Laboratory Evaluation of Femtosecond Laser Lamellar Cuts in Gamma-Irradiated Corneas. Issue 11 (November 2015)
- Record Type:
- Journal Article
- Title:
- Laboratory Evaluation of Femtosecond Laser Lamellar Cuts in Gamma-Irradiated Corneas. Issue 11 (November 2015)
- Main Title:
- Laboratory Evaluation of Femtosecond Laser Lamellar Cuts in Gamma-Irradiated Corneas
- Authors:
- Zhang, Chenxing
Liu, Liang
Tang, Maolong
Li, Yan
Chamberlain, Winston
Huang, David - Abstract:
- Abstract : Purpose: To evaluate the stromal interface quality after femtosecond laser full lamellar cuts in gamma-irradiated corneas (VisionGraft sterile cornea) and to determine the limits of the cut depth using the VisionGraft as donor corneas for laser-assisted lamellar anterior keratoplasty. Methods: Fourteen VisionGraft corneas underwent full lamellar cuts using the femtosecond laser. The percent cut depth was 17% to 21% (100 μm, n = 2), 31% to 35% (n = 3), 38% to 40% (n = 3), 45% to 48% (n = 3), and 50% (n = 3) of the total stromal thickness (not including the epithelium). The cap and stromal bed surfaces were imaged with a scanning electron microscope. The quality of cut surfaces was graded by 2 masked observers based on two indices: ridge and roughness. Ridge grading indicated macroscopic irregularity. Roughness grading indicated microscopic irregularity. The grading was done on a subjective integer scale of 1 to 5 (1 = best and 5 = worst), which was used in a previous study of cut quality in fresh corneas. Results: The ridge grading ranged from 1.5 for the shallowest cut to 2.2 for the deepest cut and weakly (r = 0.279) but significantly ( P = 0.037) correlated with the percent cut depth. The roughness grading ranged from 2.63 to 2.56 and showed no trend with the percent cut depth (r = 0.006, P = 0.968). Conclusions: Compared with previously published results of fresh corneas, in which ridge grading exceeded 3 for cuts deeper than 31%, cut quality was better for theAbstract : Purpose: To evaluate the stromal interface quality after femtosecond laser full lamellar cuts in gamma-irradiated corneas (VisionGraft sterile cornea) and to determine the limits of the cut depth using the VisionGraft as donor corneas for laser-assisted lamellar anterior keratoplasty. Methods: Fourteen VisionGraft corneas underwent full lamellar cuts using the femtosecond laser. The percent cut depth was 17% to 21% (100 μm, n = 2), 31% to 35% (n = 3), 38% to 40% (n = 3), 45% to 48% (n = 3), and 50% (n = 3) of the total stromal thickness (not including the epithelium). The cap and stromal bed surfaces were imaged with a scanning electron microscope. The quality of cut surfaces was graded by 2 masked observers based on two indices: ridge and roughness. Ridge grading indicated macroscopic irregularity. Roughness grading indicated microscopic irregularity. The grading was done on a subjective integer scale of 1 to 5 (1 = best and 5 = worst), which was used in a previous study of cut quality in fresh corneas. Results: The ridge grading ranged from 1.5 for the shallowest cut to 2.2 for the deepest cut and weakly (r = 0.279) but significantly ( P = 0.037) correlated with the percent cut depth. The roughness grading ranged from 2.63 to 2.56 and showed no trend with the percent cut depth (r = 0.006, P = 0.968). Conclusions: Compared with previously published results of fresh corneas, in which ridge grading exceeded 3 for cuts deeper than 31%, cut quality was better for the VisionGraft. Even at depths up to 48% of the total stromal thickness, ridge grading was not worse than shallow cuts. Thus, gamma-irradiated corneas could provide a smoother interface than do fresh eye bank corneas for laser-assisted lamellar anterior keratoplasty. … (more)
- Is Part Of:
- Cornea. Volume 34:Issue 11(2015)
- Journal:
- Cornea
- Issue:
- Volume 34:Issue 11(2015)
- Issue Display:
- Volume 34, Issue 11 (2015)
- Year:
- 2015
- Volume:
- 34
- Issue:
- 11
- Issue Sort Value:
- 2015-0034-0011-0000
- Page Start:
- Page End:
- Publication Date:
- 2015-11
- Subjects:
- femtosecond laser -- scanning electron microscope -- VisionGraft -- anterior lamellar keratoplasty
Cornea -- Periodicals
Cornea -- Periodicals
Cornée -- Périodiques
617.719 - Journal URLs:
- http://journals.lww.com/corneajrnl/pages/default.aspx ↗
http://journals.lww.com ↗ - DOI:
- 10.1097/ICO.0000000000000614 ↗
- Languages:
- English
- ISSNs:
- 0277-3740
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3470.927500
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 5097.xml