MRI Artifacts and Cochlear Implant Positioning at 3 T In Vivo. Issue 6 (July 2015)
- Record Type:
- Journal Article
- Title:
- MRI Artifacts and Cochlear Implant Positioning at 3 T In Vivo. Issue 6 (July 2015)
- Main Title:
- MRI Artifacts and Cochlear Implant Positioning at 3 T In Vivo
- Authors:
- Todt, Ingo
Rademacher, Grit
Mittmann, Philipp
Wagner, Jan
Mutze, Sven
Ernst, Arne - Abstract:
- Abstract : Hypothesis: To evaluate the assessment of the internal auditory canal and the labyrinth in relation to different CI magnet positions and MRI sequences at 3 T. Background: The indication criteria for cochlear implantation have been changed over the years and the growing number of implantations in patients after acoustic neuroma resections underline the importance of a postoperative MR imaging to assess the internal auditory canal (IAC) and the labyrinth. The MRI artifact induced by the cochlear implant magnet is a known problem that should be further observed by this investigation. Methods: We compared the artifacts of Cochlear 512 magnets at different head positions in vivo at 3 T. The observed positions varied with a nasion-external ear canal angle of 90, 120, and 160 degrees and a variable distance of 5, 7, and 9 cm in relation to the external ear canal and different MRI sequences. Results: The complete assessment of the internal auditory canal and labyrinth was possible with a magnet positioned at 90 degrees and 9 cm and 160 degrees and 9 cm. Evaluation of the IAC alone was possible with magnet positions at 90 degrees and 7 cm and 9 cm, 120 degrees and 9 cm, and 160 degrees and 7 cm and 9 cm. A high-resolution 3D T2w Drive sequence decreased the visibility of the structures significantly. A high-resolution TSE 2D T2w sequence together with one of the above-described positions allowed sufficient visualization of the structures. Conclusion: The position of theAbstract : Hypothesis: To evaluate the assessment of the internal auditory canal and the labyrinth in relation to different CI magnet positions and MRI sequences at 3 T. Background: The indication criteria for cochlear implantation have been changed over the years and the growing number of implantations in patients after acoustic neuroma resections underline the importance of a postoperative MR imaging to assess the internal auditory canal (IAC) and the labyrinth. The MRI artifact induced by the cochlear implant magnet is a known problem that should be further observed by this investigation. Methods: We compared the artifacts of Cochlear 512 magnets at different head positions in vivo at 3 T. The observed positions varied with a nasion-external ear canal angle of 90, 120, and 160 degrees and a variable distance of 5, 7, and 9 cm in relation to the external ear canal and different MRI sequences. Results: The complete assessment of the internal auditory canal and labyrinth was possible with a magnet positioned at 90 degrees and 9 cm and 160 degrees and 9 cm. Evaluation of the IAC alone was possible with magnet positions at 90 degrees and 7 cm and 9 cm, 120 degrees and 9 cm, and 160 degrees and 7 cm and 9 cm. A high-resolution 3D T2w Drive sequence decreased the visibility of the structures significantly. A high-resolution TSE 2D T2w sequence together with one of the above-described positions allowed sufficient visualization of the structures. Conclusion: The position of the implant and the MRI sequence used determine the assessment of the IAC and the labyrinth at 3 T MRI. A position of the implant magnet at a nasion-external auditory canal angle which is more horizontal and posterior than so far commonly used allows a better visualization of the IAC and the labyrinth at 3 T. … (more)
- Is Part Of:
- Otology & neurotology. Volume 36:Issue 6(2015)
- Journal:
- Otology & neurotology
- Issue:
- Volume 36:Issue 6(2015)
- Issue Display:
- Volume 36, Issue 6 (2015)
- Year:
- 2015
- Volume:
- 36
- Issue:
- 6
- Issue Sort Value:
- 2015-0036-0006-0000
- Page Start:
- Page End:
- Publication Date:
- 2015-07
- Subjects:
- 3 T -- Cochlear implant -- Implant positioning -- MRI
Otology -- Periodicals
Ear -- Diseases -- Periodicals
Skull base -- Surgery -- Periodicals
617.8005 - Journal URLs:
- http://www.otology-neurotology.com ↗
http://journals.lww.com ↗ - DOI:
- 10.1097/MAO.0000000000000720 ↗
- Languages:
- English
- ISSNs:
- 1531-7129
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 6313.528000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 5163.xml