Direct Comparison of 4 Very Early Rule-Out Strategies for Acute Myocardial Infarction Using High-Sensitivity Cardiac Troponin I. Issue 17 (25th April 2017)
- Record Type:
- Journal Article
- Title:
- Direct Comparison of 4 Very Early Rule-Out Strategies for Acute Myocardial Infarction Using High-Sensitivity Cardiac Troponin I. Issue 17 (25th April 2017)
- Main Title:
- Direct Comparison of 4 Very Early Rule-Out Strategies for Acute Myocardial Infarction Using High-Sensitivity Cardiac Troponin I
- Authors:
- Boeddinghaus, Jasper
Nestelberger, Thomas
Twerenbold, Raphael
Wildi, Karin
Badertscher, Patrick
Cupa, Janosch
Bürge, Tobias
Mächler, Patrick
Corbière, Sydney
Grimm, Karin
Giménez, Maria Rubini
Puelacher, Christian
Shrestha, Samyut
Flores Widmer, Dayana
Fuhrmann, Jakob
Hillinger, Petra
Sabti, Zaid
Honegger, Ursina
Schaerli, Nicolas
Kozhuharov, Nikola
Rentsch, Katharina
Miró, Òscar
López, Beatriz
Martin-Sanchez, F. Javier
Rodriguez-Adrada, Esther
Morawiec, Beata
Kawecki, Damian
Ganovská, Eva
Parenica, Jiri
Lohrmann, Jens
Kloos, Wanda
Buser, Andreas
Geigy, Nicolas
Keller, Dagmar I.
Osswald, Stefan
Reichlin, Tobias
Mueller, Christian
… (more) - Abstract:
- Abstract : Background: Four strategies for very early rule-out of acute myocardial infarction using high-sensitivity cardiac troponin I (hs-cTnI) have been identified. It remains unclear which strategy is most attractive for clinical application. Methods: We prospectively enrolled unselected patients presenting to the emergency department with symptoms suggestive of acute myocardial infarction. The final diagnosis was adjudicated by 2 independent cardiologists. Hs-cTnI levels were measured at presentation and after 1 hour in a blinded fashion. We directly compared all 4 hs-cTnI–based rule-out strategies: limit of detection (LOD, hs-cTnI<2 ng/L), single cutoff (hs-cTnI<5 ng/L), 1-hour algorithm (hs-cTnI<5 ng/L and 1-hour change<2 ng/L), and the 0/1-hour algorithm recommended in the European Society of Cardiology guideline combining LOD and 1-hour algorithm. Results: Among 2828 enrolled patients, acute myocardial infarction was the final diagnosis in 451 (16%) patients. The LOD approach ruled out 453 patients (16%) with a sensitivity of 100% (95% confidence interval [CI], 99.2%–100%), the single cutoff 1516 patients (54%) with a sensitivity of 97.1% (95% CI, 95.1%–98.3%), the 1-hour algorithm 1459 patients (52%) with a sensitivity of 98.4% (95% CI, 96.8%–99.2%), and the 0/1-hour algorithm 1463 patients (52%) with a sensitivity of 98.4% (95% CI, 96.8%–99.2%). Predefined subgroup analysis in early presenters (⩽2 hours) revealed significantly lower sensitivity (94.2%, interactionAbstract : Background: Four strategies for very early rule-out of acute myocardial infarction using high-sensitivity cardiac troponin I (hs-cTnI) have been identified. It remains unclear which strategy is most attractive for clinical application. Methods: We prospectively enrolled unselected patients presenting to the emergency department with symptoms suggestive of acute myocardial infarction. The final diagnosis was adjudicated by 2 independent cardiologists. Hs-cTnI levels were measured at presentation and after 1 hour in a blinded fashion. We directly compared all 4 hs-cTnI–based rule-out strategies: limit of detection (LOD, hs-cTnI<2 ng/L), single cutoff (hs-cTnI<5 ng/L), 1-hour algorithm (hs-cTnI<5 ng/L and 1-hour change<2 ng/L), and the 0/1-hour algorithm recommended in the European Society of Cardiology guideline combining LOD and 1-hour algorithm. Results: Among 2828 enrolled patients, acute myocardial infarction was the final diagnosis in 451 (16%) patients. The LOD approach ruled out 453 patients (16%) with a sensitivity of 100% (95% confidence interval [CI], 99.2%–100%), the single cutoff 1516 patients (54%) with a sensitivity of 97.1% (95% CI, 95.1%–98.3%), the 1-hour algorithm 1459 patients (52%) with a sensitivity of 98.4% (95% CI, 96.8%–99.2%), and the 0/1-hour algorithm 1463 patients (52%) with a sensitivity of 98.4% (95% CI, 96.8%–99.2%). Predefined subgroup analysis in early presenters (⩽2 hours) revealed significantly lower sensitivity (94.2%, interaction P =0.03) of the single cutoff, but not the other strategies. Two-year survival was 100% with LOD and 98.1% with the other strategies ( P <0.01 for LOD versus each of the other strategies). Conclusions: All 4 rule-out strategies balance effectiveness and safety equally well. The single cutoff should not be applied in early presenters, whereas the 3 other strategies seem to perform well in this challenging subgroup. Clinical Trial Registration: URL:http://www.clinicaltrials.gov . Unique identifier: NCT00470587. Abstract : Supplemental Digital Content is available in the text. … (more)
- Is Part Of:
- Circulation. Volume 135:Issue 17(2017)
- Journal:
- Circulation
- Issue:
- Volume 135:Issue 17(2017)
- Issue Display:
- Volume 135, Issue 17 (2017)
- Year:
- 2017
- Volume:
- 135
- Issue:
- 17
- Issue Sort Value:
- 2017-0135-0017-0000
- Page Start:
- Page End:
- Publication Date:
- 2017-04-25
- Subjects:
- diagnosis -- myocardial infarction -- rule-out strategies
Blood -- Circulation -- Periodicals
Cardiovascular system -- Periodicals
Cardiology -- Periodicals
Heart -- Diseases -- Periodicals
Blood Circulation
Cardiovascular System
Vascular Diseases
616.1 - Journal URLs:
- http://ovidsp.tx.ovid.com/sp-3.4.2a/ovidweb.cgi?&S=HFFJFPCLPODDKOLGNCALDCMCIACKAA00&Browse=Toc+Children%7cNO%7cS.sh.1384_1326796138_84.1384_1326796138_96.1384_1326796138_97%7c66%7c50 ↗
http://www.circulationaha.org ↗
http://circ.ahajournals.org/ ↗
http://journals.lww.com ↗ - DOI:
- 10.1161/CIRCULATIONAHA.116.025661 ↗
- Languages:
- English
- ISSNs:
- 0009-7322
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3265.200000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 5111.xml