Femtosecond Laser Cutting of Endothelial Grafts: Comparison of Endothelial and Epithelial Applanation. Issue 2 (February 2015)
- Record Type:
- Journal Article
- Title:
- Femtosecond Laser Cutting of Endothelial Grafts: Comparison of Endothelial and Epithelial Applanation. Issue 2 (February 2015)
- Main Title:
- Femtosecond Laser Cutting of Endothelial Grafts
- Authors:
- Bernard, Aurélien
He, Zhiguo
Gauthier, Anne Sophie
Trone, Marie Caroline
Baubeau, Emmanuel
Forest, Fabien
Dumollard, Jean Marc
Peoc'h, Michel
Thuret, Gilles
Gain, Philippe - Abstract:
- Abstract : Purpose: Stromal surface quality of endothelial lamellae cut for endothelial keratoplasty with a femtosecond laser (FSL) with epithelial applanation remains disappointing. Applanation of the endothelial side of the cornea, mounted inverted on an artificial chamber, has therefore been proposed to improve cut quality. We compared lamellar quality after FSL cutting using epithelial versus endothelial applanation. Method: Lamellae were cut with an FSL from organ-cultured corneas. After randomization, 7 were cut with epithelial applanation and 7 with endothelial applanation. Lamellae of 50-, 75-, and 100-μm thickness were targeted. Thickness was measured by optical coherence tomography before and immediately after cutting. Viable endothelial cell density was quantified immediately after cutting using triple labeling with Hoechst/ethidium/calcein–AM coupled with image analysis with ImageJ. The stromal surface was evaluated by 9 masked observers using semiquantitative scoring of scanning electronic microscopy images. Histology of 2 samples was also analyzed before lamellar detachment. Results: Precision (difference in target/actual thickness) and thickness regularity [coefficient of variation (CV) of 10 measurements] were significantly better with endothelial applanation (precision: 18 μm; range, 10–30; CV: 11%; range, 8–12) than with epithelial applanation (precision: 84 μm; range, 54–107; P = 0.002; CV: 24%; range, 13–47; P = 0.001). Endothelial applanation providedAbstract : Purpose: Stromal surface quality of endothelial lamellae cut for endothelial keratoplasty with a femtosecond laser (FSL) with epithelial applanation remains disappointing. Applanation of the endothelial side of the cornea, mounted inverted on an artificial chamber, has therefore been proposed to improve cut quality. We compared lamellar quality after FSL cutting using epithelial versus endothelial applanation. Method: Lamellae were cut with an FSL from organ-cultured corneas. After randomization, 7 were cut with epithelial applanation and 7 with endothelial applanation. Lamellae of 50-, 75-, and 100-μm thickness were targeted. Thickness was measured by optical coherence tomography before and immediately after cutting. Viable endothelial cell density was quantified immediately after cutting using triple labeling with Hoechst/ethidium/calcein–AM coupled with image analysis with ImageJ. The stromal surface was evaluated by 9 masked observers using semiquantitative scoring of scanning electronic microscopy images. Histology of 2 samples was also analyzed before lamellar detachment. Results: Precision (difference in target/actual thickness) and thickness regularity [coefficient of variation (CV) of 10 measurements] were significantly better with endothelial applanation (precision: 18 μm; range, 10–30; CV: 11%; range, 8–12) than with epithelial applanation (precision: 84 μm; range, 54–107; P = 0.002; CV: 24%; range, 13–47; P = 0.001). Endothelial applanation provided thinner lamellae. However, viable endothelial cell density was significantly lower after endothelial applanation (1183 cells/mm 2 ; range, 787–1725 versus 1688 cells/mm 2 ; range, 1288–2025; P = 0.018). Conclusions: FSL cutting of endothelial lamellae using endothelial applanation provides thinner more regular grafts with more predictable thickness than with conventional epithelial applanation but strongly reduces the pool of viable endothelial cells. … (more)
- Is Part Of:
- Cornea. Volume 34:Issue 2(2015)
- Journal:
- Cornea
- Issue:
- Volume 34:Issue 2(2015)
- Issue Display:
- Volume 34, Issue 2 (2015)
- Year:
- 2015
- Volume:
- 34
- Issue:
- 2
- Issue Sort Value:
- 2015-0034-0002-0000
- Page Start:
- Page End:
- Publication Date:
- 2015-02
- Subjects:
- cornea -- human -- microkeratome -- femtosecond laser -- endothelium -- graft -- quality -- viability -- applanation
Cornea -- Periodicals
Cornea -- Periodicals
Cornée -- Périodiques
617.719 - Journal URLs:
- http://journals.lww.com/corneajrnl/pages/default.aspx ↗
http://journals.lww.com ↗ - DOI:
- 10.1097/ICO.0000000000000314 ↗
- Languages:
- English
- ISSNs:
- 0277-3740
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3470.927500
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 5183.xml