Evaluation of Internationally Shipped Prestripped Donor Tissue for Descemet Membrane Endothelial Keratoplasty by Vital Dye Staining. Issue 2 (February 2015)
- Record Type:
- Journal Article
- Title:
- Evaluation of Internationally Shipped Prestripped Donor Tissue for Descemet Membrane Endothelial Keratoplasty by Vital Dye Staining. Issue 2 (February 2015)
- Main Title:
- Evaluation of Internationally Shipped Prestripped Donor Tissue for Descemet Membrane Endothelial Keratoplasty by Vital Dye Staining
- Authors:
- Kobayashi, Akira
Murata, Noriaki
Yokogawa, Hideaki
Yamazaki, Natsuko
Masaki, Toshinori
Sugiyama, Kazuhisa - Abstract:
- Abstract : Purpose: The aim of this study was to evaluate endothelial cell damage of internationally shipped prestripped donor tissue for Descemet membrane endothelial keratoplasty (DMEK) using vital dye staining. Methods: Six internationally shipped prestripped DMEK donors were stained with trypan blue and were subsequently photographed before they were cut with a trephine. Quantitative analysis assessment of endothelial damage of the donor graft area (8.0 mm in diameter) was performed using Adobe Photoshop CS6 Extended software. Seven internationally shipped precut Descemet stripping automated endothelial keratoplasty (DSAEK) donors were used as controls. Results: No statistical differences were noted between prestripped DMEK donors and precut DSAEK donors in mean donor age (67.7 vs. 56.4 years, P = 0.222), mean donor endothelial cell density (2687.3 vs. 2894.6 cells, P = 0.353), and death-to-preservation time (405.3 vs. 558.4 minutes, P = 0.173). However, the mean time of death-to-experiment time in DMEK donors was significantly longer than that of DSAEK donors (8.7 vs. 6.6 days, P = 0.031). Mean endothelial cell damage of prestripped DMEK donors was as low as 0.3%. However, DMEK donor endothelial damage (0.3%) was significantly higher compared with that of precut DSAEK donor tissue (0.01%, P = 0.029). Conclusions: Although endothelial damage of internationally shipped prestripped donor tissue for DMEK was higher than that of precut DSAEK donor, it was extremely low.Abstract : Purpose: The aim of this study was to evaluate endothelial cell damage of internationally shipped prestripped donor tissue for Descemet membrane endothelial keratoplasty (DMEK) using vital dye staining. Methods: Six internationally shipped prestripped DMEK donors were stained with trypan blue and were subsequently photographed before they were cut with a trephine. Quantitative analysis assessment of endothelial damage of the donor graft area (8.0 mm in diameter) was performed using Adobe Photoshop CS6 Extended software. Seven internationally shipped precut Descemet stripping automated endothelial keratoplasty (DSAEK) donors were used as controls. Results: No statistical differences were noted between prestripped DMEK donors and precut DSAEK donors in mean donor age (67.7 vs. 56.4 years, P = 0.222), mean donor endothelial cell density (2687.3 vs. 2894.6 cells, P = 0.353), and death-to-preservation time (405.3 vs. 558.4 minutes, P = 0.173). However, the mean time of death-to-experiment time in DMEK donors was significantly longer than that of DSAEK donors (8.7 vs. 6.6 days, P = 0.031). Mean endothelial cell damage of prestripped DMEK donors was as low as 0.3%. However, DMEK donor endothelial damage (0.3%) was significantly higher compared with that of precut DSAEK donor tissue (0.01%, P = 0.029). Conclusions: Although endothelial damage of internationally shipped prestripped donor tissue for DMEK was higher than that of precut DSAEK donor, it was extremely low. Further evaluation using another vital dye and clinical studies may be needed to confirm this study. … (more)
- Is Part Of:
- Cornea. Volume 34:Issue 2(2015)
- Journal:
- Cornea
- Issue:
- Volume 34:Issue 2(2015)
- Issue Display:
- Volume 34, Issue 2 (2015)
- Year:
- 2015
- Volume:
- 34
- Issue:
- 2
- Issue Sort Value:
- 2015-0034-0002-0000
- Page Start:
- Page End:
- Publication Date:
- 2015-02
- Subjects:
- Descemet stripping automated endothelial keratoplasty -- Descemet membrane endothelial keratoplasty -- endothelial damage -- trypan blue
Cornea -- Periodicals
Cornea -- Periodicals
Cornée -- Périodiques
617.719 - Journal URLs:
- http://journals.lww.com/corneajrnl/pages/default.aspx ↗
http://journals.lww.com ↗ - DOI:
- 10.1097/ICO.0000000000000330 ↗
- Languages:
- English
- ISSNs:
- 0277-3740
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3470.927500
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 5182.xml