Fatigue Performance of Cortical Bone Trajectory Screw Compared With Standard Trajectory Pedicle Screw. Issue 6 (March 2016)
- Record Type:
- Journal Article
- Title:
- Fatigue Performance of Cortical Bone Trajectory Screw Compared With Standard Trajectory Pedicle Screw. Issue 6 (March 2016)
- Main Title:
- Fatigue Performance of Cortical Bone Trajectory Screw Compared With Standard Trajectory Pedicle Screw
- Authors:
- Akpolat, Yusuf Tahiri
İnceoğlu, Serkan
Kinne, Nolan
Hunt, Devon
Cheng, Wayne K. - Abstract:
- Abstract : Study Design: Cadaveric biomechanical study. Objective: To determine fatigue behavior of cortical bone trajectory (CBT) pedicle screws. Summary of Background Data: Cortical bone trajectory screws have been becoming popular in spine surgery; however, the long-term fatigue behavior of the new CBT screws remains understudied and limitations not well defined. Methods: Twelve vertebrae from six cadaveric lumbar spines were obtained. After bone mineral density (BMD) measurements, each vertebral body was instrumented with screws from each group, that is, CBT (4.5 × 25 mm) or standard pedicle screw (6.5 × 55 mm). A load (± 4 Nm sagittal bending) was applied under displacement control at 1 Hz. Each construct was loaded for 100 cycles or until 6° of loosening was observed. After fatigue testing, the screws were pulled out axially at 5 mm/min. Results: The standard pedicle screw showed better resistance against 100 cycle loading compared with the CBT screws ( P < 0.001, 6.9°±4.8° vs. 15.2°±5.5°, respectively). The standard pedicle screw testing usually required more than 100 cycles of loading to achieve the critical loosening (3592 ± 4564 cycles), whereas the CBT screw never exceeded 100 cycles (84 ± 24 cycles) ( P = 0.002). Increased BMD was significantly associated with a higher number of cycles and less loosening. The standard pedicle screw group had a higher postfatigue pullout load than the CBT screw group ( P = 0.001, 776 ± 370 N and 302 ± 232 N, respectively).Abstract : Study Design: Cadaveric biomechanical study. Objective: To determine fatigue behavior of cortical bone trajectory (CBT) pedicle screws. Summary of Background Data: Cortical bone trajectory screws have been becoming popular in spine surgery; however, the long-term fatigue behavior of the new CBT screws remains understudied and limitations not well defined. Methods: Twelve vertebrae from six cadaveric lumbar spines were obtained. After bone mineral density (BMD) measurements, each vertebral body was instrumented with screws from each group, that is, CBT (4.5 × 25 mm) or standard pedicle screw (6.5 × 55 mm). A load (± 4 Nm sagittal bending) was applied under displacement control at 1 Hz. Each construct was loaded for 100 cycles or until 6° of loosening was observed. After fatigue testing, the screws were pulled out axially at 5 mm/min. Results: The standard pedicle screw showed better resistance against 100 cycle loading compared with the CBT screws ( P < 0.001, 6.9°±4.8° vs. 15.2°±5.5°, respectively). The standard pedicle screw testing usually required more than 100 cycles of loading to achieve the critical loosening (3592 ± 4564 cycles), whereas the CBT screw never exceeded 100 cycles (84 ± 24 cycles) ( P = 0.002). Increased BMD was significantly associated with a higher number of cycles and less loosening. The standard pedicle screw group had a higher postfatigue pullout load than the CBT screw group ( P = 0.001, 776 ± 370 N and 302 ± 232 N, respectively). Conclusion: The standard pedicle screw had a better fatigue performance compared witho the CBT screw in vertebra with compromised bone quality. The proper insertion of the CBT screw might be prevented by the laminar anatomy depending on the screw head design. The CBT screw damaged the bone along its shaft by rotating around a fulcrum, located at either the pars, pedicle isthmus, or the junction of the pedicle and superior endplate, contingent upon the strength of the bone. Level of Evidence: N/A … (more)
- Is Part Of:
- Spine. Volume 41:Issue 6(2016)
- Journal:
- Spine
- Issue:
- Volume 41:Issue 6(2016)
- Issue Display:
- Volume 41, Issue 6 (2016)
- Year:
- 2016
- Volume:
- 41
- Issue:
- 6
- Issue Sort Value:
- 2016-0041-0006-0000
- Page Start:
- Page End:
- Publication Date:
- 2016-03
- Subjects:
- biomechanics -- cortical bone trajectory -- cortical screw -- fatigue testing -- pedicle screw -- pullout testing -- strength -- traditional trajectory
Spine -- Abnormalities -- Periodicals
Spine -- Diseases -- Periodicals
Spine -- Surgery -- Periodicals
616.73005 - Journal URLs:
- http://gateway.ovid.com/ovidweb.cgi?T=JS&MODE=ovid&NEWS=n&PAGE=toc&D=ovft&AN=00007632-000000000-00000 ↗
http://journals.lww.com/spinejournal/pages/default.aspx ↗
http://www.spinejournal.com/ ↗
http://journals.lww.com ↗ - DOI:
- 10.1097/BRS.0000000000001233 ↗
- Languages:
- English
- ISSNs:
- 0362-2436
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 8413.903000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 5222.xml