Refining Target-Controlled Infusion: An Assessment of Pharmacodynamic Target-Controlled Infusion of Propofol and Remifentanil Using a Response Surface Model of Their Combined Effects on Bispectral Index. (January 2016)
- Record Type:
- Journal Article
- Title:
- Refining Target-Controlled Infusion: An Assessment of Pharmacodynamic Target-Controlled Infusion of Propofol and Remifentanil Using a Response Surface Model of Their Combined Effects on Bispectral Index. (January 2016)
- Main Title:
- Refining Target-Controlled Infusion
- Authors:
- Short, Timothy G.
Hannam, Jacqueline A.
Laurent, Stephen
Campbell, Douglas
Misur, Martin
Merry, Alan F.
Tam, Yuk Ho - Abstract:
- Abstract : BACKGROUND: Propofol and remifentanil are commonly combined for total IV anesthesia. The pharmacokinetics (PK), pharmacodynamics (PD), and drug interactions of the combination are well understood, but the use of a combined PK and PD model to control target-controlled infusion pumps has not been investigated. In this study, we prospectively tested the accuracy of a PD target-controlled infusion algorithm for propofol and remifentanil using a response surface model of their combined effects on Bispectral Index (BIS). METHODS: Effect-site, target-controlled infusions of propofol and remifentanil were given using an algorithm based on standard PK models linked to a PD response surface model of their combined effects on BIS. The combination of a targeted BIS value and adjustable ratio of propofol to remifentanil was used to adjust infusion rates. The standard model performance measures of median performance error (bias) and median absolute performance error (inaccuracy), expressed as percentages, were used to assess accuracy of the infusions in a convenience sample of 50 adult patients undergoing surgery with general anesthesia. The influence of age and weight on the performance of the model was also assessed. RESULTS: Patients had a mean (range) age of 48 (19–73) years, weight of 80 (45–169) kg, and body mass index of 28 (19–45) kg/m 2 . The overall model had a bias of 8% (SD 24%) and inaccuracy of 25% (SD 13%). Performance was least accurate during the earlyAbstract : BACKGROUND: Propofol and remifentanil are commonly combined for total IV anesthesia. The pharmacokinetics (PK), pharmacodynamics (PD), and drug interactions of the combination are well understood, but the use of a combined PK and PD model to control target-controlled infusion pumps has not been investigated. In this study, we prospectively tested the accuracy of a PD target-controlled infusion algorithm for propofol and remifentanil using a response surface model of their combined effects on Bispectral Index (BIS). METHODS: Effect-site, target-controlled infusions of propofol and remifentanil were given using an algorithm based on standard PK models linked to a PD response surface model of their combined effects on BIS. The combination of a targeted BIS value and adjustable ratio of propofol to remifentanil was used to adjust infusion rates. The standard model performance measures of median performance error (bias) and median absolute performance error (inaccuracy), expressed as percentages, were used to assess accuracy of the infusions in a convenience sample of 50 adult patients undergoing surgery with general anesthesia. The influence of age and weight on the performance of the model was also assessed. RESULTS: Patients had a mean (range) age of 48 (19–73) years, weight of 80 (45–169) kg, and body mass index of 28 (19–45) kg/m 2 . The overall model had a bias of 8% (SD 24%) and inaccuracy of 25% (SD 13%). Performance was least accurate during the early induction phase of anesthesia. There was no significant bias in BIS predictions with increasing age ( P = 0.44) or weight ( P = 0.56). CONCLUSIONS: The algorithm performed adequately in a clinical setting. The algorithm could be further refined, and assessment of its accuracy and utility in comparison to current clinical practice for giving IV anesthesia is warranted. Abstract : Supplemental Digital Content is available in the text.Published ahead of print September 2, 2015 … (more)
- Is Part Of:
- Anesthesia & analgesia. Volume 122:Number 1(2016)
- Journal:
- Anesthesia & analgesia
- Issue:
- Volume 122:Number 1(2016)
- Issue Display:
- Volume 122, Issue 1 (2016)
- Year:
- 2016
- Volume:
- 122
- Issue:
- 1
- Issue Sort Value:
- 2016-0122-0001-0000
- Page Start:
- Page End:
- Publication Date:
- 2016-01
- Subjects:
- Anesthesiology -- Periodicals
Anesthesia
Anesthesiology
Analgesia
Analgesics
Anesthesiology -- Periodicals
617.9605 - Journal URLs:
- http://gateway.ovid.com/ovidweb.cgi?T=JS&MODE=ovid&PAGE=toc&D=ovft&AN=00000539-000000000-00000 ↗
http://journals.lww.com/anesthesia-analgesia/Pages/default.aspx ↗
http://www.anesthesia-analgesia.org ↗
http://journals.lww.com ↗ - DOI:
- 10.1213/ANE.0000000000000386 ↗
- Languages:
- English
- ISSNs:
- 0003-2999
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 0900.500000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 5191.xml