ProSeal Laryngeal Mask Airway Attenuates Systemic and Cerebral Hemodynamic Response During Awakening of Neurosurgical Patients: A Randomized Clinical Trial. Issue 3 (July 2015)
- Record Type:
- Journal Article
- Title:
- ProSeal Laryngeal Mask Airway Attenuates Systemic and Cerebral Hemodynamic Response During Awakening of Neurosurgical Patients: A Randomized Clinical Trial. Issue 3 (July 2015)
- Main Title:
- ProSeal Laryngeal Mask Airway Attenuates Systemic and Cerebral Hemodynamic Response During Awakening of Neurosurgical Patients
- Authors:
- Perelló-Cerdà, Laura
Fàbregas, Neus
López, Ana M.
Rios, José
Tercero, Javier
Carrero, Enrique
Hurtado, Paola
Hervías, Adriana
Gracia, Isabel
Caral, Luis
de Riva, Nicolás
Valero, Ricard - Abstract:
- Abstract : Background: Extubation and emergence from anesthesia may lead to systemic and cerebral hemodynamic changes that endanger neurosurgical patients. We aimed to compare systemic and cerebral hemodynamic variables and cough incidence in neurosurgery patients emerging from general anesthesia with the standard procedure (endotracheal tube [ETT] extubation) or after replacement of the ETT with a laryngeal mask airway (LMA). Materials and Methods: Forty-two patients undergoing supratentorial craniotomy under general anesthesia were included in a randomized open-label parallel trial. Patients were randomized (sealed envelopes labeled with software-generated randomized numbers) to awaken with the ETT in place or after its replacement with a ProSeal LMA. We recorded mean arterial pressure as the primary endpoint and heart rate, middle cerebral artery flow velocity, regional cerebral oxygen saturation, norepinephrine plasma concentrations, and coughing. Results: No differences were found between groups at baseline. All hemodynamic variables increased significantly from baseline in both groups during emergence. The ETT group had significantly higher mean arterial pressure (11.9 mm Hg; 95% confidence interval [CI], 2.1-21.8 mm Hg) ( P =0.017), heart rate (7.2 beats/min; 95% CI, 0.7-13.7 beats/min) ( P =0.03), and rate-pressure product (1045.4; 95% CI, 440.8-1650) ( P =0.001). Antihypertensive medication was administered to more ETT-group patients than LMA-group patients (9Abstract : Background: Extubation and emergence from anesthesia may lead to systemic and cerebral hemodynamic changes that endanger neurosurgical patients. We aimed to compare systemic and cerebral hemodynamic variables and cough incidence in neurosurgery patients emerging from general anesthesia with the standard procedure (endotracheal tube [ETT] extubation) or after replacement of the ETT with a laryngeal mask airway (LMA). Materials and Methods: Forty-two patients undergoing supratentorial craniotomy under general anesthesia were included in a randomized open-label parallel trial. Patients were randomized (sealed envelopes labeled with software-generated randomized numbers) to awaken with the ETT in place or after its replacement with a ProSeal LMA. We recorded mean arterial pressure as the primary endpoint and heart rate, middle cerebral artery flow velocity, regional cerebral oxygen saturation, norepinephrine plasma concentrations, and coughing. Results: No differences were found between groups at baseline. All hemodynamic variables increased significantly from baseline in both groups during emergence. The ETT group had significantly higher mean arterial pressure (11.9 mm Hg; 95% confidence interval [CI], 2.1-21.8 mm Hg) ( P =0.017), heart rate (7.2 beats/min; 95% CI, 0.7-13.7 beats/min) ( P =0.03), and rate-pressure product (1045.4; 95% CI, 440.8-1650) ( P =0.001). Antihypertensive medication was administered to more ETT-group patients than LMA-group patients (9 [42.9%] vs. 3 [14.3%] patients, respectively; P =0.04). The percent increase in regional cerebral oxygen saturation was greater in the ETT group by 26.1% (95% CI, 9.1%-43.2%) ( P =0.002), but no between-group differences were found in MCA flow velocity. Norepinephrine plasma concentrations rose in both groups between baseline and the end of emergence: LMA: from 87.5±7.1 to 125.6±17.3 pg/mL; and ETT: from 118.1±14.1 to 158.1±24.7 pg/mL ( P =0.007). The differences between groups were not significant. The incidence of cough was higher in the ETT group (87.5%) than in the LMA group (9.5%) ( P <0.001). Conclusions: Replacing the ETT with the LMA before neurosurgical patients emerge from anesthesia results in a more favorable hemodynamic profile, less cerebral hyperemia, and a lower incidence of cough. … (more)
- Is Part Of:
- Journal of neurosurgical anesthesiology. Volume 27:Issue 3(2015:Jul.)
- Journal:
- Journal of neurosurgical anesthesiology
- Issue:
- Volume 27:Issue 3(2015:Jul.)
- Issue Display:
- Volume 27, Issue 3 (2015)
- Year:
- 2015
- Volume:
- 27
- Issue:
- 3
- Issue Sort Value:
- 2015-0027-0003-0000
- Page Start:
- Page End:
- Publication Date:
- 2015-07
- Subjects:
- laryngeal mask airway -- neurosurgery -- neuroanesthesia -- awakening -- cerebral hemodynamic response -- systemic hemodynamic response -- coughing
Anesthesia in neurology -- Periodicals
Nervous system -- Surgery -- Periodicals
617.96748 - Journal URLs:
- http://journals.lww.com/jnsa/pages/default.aspx ↗
http://journals.lww.com ↗ - DOI:
- 10.1097/ANA.0000000000000108 ↗
- Languages:
- English
- ISSNs:
- 0898-4921
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5022.150000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 5177.xml