Magnetic Resonance Imaging of the Temporomandibular Joint at 7.0 T Using High-Permittivity Dielectric Pads: A Feasibility Study. Issue 12 (December 2015)
- Record Type:
- Journal Article
- Title:
- Magnetic Resonance Imaging of the Temporomandibular Joint at 7.0 T Using High-Permittivity Dielectric Pads: A Feasibility Study. Issue 12 (December 2015)
- Main Title:
- Magnetic Resonance Imaging of the Temporomandibular Joint at 7.0 T Using High-Permittivity Dielectric Pads
- Authors:
- Manoliu, Andrei
Spinner, Georg
Wyss, Michael
Ettlin, Dominik A.
Nanz, Daniel
Kuhn, Felix P.
Gallo, Luigi M.
Andreisek, Gustav - Abstract:
- Abstract : Objectives: The aims of this study were to show feasibility and to quantitatively and qualitatively evaluate the use of high-permittivity dielectric pads for imaging the temporomandibular joint (TMJ) at 7.0 T. Materials and Methods: This study is an institutional review board–approved study with written informed consent. Ten asymptomatic volunteers (20 TMJs) were magnetic resonance imaged using a 32-channel head coil at 7.0 T (Achieva; Philips Healthcare, the Netherlands) with and without high-permittivity dielectric pads consisting of barium titanate in deuterated suspension. Imaging protocol consisted of an oblique sagittal proton density-weighted turbo-spin echo sequence. For quantitative evaluation, B1 maps and voxelwise signal-to-noise ratio (SNR) maps were calculated. For qualitative evaluation, 2 readers assessed the visibility of anatomical structures of the TMJ and overall image quality on a 5-point Likert scale from 1 (excellent visibility) to 5 (not visible) in consensus. Quantitative and qualitative measurements were compared between images acquired with and without pads. Results: Imaging the TMJ using dielectric pads was feasible in all volunteers. The quantitative analysis showed locally higher B1+ and higher SNR in the area covering the TMJ for the scans performed with dielectric pads compared with those without pads (SNR: mean [SD] pads, 12.38 [3.18]; mean [SD] no pads, 6.60 [0.72]). The qualitative analysis showed significantly better visibilityAbstract : Objectives: The aims of this study were to show feasibility and to quantitatively and qualitatively evaluate the use of high-permittivity dielectric pads for imaging the temporomandibular joint (TMJ) at 7.0 T. Materials and Methods: This study is an institutional review board–approved study with written informed consent. Ten asymptomatic volunteers (20 TMJs) were magnetic resonance imaged using a 32-channel head coil at 7.0 T (Achieva; Philips Healthcare, the Netherlands) with and without high-permittivity dielectric pads consisting of barium titanate in deuterated suspension. Imaging protocol consisted of an oblique sagittal proton density-weighted turbo-spin echo sequence. For quantitative evaluation, B1 maps and voxelwise signal-to-noise ratio (SNR) maps were calculated. For qualitative evaluation, 2 readers assessed the visibility of anatomical structures of the TMJ and overall image quality on a 5-point Likert scale from 1 (excellent visibility) to 5 (not visible) in consensus. Quantitative and qualitative measurements were compared between images acquired with and without pads. Results: Imaging the TMJ using dielectric pads was feasible in all volunteers. The quantitative analysis showed locally higher B1+ and higher SNR in the area covering the TMJ for the scans performed with dielectric pads compared with those without pads (SNR: mean [SD] pads, 12.38 [3.18]; mean [SD] no pads, 6.60 [0.72]). The qualitative analysis showed significantly better visibility and delineation of clinically relevant anatomical structures of the TMJ, including temporomandibular disc, bilaminar zone, mandibular fossa, mandibular condyle, and pterygoid muscle. In addition, observers judged overall image quality as better for images taken with pads compared with those taken without pads (mean [SD] pads, 1.40 [0.50]; mean [SD] no pads, 4.25 [0.78]). Conclusions: The application of high-permittivity dielectric pads improves the local B1+ field and thus the SNR, optimizing TMJ magnetic resonance imaging at 7.0 T. … (more)
- Is Part Of:
- Investigative radiology. Volume 50:Issue 12(2015:Dec.)
- Journal:
- Investigative radiology
- Issue:
- Volume 50:Issue 12(2015:Dec.)
- Issue Display:
- Volume 50, Issue 12 (2015)
- Year:
- 2015
- Volume:
- 50
- Issue:
- 12
- Issue Sort Value:
- 2015-0050-0012-0000
- Page Start:
- Page End:
- Publication Date:
- 2015-12
- Subjects:
- temporomandibular joint -- ultrahigh magnetic field strengths -- high-permittivity dielectric pads
Diagnosis, Radioscopic -- Periodicals
Radiology, Medical -- Periodicals
616.0757 - Journal URLs:
- http://journals.lww.com/investigativeradiology/pages/default.aspx ↗
http://journals.lww.com ↗ - DOI:
- 10.1097/RLI.0000000000000196 ↗
- Languages:
- English
- ISSNs:
- 0020-9996
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4560.350000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 5086.xml