Energy, exergy and thermoeconomic analysis of a novel combined cooling and power system using low-temperature heat source and LNG cold energy recovery. (15th October 2017)
- Record Type:
- Journal Article
- Title:
- Energy, exergy and thermoeconomic analysis of a novel combined cooling and power system using low-temperature heat source and LNG cold energy recovery. (15th October 2017)
- Main Title:
- Energy, exergy and thermoeconomic analysis of a novel combined cooling and power system using low-temperature heat source and LNG cold energy recovery
- Authors:
- Ghaebi, Hadi
Parikhani, Towhid
Rostamzadeh, Hadi - Abstract:
- Highlights: A combined cooling and power cycle using low-temperature heat source and LNG cold energy was proposed. Energy, exergy, and exergoeconomic analyses of the proposed cycle were carried out. Comprehensive parametric study of some key parameters was performed. Abstract: This paper deals with the energy, exergy, and economic analysis of a novel ammonia-water combined cooling and power cycle using waste heat as low-temperature heat source and LNG cold energy as thermal sink. For this purpose, thermodynamic modeling of the proposed system is presented and the performance of the cycle is investigated based on the following performance criteria: net power output, cooling output, first-law efficiency, second-law efficiency, and sum unit cost of the products (SUCPs) of the system. In this respect, the simulation revealed that the net power output, cooling output, first-law efficiency, second-law efficiency, and total SUCP of the system can be calculated 1379 kW, 1736 kW, 43.25%, 22.51%, and 133.7 $/GJ, respectively, showing a considerable enhancement through this integration. In addition, the irreversibility of each component and overall system are presented showing that heat exchanger 2 accounts for the highest exergy destruction among all components which is followed by the throttling valve 1. Moreover, a comprehensive parametric study is conducted to investigate the effects of considered key parameters, namely, vapor generator pressure, LNG turbine inlet pressure,Highlights: A combined cooling and power cycle using low-temperature heat source and LNG cold energy was proposed. Energy, exergy, and exergoeconomic analyses of the proposed cycle were carried out. Comprehensive parametric study of some key parameters was performed. Abstract: This paper deals with the energy, exergy, and economic analysis of a novel ammonia-water combined cooling and power cycle using waste heat as low-temperature heat source and LNG cold energy as thermal sink. For this purpose, thermodynamic modeling of the proposed system is presented and the performance of the cycle is investigated based on the following performance criteria: net power output, cooling output, first-law efficiency, second-law efficiency, and sum unit cost of the products (SUCPs) of the system. In this respect, the simulation revealed that the net power output, cooling output, first-law efficiency, second-law efficiency, and total SUCP of the system can be calculated 1379 kW, 1736 kW, 43.25%, 22.51%, and 133.7 $/GJ, respectively, showing a considerable enhancement through this integration. In addition, the irreversibility of each component and overall system are presented showing that heat exchanger 2 accounts for the highest exergy destruction among all components which is followed by the throttling valve 1. Moreover, a comprehensive parametric study is conducted to investigate the effects of considered key parameters, namely, vapor generator pressure, LNG turbine inlet pressure, evaporator temperature, condenser temperature, heat source temperature, and ammonia concentration on the performance criteria. It is observed that one can obtain a higher first-law efficiency at higher ammonia concentrations, heat source temperatures and LNG turbine inlet pressures or at lower condenser temperatures and vapor generator pressures, while a higher second-law efficiency can be obtained at lower ammonia concentrations, heat source temperatures and condenser temperatures or at higher vapor generator pressures, evaporator temperatures as well as LNG turbine inlet pressures. … (more)
- Is Part Of:
- Energy conversion and management. Volume 150(2017)
- Journal:
- Energy conversion and management
- Issue:
- Volume 150(2017)
- Issue Display:
- Volume 150, Issue 2017 (2017)
- Year:
- 2017
- Volume:
- 150
- Issue:
- 2017
- Issue Sort Value:
- 2017-0150-2017-0000
- Page Start:
- 678
- Page End:
- 692
- Publication Date:
- 2017-10-15
- Subjects:
- Cogeneration -- LNG -- Low-temperature heat source -- Energy analysis -- Exergy analysis -- Exergoeconomic analysis
Direct energy conversion -- Periodicals
Energy storage -- Periodicals
Energy transfer -- Periodicals
Énergie -- Conversion directe -- Périodiques
Direct energy conversion
Periodicals
621.3105 - Journal URLs:
- http://www.sciencedirect.com/science/journal/01968904 ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.enconman.2017.08.052 ↗
- Languages:
- English
- ISSNs:
- 0196-8904
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3747.547000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 5191.xml