The Influence of Plasma Albumin Concentration on the Analysis Methodology of Free Valproic Acid by Ultrafiltration and Its Application to Therapeutic Drug Monitoring. Issue 6 (December 2015)
- Record Type:
- Journal Article
- Title:
- The Influence of Plasma Albumin Concentration on the Analysis Methodology of Free Valproic Acid by Ultrafiltration and Its Application to Therapeutic Drug Monitoring. Issue 6 (December 2015)
- Main Title:
- The Influence of Plasma Albumin Concentration on the Analysis Methodology of Free Valproic Acid by Ultrafiltration and Its Application to Therapeutic Drug Monitoring
- Authors:
- Zhang, Zhi-qing
Dong, Wei-chong
Yang, Xiu-ling
Zhang, Jin-feng
Jiang, Xin-Hui
Jing, Shao-jun
Yang, Hong-le
Jiang, Ye - Abstract:
- Abstract : Background: Free drug analysis is increasingly becoming popular in therapeutic drug monitoring (TDM). Centrifugal ultrafiltration (CF-UF) is the primary method to separate free drug from that of bound drug. However, the volume ratio of ultrafiltrate to sample solution ( V u / V s ) affects the accuracy of CF-UF, which highly depends on the different plasma conditions. Plasma protein concentrations in patients are different from those observed in healthy subjects, and there are also significant differences among patients with different diseases. Only very few studies have reported on the effect of protein concentration on the analysis methodology of free drug by CF-UF. Methods: In this study, valproic acid was used as the representative drug, and plasma samples with different albumin concentrations were analyzed by CF-UF and hollow fiber centrifugal ultrafiltration (HFCF-UF). Results: There was no significant difference of free drug concentrations by HFCF-UF and CF-UF when plasma albumin concentrations ranged 40–60 g/L. However, at low albumin concentrations (<40 g/L), a considerable difference was detected, and the difference was increased with the decrease of plasma albumin concentration. When the albumin concentration was as low as 10 g/L, the free drug concentration was 17.3 mcg/mL by CF-UF, whereas it was 10.2 mcg/mL by HFCF-UF. Conclusions: The accuracy of free drug measurement by CF-UF was albumin concentration dependent. However, such an effect was notAbstract : Background: Free drug analysis is increasingly becoming popular in therapeutic drug monitoring (TDM). Centrifugal ultrafiltration (CF-UF) is the primary method to separate free drug from that of bound drug. However, the volume ratio of ultrafiltrate to sample solution ( V u / V s ) affects the accuracy of CF-UF, which highly depends on the different plasma conditions. Plasma protein concentrations in patients are different from those observed in healthy subjects, and there are also significant differences among patients with different diseases. Only very few studies have reported on the effect of protein concentration on the analysis methodology of free drug by CF-UF. Methods: In this study, valproic acid was used as the representative drug, and plasma samples with different albumin concentrations were analyzed by CF-UF and hollow fiber centrifugal ultrafiltration (HFCF-UF). Results: There was no significant difference of free drug concentrations by HFCF-UF and CF-UF when plasma albumin concentrations ranged 40–60 g/L. However, at low albumin concentrations (<40 g/L), a considerable difference was detected, and the difference was increased with the decrease of plasma albumin concentration. When the albumin concentration was as low as 10 g/L, the free drug concentration was 17.3 mcg/mL by CF-UF, whereas it was 10.2 mcg/mL by HFCF-UF. Conclusions: The accuracy of free drug measurement by CF-UF was albumin concentration dependent. However, such an effect was not observed when samples were prepared by HFCF-UF, which was more suitable for TDM of plasma samples from different patients. Therefore, this method could be readily applied to the measurement of free valproic acid plasma concentrations for TDM in patients. Abstract : Supplemental Digital Content is Available in the Text. … (more)
- Is Part Of:
- Therapeutic drug monitoring. Volume 37:Issue 6(2015:Dec.)
- Journal:
- Therapeutic drug monitoring
- Issue:
- Volume 37:Issue 6(2015:Dec.)
- Issue Display:
- Volume 37, Issue 6 (2015)
- Year:
- 2015
- Volume:
- 37
- Issue:
- 6
- Issue Sort Value:
- 2015-0037-0006-0000
- Page Start:
- Page End:
- Publication Date:
- 2015-12
- Subjects:
- plasma protein concentration -- free drug concentration -- hollow fiber centrifugal ultrafiltration -- therapeutic drug monitoring -- valproic acid
Pharmacokinetics -- Periodicals
Patient monitoring -- Periodicals
Drugs -- Analysis -- Periodicals
Body fluids -- Analysis -- Periodicals
Drug Therapy -- Periodicals
Monitoring, Physiologic -- Periodicals
Pharmacology -- Periodicals
615.7 - Journal URLs:
- http://journals.lww.com/drug-monitoring/pages/default.aspx ↗
http://ovidsp.ovid.com/ovidweb.cgi?T=JS&NEWS=n&CSC=Y&PAGE=toc&D=yrovft&AN=00007691-000000000-00000 ↗
http://www.drug-monitoring.com/ ↗
http://journals.lww.com ↗
http://www.lww.com/Product/0163-4356 ↗ - DOI:
- 10.1097/FTD.0000000000000225 ↗
- Languages:
- English
- ISSNs:
- 0163-4356
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 8814.643000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 5191.xml