Rigid Gas Permeable Contact Lens Fitting Using New Software in Keratoconic Eyes. Issue 3 (March 2016)
- Record Type:
- Journal Article
- Title:
- Rigid Gas Permeable Contact Lens Fitting Using New Software in Keratoconic Eyes. Issue 3 (March 2016)
- Main Title:
- Rigid Gas Permeable Contact Lens Fitting Using New Software in Keratoconic Eyes
- Authors:
- Ortiz-Toquero, Sara
Rodriguez, Guadalupe
de Juan, Victoria
Martin, Raul - Abstract:
- ABSTRACT: Purpose: To determine the repeatability of the back optic zone radius (BOZR) of rigid gas permeable (GP) contact lens (CL) proposed by new software for fitting in healthy and keratoconus eyes and to compare with the diagnostic CL fitting method. Methods: Three consecutive corneal topographies (Oculus-Keratograph) were performed and analyzed with APEX new software CL fitting (Hecht-Contactlinsen, Germany) in 40 healthy and 40 keratoconus eyes fitted with GP using conventional diagnostic method. The coefficient of variation (CV) of the BOZR suggested by APEX was calculated. The BOZR of both fitting methods (software versus diagnostic) were compared maintaining the same lens diameter. Results: BOZR proposed by APEX showed good repeatability in healthy (CV = 0.32%) and keratoconus eyes (CV = 0.51%). APEX proposed flatter BOZR than the diagnostic method in healthy (7.91 ± 0.24 and 7.84 ± 0.26 mm, p < 0.01) and keratoconus eyes (7.34 ± 0.38 and 7.23 ± 0.37 mm, p < 0.01). A strong linear correlation in healthy (BOZR_Diagnostic_Method = (BOZR_APEX × 1.06) − 0.53; p < 0.01, R 2 = 0.969) and keratoconus eyes (BOZR_Diagnostic_Method = (BOZR_APEX × 0.88) + 0.77; p < 0.01, R 2 = 0.825) was found. A detailed analysis showed a similar trend in different keratoconus stages (Amsler-Krumeich classification); stage 1: 7.42 ± 0.30 and 7.40 ± 0.25 mm, BOZR_Diagnostic_Method = (BOZR_APEX × 0.81) + 1.38, R 2 = 0.973; stage 2: 7.30 ± 0.44 and 7.23 ± 0.38 mm, BOZR_Diagnostic_Method =ABSTRACT: Purpose: To determine the repeatability of the back optic zone radius (BOZR) of rigid gas permeable (GP) contact lens (CL) proposed by new software for fitting in healthy and keratoconus eyes and to compare with the diagnostic CL fitting method. Methods: Three consecutive corneal topographies (Oculus-Keratograph) were performed and analyzed with APEX new software CL fitting (Hecht-Contactlinsen, Germany) in 40 healthy and 40 keratoconus eyes fitted with GP using conventional diagnostic method. The coefficient of variation (CV) of the BOZR suggested by APEX was calculated. The BOZR of both fitting methods (software versus diagnostic) were compared maintaining the same lens diameter. Results: BOZR proposed by APEX showed good repeatability in healthy (CV = 0.32%) and keratoconus eyes (CV = 0.51%). APEX proposed flatter BOZR than the diagnostic method in healthy (7.91 ± 0.24 and 7.84 ± 0.26 mm, p < 0.01) and keratoconus eyes (7.34 ± 0.38 and 7.23 ± 0.37 mm, p < 0.01). A strong linear correlation in healthy (BOZR_Diagnostic_Method = (BOZR_APEX × 1.06) − 0.53; p < 0.01, R 2 = 0.969) and keratoconus eyes (BOZR_Diagnostic_Method = (BOZR_APEX × 0.88) + 0.77; p < 0.01, R 2 = 0.825) was found. A detailed analysis showed a similar trend in different keratoconus stages (Amsler-Krumeich classification); stage 1: 7.42 ± 0.30 and 7.40 ± 0.25 mm, BOZR_Diagnostic_Method = (BOZR_APEX × 0.81) + 1.38, R 2 = 0.973; stage 2: 7.30 ± 0.44 and 7.23 ± 0.38 mm, BOZR_Diagnostic_Method = (BOZR_APEX × 0.84) + 1.07, R 2 = 0.929; and stage 3: 7.33 ± 0.39 and 7.11 ± 0.40 mm, BOZR_Diagnostic_Method = (BOZR_APEX × 0.93) + 0.28, R 2 = 0.831. Applying these regression formulas, the BOZR difference could be reduced in healthy (−0.01 ± 0.05 mm) and keratoconus eyes (−0.01 ± 0.14 mm) for each keratoconus stage (0.01 ± 0.04, 0.03 ± 0.10, and 0.02 ± 0.16 mm in stages 1, 2, and 3, respectively). Conclusions: APEX software provides repeatable BOZR in healthy and keratoconus eyes, but it tends to propose flatter BOZR than the diagnostic method. APEX BOZR should be improved with new equations and helping with the GP fitting procedure. … (more)
- Is Part Of:
- Optometry and vision science. Volume 93:Issue 3(2016)
- Journal:
- Optometry and vision science
- Issue:
- Volume 93:Issue 3(2016)
- Issue Display:
- Volume 93, Issue 3 (2016)
- Year:
- 2016
- Volume:
- 93
- Issue:
- 3
- Issue Sort Value:
- 2016-0093-0003-0000
- Page Start:
- Page End:
- Publication Date:
- 2016-03
- Subjects:
- keratoconus -- rigid gas permeable -- contact lens fitting software
Optometry -- Periodicals
Physiological optics -- Periodicals
Vision disorders -- Periodicals
617.7505 - Journal URLs:
- http://gateway.ovid.com/ovidweb.cgi?T=JS&MODE=ovid&PAGE=toc&D=ovft&AN=00006324-000000000-00000 ↗
http://www.optvissci.com ↗
http://journals.lww.com ↗ - DOI:
- 10.1097/OPX.0000000000000804 ↗
- Languages:
- English
- ISSNs:
- 1040-5488
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 6276.450000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 5161.xml