Automated Analysis of Clozapine and Norclozapine in Human Plasma Using Novel Extraction Plate Technology and Flow-Injection Tandem Mass Spectrometry. Issue 1 (February 2016)
- Record Type:
- Journal Article
- Title:
- Automated Analysis of Clozapine and Norclozapine in Human Plasma Using Novel Extraction Plate Technology and Flow-Injection Tandem Mass Spectrometry. Issue 1 (February 2016)
- Main Title:
- Automated Analysis of Clozapine and Norclozapine in Human Plasma Using Novel Extraction Plate Technology and Flow-Injection Tandem Mass Spectrometry
- Authors:
- Couchman, Lewis
Subramaniam, Krithika
Fisher, Danielle S.
Belsey, Sarah L.
Handley, Simon A.
Flanagan, Robert J. - Abstract:
- Abstract : Background: Analysis of plasma clozapine and N -desmethylclozapine (norclozapine) for therapeutic drug monitoring purposes is well established. To minimize analysis times and facilitate rapid reporting of results, we have fully automated sample preparation using novel AC Extraction Plates and a Tecan Freedom EVO 100 liquid handling platform, and minimized extract analysis times using flow-injection tandem mass spectrometry (FIA-MS/MS). Methods: Analytes and deuterium-labeled internal standards were extracted from plasma (100 μL) at pH 10.6 and extracts analyzed directly using tandem mass spectrometry [20 μL injection, 0.7 mL/min methanol carrier flow, analysis time (injection-to-injection) approximately 60 seconds]. Results: Validation data showed excellent intraplate and interplate accuracy (95%–104% nominal concentrations). Interbatch precision (% RSD) at the limit of quantitation (0.01 mg/L) was 3.5% and 5.5% for clozapine and norclozapine, respectively. Matrix effects were observed for both clozapine and norclozapine, but were compensated for by the internal standards. Overall process efficiency was 56%–70% and 66%–77% for clozapine and norclozapine, respectively. Mean relative process efficiency was 98% and 99% for clozapine and norclozapine, respectively. Comparison of results from patient samples (n = 81) analyzed using (1) manual liquid–liquid extraction with liquid chromatography-tandem mass spectrometry (LC-MS/MS) and (2) automated extraction withAbstract : Background: Analysis of plasma clozapine and N -desmethylclozapine (norclozapine) for therapeutic drug monitoring purposes is well established. To minimize analysis times and facilitate rapid reporting of results, we have fully automated sample preparation using novel AC Extraction Plates and a Tecan Freedom EVO 100 liquid handling platform, and minimized extract analysis times using flow-injection tandem mass spectrometry (FIA-MS/MS). Methods: Analytes and deuterium-labeled internal standards were extracted from plasma (100 μL) at pH 10.6 and extracts analyzed directly using tandem mass spectrometry [20 μL injection, 0.7 mL/min methanol carrier flow, analysis time (injection-to-injection) approximately 60 seconds]. Results: Validation data showed excellent intraplate and interplate accuracy (95%–104% nominal concentrations). Interbatch precision (% RSD) at the limit of quantitation (0.01 mg/L) was 3.5% and 5.5% for clozapine and norclozapine, respectively. Matrix effects were observed for both clozapine and norclozapine, but were compensated for by the internal standards. Overall process efficiency was 56%–70% and 66%–77% for clozapine and norclozapine, respectively. Mean relative process efficiency was 98% and 99% for clozapine and norclozapine, respectively. Comparison of results from patient samples (n = 81) analyzed using (1) manual liquid–liquid extraction with liquid chromatography-tandem mass spectrometry (LC-MS/MS) and (2) automated extraction with FIA-MS/MS gave y = 1.01x − 0.002, R 2 = 0.9943 and y = 1.01x + 0.009, R 2 = 0.9957 for clozapine and norclozapine, respectively. Bland–Altman plots revealed a [mean (95% limits of agreement) bias of 0.0074 (−0.04 to 0.06) mg/L and of 0.015 (−0.02 to 0.05) mg/L for clozapine and norclozapine, respectively]. Conclusions: FIA-MS/MS used with automated extraction offers a rapid, simple, cost-effective alternative to manual liquid–liquid extraction and conventional LC analysis for clozapine therapeutic drug monitoring. Abstract : Supplemental Digital Content is Available in the Text. … (more)
- Is Part Of:
- Therapeutic drug monitoring. Volume 38:Issue 1(2016:Feb.)
- Journal:
- Therapeutic drug monitoring
- Issue:
- Volume 38:Issue 1(2016:Feb.)
- Issue Display:
- Volume 38, Issue 1 (2016)
- Year:
- 2016
- Volume:
- 38
- Issue:
- 1
- Issue Sort Value:
- 2016-0038-0001-0000
- Page Start:
- Page End:
- Publication Date:
- 2016-02
- Subjects:
- clozapine -- norclozapine -- automated extraction -- AC Extraction Plate -- flow-injection analysis
Pharmacokinetics -- Periodicals
Patient monitoring -- Periodicals
Drugs -- Analysis -- Periodicals
Body fluids -- Analysis -- Periodicals
Drug Therapy -- Periodicals
Monitoring, Physiologic -- Periodicals
Pharmacology -- Periodicals
615.7 - Journal URLs:
- http://journals.lww.com/drug-monitoring/pages/default.aspx ↗
http://ovidsp.ovid.com/ovidweb.cgi?T=JS&NEWS=n&CSC=Y&PAGE=toc&D=yrovft&AN=00007691-000000000-00000 ↗
http://www.drug-monitoring.com/ ↗
http://journals.lww.com ↗
http://www.lww.com/Product/0163-4356 ↗ - DOI:
- 10.1097/FTD.0000000000000231 ↗
- Languages:
- English
- ISSNs:
- 0163-4356
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 8814.643000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 5108.xml