assessed for each bolus. Region of interest measurements were used to determine the arterial input function (AIF) in the pulmonary trunk and signal intensities in lung parenchyma. Two radiologists independently rated the subjective image quality of the quantitative perfusion maps based on a 4-point Likert scale. Results: Dose-dependent signal saturation effects were observed for all 3 contrast agents concerning AIF and parenchyma measurements. Signal yields were comparable using Gd-BOPTA (AIF, 214.49 arbitrary units [AU]; parenchyma, 41.7 AU) and Gd-DTPA (207.43 AU; 36.3 AU). Gadofosveset showed significantly lower signal yield (165.74 AU; 25.2 AU; p < 0.008).Abstract : Objective: The aims of this study were to compare 3 contrast agents and to define feasible doses for quantitative lung perfusion imaging using the dual-bolus approach in dynamic contrast-enhanced (DCE) magnetic resonance imaging (MRI). Materials and Methods: Ten healthy volunteers (6 males, 4 females; mean age, 23.5 years) underwent DCE-MRI at 1.5 T using a 3D FLASH sequence. After a prebolus, 3 doses of gadopentetate dimeglumine (Gd-DTPA), gadofosveset, and gadobenate dimeglumine (Gd-BOPTA) were evaluated. Dose regimes were as follows: Gd-DTPA: 3.0 mL, 6.0 mL, and 12.0 mL with 1.5 mL prebolus; gadofosveset: 1.5 mL, 3.0 mL, and 6.0 mL with 0.8 mL prebolus; and Gd-BOPTA: 1.5 mL, 3.0 mL, and 6.0 mL with 0.8 mL prebolus. Pulmonary blood flow (PBF), pulmonary distribution volume, and mean transit time were assessed for each bolus. Region of interest measurements were used to determine the arterial input function (AIF) in the pulmonary trunk and signal intensities in lung parenchyma. Two radiologists independently rated the subjective image quality of the quantitative perfusion maps based on a 4-point Likert scale. Results: Dose-dependent signal saturation effects were observed for all 3 contrast agents concerning AIF and parenchyma measurements. Signal yields were comparable using Gd-BOPTA (AIF, 214.49 arbitrary units [AU]; parenchyma, 41.7 AU) and Gd-DTPA (207.43 AU; 36.3 AU). Gadofosveset showed significantly lower signal yield (165.74 AU; 25.2 AU; p < 0.008). Highest signal increase was observed for Gd-DTPA. Using Gd-DTPA, mean PBF values for the 3 doses (3 mL, 6 mL, 12 mL) in mL/min per milliliter lung volume were 2.9 ± 1.5, 2.4 ± 1.1, and 1.6 ± 1.0. For the 3 doses of gadofosveset (1.5 mL, 3 mL, 6 mL) mean PBF results were 3.1 ± 1.1, 1.9 ± 0.7, and 1.2 ± 0.6. Last, mean PBF values for Gd-BOPTA (1.5 mL, 3 mL, 6 mL) were 3.4 ± 1.7, 2.8 ± 1.3, and 2.0 ± 0.8. Measurements provided consistent values for all perfusion parameters (PBF, pulmonary distribution volume, mean transit time) when compared with reference literature. Contrast dose volume and the applied contrast agent had no relevant effects on the image quality scores. Conclusions: The dual-bolus approach using a 3D FLASH sequence is a feasible tool for quantitative lung perfusion imaging. Small boluses of 3 mL for Gd-DTPA, 1.5 mL for Gd-BOPTA, and 1.5 mL for gadofosveset provide sufficient signal yield for quantitative parenchyma measurements. Using higher boluses falsely lower perfusion values have to be considered due to signal saturation effects. Although gadofosveset yielded the lowest signal, the generated quantitative perfusion maps were of diagnostic quality. … (more)
- Is Part Of:
- Investigative radiology. Volume 51:Issue 3(2016:Mar.)
- Journal:
- Investigative radiology
- Issue:
- Volume 51:Issue 3(2016:Mar.)
- Issue Display:
- Volume 51, Issue 3 (2016)
- Year:
- 2016
- Volume:
- 51
- Issue:
- 3
- Issue Sort Value:
- 2016-0051-0003-0000
- Page Start:
- Page End:
- Publication Date:
- 2016-03
- Subjects:
- magnetic resonance imaging -- perfusion imaging -- lung -- contrast agents -- comparative study
Diagnosis, Radioscopic -- Periodicals
Radiology, Medical -- Periodicals
616.0757 - Journal URLs:
- http://journals.lww.com/investigativeradiology/pages/default.aspx ↗
http://journals.lww.com ↗ - DOI:
- 10.1097/RLI.0000000000000224 ↗
- Languages:
- English
- ISSNs:
- 0020-9996
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4560.350000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 5213.xml