Can the Use of Variable-Angle Volar Locking Plates Compensate for Suboptimal Plate Positioning in Unstable Distal Radius Fractures? A Biomechanical Study. Issue 1 (January 2015)
- Record Type:
- Journal Article
- Title:
- Can the Use of Variable-Angle Volar Locking Plates Compensate for Suboptimal Plate Positioning in Unstable Distal Radius Fractures? A Biomechanical Study. Issue 1 (January 2015)
- Main Title:
- Can the Use of Variable-Angle Volar Locking Plates Compensate for Suboptimal Plate Positioning in Unstable Distal Radius Fractures? A Biomechanical Study
- Authors:
- Hart, Adam
Collins, Melissa
Chhatwal, Dane
Steffen, Thomas
Harvey, Edward J.
Martineau, Paul A. - Abstract:
- Abstract : Objective: To compare the biomechanical stability under load-to-failure conditions of optimally placed fixed-angle volar locking plates versus suboptimally placed variable-angle volar locking plates in unstable, intraarticular distal radius fractures. Methods: A Melone type 1 (AO 23-C3) fracture was created in 25 sawbone radii and plated with either a fixed-angle or variable-angle Synthes plate with identical profile. Four plate positions were tested: distal ulnar (DU, positioned distally to obtain subchondral support and ulnar to hold the lunate facet fragments), distal radial (DR, 3 mm radial to DU), proximal ulnar (PU, 3 mm proximal to DU), and proximal radial (PR, 3 mm proximal and 3 mm radial to DU). The specimens were loaded until failure as defined by a 2-mm displacement of any fracture fragment. The fixed-angle plates were tested in the DU position, whereas the variable-angle plates were tested in all 4 positions. Results: The dorsal lunate fragment was the first to fail in every group followed by the radial styloid and volar lunate fragments, respectively. Load-to-failure, from greatest to least, occurred at the DR (278 ± 56 N), PR (277 ± 68 N), DU fixed-angle (277 ± 68 N), DU variable-angle (236 ± 31 N), and PU (202 ± 75 N) positions, respectively. Rigidity was calculated using the slope of the dorsal lunate force–displacement curve before failure (at loads 100–150 N). Rigidity was greatest at the PU position (126 ± 60 N/mm) followed by PR (125 ± 30Abstract : Objective: To compare the biomechanical stability under load-to-failure conditions of optimally placed fixed-angle volar locking plates versus suboptimally placed variable-angle volar locking plates in unstable, intraarticular distal radius fractures. Methods: A Melone type 1 (AO 23-C3) fracture was created in 25 sawbone radii and plated with either a fixed-angle or variable-angle Synthes plate with identical profile. Four plate positions were tested: distal ulnar (DU, positioned distally to obtain subchondral support and ulnar to hold the lunate facet fragments), distal radial (DR, 3 mm radial to DU), proximal ulnar (PU, 3 mm proximal to DU), and proximal radial (PR, 3 mm proximal and 3 mm radial to DU). The specimens were loaded until failure as defined by a 2-mm displacement of any fracture fragment. The fixed-angle plates were tested in the DU position, whereas the variable-angle plates were tested in all 4 positions. Results: The dorsal lunate fragment was the first to fail in every group followed by the radial styloid and volar lunate fragments, respectively. Load-to-failure, from greatest to least, occurred at the DR (278 ± 56 N), PR (277 ± 68 N), DU fixed-angle (277 ± 68 N), DU variable-angle (236 ± 31 N), and PU (202 ± 75 N) positions, respectively. Rigidity was calculated using the slope of the dorsal lunate force–displacement curve before failure (at loads 100–150 N). Rigidity was greatest at the PU position (126 ± 60 N/mm) followed by PR (125 ± 30 N/mm), DU fixed-angle (125 ± 25 N/mm), DR (122 ± 66 N/mm), and DU variable-angle (101 ± 35) positions, respectively. Univariate analysis of rigidity and load-to-failure was not significantly different between groups. Conclusions: In this experimental model, variable-angle screws provided a leeway of 3 mm in both the sagittal and coronal directions without sacrificing construct strength, which may considerably facilitate fixation of these difficult fractures. … (more)
- Is Part Of:
- Journal of orthopaedic trauma. Volume 29:Issue 1(2015)
- Journal:
- Journal of orthopaedic trauma
- Issue:
- Volume 29:Issue 1(2015)
- Issue Display:
- Volume 29, Issue 1 (2015)
- Year:
- 2015
- Volume:
- 29
- Issue:
- 1
- Issue Sort Value:
- 2015-0029-0001-0000
- Page Start:
- Page End:
- Publication Date:
- 2015-01
- Subjects:
- biomechanical study -- distal radius fracture -- fixed-angle locking -- variable-angle locking -- volar locking plate
Orthopedics -- Periodicals
Wounds and injuries -- Periodicals
Orthopedics -- Periodicals
Wounds and Injuries -- therapy -- Periodicals
Periodicals
617.47044 - Journal URLs:
- http://journals.lww.com/jorthotrauma/pages/default.aspx ↗
http://www.jorthotrauma.com ↗
http://cufts2.lib.sfu.ca/CJDB/BVAS/journal/149202 ↗
http://gateway.ovid.com/ovidweb.cgi?T=JS&MODE=ovid&PAGE=toc&D=ovft&AN=00005131-000000000-00000 ↗
http://journals.lww.com ↗ - DOI:
- 10.1097/BOT.0000000000000146 ↗
- Languages:
- English
- ISSNs:
- 0890-5339
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5027.675000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 5150.xml