The immobilization of antibiotic-loaded polymeric coatings on osteoarticular Ti implants for the prevention of bone infections. (16th October 2017)
- Record Type:
- Journal Article
- Title:
- The immobilization of antibiotic-loaded polymeric coatings on osteoarticular Ti implants for the prevention of bone infections. (16th October 2017)
- Main Title:
- The immobilization of antibiotic-loaded polymeric coatings on osteoarticular Ti implants for the prevention of bone infections
- Authors:
- Li, Dan
Lv, Pengfei
Fan, Linfeng
Huang, Yaoyi
Yang, Fei
Mei, Xifan
Wu, Decheng - Abstract:
- Abstract : Polymeric multilayers covalently fixed to Ti surfaces could offer a sustained drug release with no initial burst release and extend the drug release time. Abstract : Implant-associated infections in orthopaedic surgeries are very critical as they may hinder bone healing, cause implant failure and even progress to osteomyelitis. Drug-eluting implants for local delivery of antibiotics at surgical sites are thought to be promising in preventing infections. Herein, the antibiotic vancomycin was encapsulated in a poly(ethylene glycol) (PEG)-based hydrogel film that was covalently bound to Ti implants and subsequently covered by a PEG-poly(lactic- co -caprolactone) (PEG-PLC) membrane. Additionally, crosslinked starch (CSt) was mixed with the hydrogel because its porous microstructure is able to inhibit hydrogel swelling and thus slow down drug release. The release behavior could be regulated by the drug loading and the coating thickness. The vancomycin-loaded Ti implants showed no initial burst release, offering a sustained drug release for nearly 3 weeks in vitro and more than 4 weeks in vivo . In a rabbit model of S. aureus infection, the implants with a 4 mg vancomycin loading significantly reduced the inflammatory reaction and exhibited a good antimicrobial capability. The immobilization of the antibiotic-loaded polymeric coatings on orthopaedic implants can offer a sustainable drug release with no initial burst release and maintain an effective concentration for aAbstract : Polymeric multilayers covalently fixed to Ti surfaces could offer a sustained drug release with no initial burst release and extend the drug release time. Abstract : Implant-associated infections in orthopaedic surgeries are very critical as they may hinder bone healing, cause implant failure and even progress to osteomyelitis. Drug-eluting implants for local delivery of antibiotics at surgical sites are thought to be promising in preventing infections. Herein, the antibiotic vancomycin was encapsulated in a poly(ethylene glycol) (PEG)-based hydrogel film that was covalently bound to Ti implants and subsequently covered by a PEG-poly(lactic- co -caprolactone) (PEG-PLC) membrane. Additionally, crosslinked starch (CSt) was mixed with the hydrogel because its porous microstructure is able to inhibit hydrogel swelling and thus slow down drug release. The release behavior could be regulated by the drug loading and the coating thickness. The vancomycin-loaded Ti implants showed no initial burst release, offering a sustained drug release for nearly 3 weeks in vitro and more than 4 weeks in vivo . In a rabbit model of S. aureus infection, the implants with a 4 mg vancomycin loading significantly reduced the inflammatory reaction and exhibited a good antimicrobial capability. The immobilization of the antibiotic-loaded polymeric coatings on orthopaedic implants can offer a sustainable drug release with no initial burst release and maintain an effective concentration for a longer time, so it is expected to be an effective strategy to treat and prevent local bone infections. … (more)
- Is Part Of:
- Biomaterials science. Volume 5:Number 11(2017:Nov.)
- Journal:
- Biomaterials science
- Issue:
- Volume 5:Number 11(2017:Nov.)
- Issue Display:
- Volume 5, Issue 11 (2017)
- Year:
- 2017
- Volume:
- 5
- Issue:
- 11
- Issue Sort Value:
- 2017-0005-0011-0000
- Page Start:
- 2337
- Page End:
- 2346
- Publication Date:
- 2017-10-16
- Subjects:
- Biomedical materials -- Periodicals
610.28 - Journal URLs:
- http://pubs.rsc.org/en/journals/journalissues/bm ↗
http://www.rsc.org/ ↗ - DOI:
- 10.1039/c7bm00693d ↗
- Languages:
- English
- ISSNs:
- 2047-4830
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 2087.724000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 5156.xml