Factors Affecting the Nonlinear Force Versus Distraction Height Curves in an In Vitro C5–C6 Anterior Cervical Distraction Model. Issue 5 (June 2017)
- Record Type:
- Journal Article
- Title:
- Factors Affecting the Nonlinear Force Versus Distraction Height Curves in an In Vitro C5–C6 Anterior Cervical Distraction Model. Issue 5 (June 2017)
- Main Title:
- Factors Affecting the Nonlinear Force Versus Distraction Height Curves in an In Vitro C5–C6 Anterior Cervical Distraction Model
- Authors:
- Wen, Junxiang
Xu, Jianwei
Li, Lijun
Yang, Mingjie
Pan, Jie
Chen, Deyu
Jia, Lianshun
Tan, Jun - Abstract:
- Abstract : Study Design: In vitro biomechanical study of cervical intervertebral distraction. Objective: To investigate the forces required for distraction to different heights in an in vitro C5–C6 anterior cervical distraction model, focusing on the influence of the intervertebral disk, posterior longitudinal ligament (PLL), and ligamentum flavum (LF). Summary of Background Data: No previous studies have reported on the forces required for distraction to various heights or the factors resisting distraction in anterior cervical discectomy and fusion. Materials and Methods: Anterior cervical distraction at C5–C6 was performed in 6 cadaveric specimens using a biomechanical testing machine, under 4 conditions: A, before disk removal; B, after disk removal; C, after disk and PLL removal; and D, after disk and PLL removal and cutting of the LF. Distraction was performed from 0 to 10 mm at a constant velocity (5 mm/min). Force and distraction height were recorded automatically. Results: The force required increased with distraction height under all 4 conditions. There was a sudden increase in force required at 6–7 mm under conditions B and C, but not D. Under condition A, distraction to 5 mm required a force of 268.3±38.87 N. Under conditions B and C, distraction to 6 mm required <15 N, and further distraction required dramatically increased force, with distraction to 10 mm requiring 115.4±10.67 and 68.4±9.67 N, respectively. Under condition D, no marked increase in force wasAbstract : Study Design: In vitro biomechanical study of cervical intervertebral distraction. Objective: To investigate the forces required for distraction to different heights in an in vitro C5–C6 anterior cervical distraction model, focusing on the influence of the intervertebral disk, posterior longitudinal ligament (PLL), and ligamentum flavum (LF). Summary of Background Data: No previous studies have reported on the forces required for distraction to various heights or the factors resisting distraction in anterior cervical discectomy and fusion. Materials and Methods: Anterior cervical distraction at C5–C6 was performed in 6 cadaveric specimens using a biomechanical testing machine, under 4 conditions: A, before disk removal; B, after disk removal; C, after disk and PLL removal; and D, after disk and PLL removal and cutting of the LF. Distraction was performed from 0 to 10 mm at a constant velocity (5 mm/min). Force and distraction height were recorded automatically. Results: The force required increased with distraction height under all 4 conditions. There was a sudden increase in force required at 6–7 mm under conditions B and C, but not D. Under condition A, distraction to 5 mm required a force of 268.3±38.87 N. Under conditions B and C, distraction to 6 mm required <15 N, and further distraction required dramatically increased force, with distraction to 10 mm requiring 115.4±10.67 and 68.4±9.67 N, respectively. Under condition D, no marked increase in force was recorded. Conclusions: Distraction of the intervertebral space was much easier after disk removal. An intact LF caused a sudden marked increase in the force required for distraction, possibly indicating the point at which the LF was fully stretched. This increase in resistance may help to determine the optimal distraction height to avoid stress to the endplate spacer. … (more)
- Is Part Of:
- Clinical spine surgery. Volume 30:Issue 5(2017)
- Journal:
- Clinical spine surgery
- Issue:
- Volume 30:Issue 5(2017)
- Issue Display:
- Volume 30, Issue 5 (2017)
- Year:
- 2017
- Volume:
- 30
- Issue:
- 5
- Issue Sort Value:
- 2017-0030-0005-0000
- Page Start:
- Page End:
- Publication Date:
- 2017-06
- Subjects:
- discectomy -- distraction -- disc -- ligamentum flavum -- biomechanics
Spinal cord -- Diseases -- Periodicals
Spinal cord -- Surgery -- Periodicals
617.56059 - Journal URLs:
- http://journals.lww.com/pages/default.aspx ↗
http://journals.lww.com/jspinaldisorders/pages/default.aspx ↗ - DOI:
- 10.1097/BSD.0000000000000160 ↗
- Languages:
- English
- ISSNs:
- 2380-0186
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3286.382100
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 5170.xml