Comparison of the Efficacy and Safety of Early Rule-Out Pathways for Acute Myocardial Infarction. Issue 17 (25th April 2017)
- Record Type:
- Journal Article
- Title:
- Comparison of the Efficacy and Safety of Early Rule-Out Pathways for Acute Myocardial Infarction. Issue 17 (25th April 2017)
- Main Title:
- Comparison of the Efficacy and Safety of Early Rule-Out Pathways for Acute Myocardial Infarction
- Authors:
- Chapman, Andrew R.
Anand, Atul
Boeddinghaus, Jasper
Ferry, Amy V.
Sandeman, Dennis
Adamson, Philip D.
Andrews, Jack
Tan, Stephanie
Cheng, Sheun F.
D'Souza, Michelle
Orme, Kate
Strachan, Fiona E.
Nestelberger, Thomas
Twerenbold, Raphael
Badertscher, Patrick
Reichlin, Tobias
Gray, Alasdair
Shah, Anoop S.V.
Mueller, Christian
Newby, David E.
Mills, Nicholas L. - Abstract:
- Abstract : Background: High-sensitivity cardiac troponin assays enable myocardial infarction to be ruled out earlier, but the optimal approach is uncertain. We compared the European Society of Cardiology rule-out pathway with a pathway that incorporates lower cardiac troponin concentrations to risk stratify patients. Methods: Patients with suspected acute coronary syndrome (n=1218) underwent high-sensitivity cardiac troponin I measurement at presentation and 3 and 6 or 12 hours. We compared the European Society of Cardiology pathway (<99th centile at presentation or at 3 hours if symptoms <6 hours) with a pathway developed in the High-STEACS study (High-Sensitivity Troponin in the Evaluation of Patients With Acute Coronary S yndrome) population (<5 ng/L at presentation or change <3 ng/L and <99th centile at 3 hours). The primary outcome was a comparison of the negative predictive value of both pathways for index type 1 myocardial infarction or type 1 myocardial infarction or cardiac death at 30 days. We evaluated the primary outcome in prespecified subgroups stratified by age, sex, time of symptom onset, and known ischemic heart disease. Results: The primary outcome occurred in 15.7% (191 of 1218) patients. In those less than the 99th centile at presentation, the European Society of Cardiology pathway ruled out myocardial infarction in 28.1% (342 of 1218) and 78.9% (961 of 1218) at presentation and 3 hours, respectively, missing 18 index and two 30-day events (negativeAbstract : Background: High-sensitivity cardiac troponin assays enable myocardial infarction to be ruled out earlier, but the optimal approach is uncertain. We compared the European Society of Cardiology rule-out pathway with a pathway that incorporates lower cardiac troponin concentrations to risk stratify patients. Methods: Patients with suspected acute coronary syndrome (n=1218) underwent high-sensitivity cardiac troponin I measurement at presentation and 3 and 6 or 12 hours. We compared the European Society of Cardiology pathway (<99th centile at presentation or at 3 hours if symptoms <6 hours) with a pathway developed in the High-STEACS study (High-Sensitivity Troponin in the Evaluation of Patients With Acute Coronary S yndrome) population (<5 ng/L at presentation or change <3 ng/L and <99th centile at 3 hours). The primary outcome was a comparison of the negative predictive value of both pathways for index type 1 myocardial infarction or type 1 myocardial infarction or cardiac death at 30 days. We evaluated the primary outcome in prespecified subgroups stratified by age, sex, time of symptom onset, and known ischemic heart disease. Results: The primary outcome occurred in 15.7% (191 of 1218) patients. In those less than the 99th centile at presentation, the European Society of Cardiology pathway ruled out myocardial infarction in 28.1% (342 of 1218) and 78.9% (961 of 1218) at presentation and 3 hours, respectively, missing 18 index and two 30-day events (negative predictive value, 97.9%; 95% confidence interval, 96.9–98.7). The High-STEACS pathway ruled out 40.7% (496 of 1218) and 74.2% (904 of 1218) at presentation and 3 hours, missing 2 index and two 30-day events (negative predictive value, 99.5%; 95% confidence interval, 99.0–99.9; P <0.001 for comparison). The negative predictive value of the High-STEACS pathway was greater than the European Society of Cardiology pathway overall ( P <0.001) and in all subgroups, including those presenting early or known to have ischemic heart disease. Conclusions: Use of the High-STEACS pathway incorporating low high-sensitivity cardiac troponin concentrations rules out myocardial infarction in more patients at presentation and misses 5-fold fewer index myocardial infarctions than guideline-approved pathways based exclusively on the 99th centile. Clinical Trial Registration: URL:http://clinicaltrials.gov . Unique identifier: NCT01852123. Abstract : Supplemental Digital Content is available in the text. … (more)
- Is Part Of:
- Circulation. Volume 135:Issue 17(2017)
- Journal:
- Circulation
- Issue:
- Volume 135:Issue 17(2017)
- Issue Display:
- Volume 135, Issue 17 (2017)
- Year:
- 2017
- Volume:
- 135
- Issue:
- 17
- Issue Sort Value:
- 2017-0135-0017-0000
- Page Start:
- Page End:
- Publication Date:
- 2017-04-25
- Subjects:
- acute coronary syndrome -- biomarkers -- myocardial infarction -- troponin
Blood -- Circulation -- Periodicals
Cardiovascular system -- Periodicals
Cardiology -- Periodicals
Heart -- Diseases -- Periodicals
Blood Circulation
Cardiovascular System
Vascular Diseases
616.1 - Journal URLs:
- http://ovidsp.tx.ovid.com/sp-3.4.2a/ovidweb.cgi?&S=HFFJFPCLPODDKOLGNCALDCMCIACKAA00&Browse=Toc+Children%7cNO%7cS.sh.1384_1326796138_84.1384_1326796138_96.1384_1326796138_97%7c66%7c50 ↗
http://www.circulationaha.org ↗
http://circ.ahajournals.org/ ↗
http://journals.lww.com ↗ - DOI:
- 10.1161/CIRCULATIONAHA.116.025021 ↗
- Languages:
- English
- ISSNs:
- 0009-7322
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3265.200000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 5111.xml