In Vitro and In Vivo Assessment of Nonionic Iodinated Radiographic Molecules as Chemical Exchange Saturation Transfer Magnetic Resonance Imaging Tumor Perfusion Agents. Issue 3 (March 2016)
- Record Type:
- Journal Article
- Title:
- In Vitro and In Vivo Assessment of Nonionic Iodinated Radiographic Molecules as Chemical Exchange Saturation Transfer Magnetic Resonance Imaging Tumor Perfusion Agents. Issue 3 (March 2016)
- Main Title:
- In Vitro and In Vivo Assessment of Nonionic Iodinated Radiographic Molecules as Chemical Exchange Saturation Transfer Magnetic Resonance Imaging Tumor Perfusion Agents
- Authors:
- Longo, Dario Livio
Michelotti, Filippo
Consolino, Lorena
Bardini, Paola
Digilio, Giuseppe
Xiao, Gang
Sun, Phillip Zhe
Aime, Silvio - Abstract:
- Abstract : Objectives: The aim of this study was to evaluate 4 nonionic x-ray iodinated contrast agents (CAs), commonly used in radiographic procedures, as novel chemical exchange saturation transfer (CEST) magnetic resonance imaging (MRI) agents by assessing their in vitro exchange properties and preliminary in vivo use as tumor enhancing agents. Materials and Methods: The CEST properties, as function of pH (range, 5.5–7.9) and of radio frequency conditions (irradiation field strength range of 1–9 μT and time of 1–9 seconds), have been determined at 7 T and 310 K for 4 x-ray CAs commonly used in clinical settings, namely, iomeprol, iohexol, ioversol, and iodixanol. Their in vivo properties have been investigated upon intravenous injection in a murine HER2+ breast tumor model (n = 4 mice for each CA) using both computed tomography (CT) and MRI modalities. Results: The prototropic exchange rates measured for the 4 investigated iodinated molecules showed strong pH dependence with base catalyzed exchange rate that was faster for monomeric compounds (20–4000 Hz in the pH range of 5.5–7.9). Computed tomography quantification showed marked (up to 2 mg I/mL concentration) and prolonged accumulation (up to 30 minutes postinjection) inside tumor regions. Among the 4 agents we tested, iohexol and ioversol display good CEST contrast properties at 7 T, and in vivo results confirmed strong and prolonged contrast enhancement of the tumors, with elevated extravasation fractions (74%–91%).Abstract : Objectives: The aim of this study was to evaluate 4 nonionic x-ray iodinated contrast agents (CAs), commonly used in radiographic procedures, as novel chemical exchange saturation transfer (CEST) magnetic resonance imaging (MRI) agents by assessing their in vitro exchange properties and preliminary in vivo use as tumor enhancing agents. Materials and Methods: The CEST properties, as function of pH (range, 5.5–7.9) and of radio frequency conditions (irradiation field strength range of 1–9 μT and time of 1–9 seconds), have been determined at 7 T and 310 K for 4 x-ray CAs commonly used in clinical settings, namely, iomeprol, iohexol, ioversol, and iodixanol. Their in vivo properties have been investigated upon intravenous injection in a murine HER2+ breast tumor model (n = 4 mice for each CA) using both computed tomography (CT) and MRI modalities. Results: The prototropic exchange rates measured for the 4 investigated iodinated molecules showed strong pH dependence with base catalyzed exchange rate that was faster for monomeric compounds (20–4000 Hz in the pH range of 5.5–7.9). Computed tomography quantification showed marked (up to 2 mg I/mL concentration) and prolonged accumulation (up to 30 minutes postinjection) inside tumor regions. Among the 4 agents we tested, iohexol and ioversol display good CEST contrast properties at 7 T, and in vivo results confirmed strong and prolonged contrast enhancement of the tumors, with elevated extravasation fractions (74%–91%). A strong and significant correlation was found between CT and CEST-MRI tumor-enhanced images ( R 2 = 0.70, P < 0.01). Conclusions: The obtained results demonstrate that iohexol and ioversol, 2 commonly used radiographic compounds, can be used as MRI perfusion agents, particularly useful when serial images acquisitions are needed to complement CT information. … (more)
- Is Part Of:
- Investigative radiology. Volume 51:Issue 3(2016:Mar.)
- Journal:
- Investigative radiology
- Issue:
- Volume 51:Issue 3(2016:Mar.)
- Issue Display:
- Volume 51, Issue 3 (2016)
- Year:
- 2016
- Volume:
- 51
- Issue:
- 3
- Issue Sort Value:
- 2016-0051-0003-0000
- Page Start:
- Page End:
- Publication Date:
- 2016-03
- Subjects:
- CEST -- MRI -- x-ray -- CT -- iohexol -- ioversol -- iodixanol -- iomeprol -- contrast agents -- tumor
Diagnosis, Radioscopic -- Periodicals
Radiology, Medical -- Periodicals
616.0757 - Journal URLs:
- http://journals.lww.com/investigativeradiology/pages/default.aspx ↗
http://journals.lww.com ↗ - DOI:
- 10.1097/RLI.0000000000000217 ↗
- Languages:
- English
- ISSNs:
- 0020-9996
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4560.350000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 5213.xml