High-Pitch Low-Dose Whole-Body Computed Tomography for the Assessment of Ventriculoperitoneal Shunts in a Pediatric Patient Model: An Experimental Ex Vivo Study in Rabbits. Issue 12 (December 2015)
- Record Type:
- Journal Article
- Title:
- High-Pitch Low-Dose Whole-Body Computed Tomography for the Assessment of Ventriculoperitoneal Shunts in a Pediatric Patient Model: An Experimental Ex Vivo Study in Rabbits. Issue 12 (December 2015)
- Main Title:
- High-Pitch Low-Dose Whole-Body Computed Tomography for the Assessment of Ventriculoperitoneal Shunts in a Pediatric Patient Model
- Authors:
- Othman, Ahmed E.
Afat, Saif
Hamou, Hussam A.
Pjontek, Rastislav
Tsiflikas, Ilias
Nikoubashman, Omid
Brockmann, Marc A.
Nikolaou, Konstantin
Clusmann, Hans
Wiesmann, Martin - Abstract:
- Abstract : Objective: The aim of this study was to assess the diagnostic value of whole-body low-dose (LD) computed tomography (CT) for the detection of ventriculoperitoneal (VP) shunt complications in pediatric patients compared with radiographic shunt series (SS) in an ex vivo rabbit animal model. Methods: In the first step, 2 optimized LD-CT imaging protocols, with high pitch (pitch, 3.2), low tube voltages (70 kVp and 80 kVp), and using both filtered back projection and iterative reconstruction, were assessed on a 16-cm solid polymethylmethacrylate phantom regarding signal-to-noise ratio and radiation dose. Taking both radiation dose and signal-to-noise ratio into account, the LD-CT protocol (80 kVp; 4 mA; pitch, 3.2) was identified as most appropriate and therefore applied in this study. After identification of appropriate LD-CT protocol, 12 VP shunts were implanted in 6 rabbit cadavers (mean weight, 5.1 kg). Twenty-four mechanical complications (extracranial and extraperitoneal malpositioning, breakages, and disconnections) were induced in half of the VP shunts. Low-dose CT and conventional SS were acquired in standard fashion. Dose-area products (DAPs) for SS and LD-CT were collected; effective radiation doses for both SS and LD-CT were estimated using CT-Expo (v. 2.3.1.) and age-specific effective dose (ED) estimates. Qualitative scoring of diagnostic confidence on a 5-point Likert scale (1, very low diagnostic confidence; 5, excellent diagnostic confidence) andAbstract : Objective: The aim of this study was to assess the diagnostic value of whole-body low-dose (LD) computed tomography (CT) for the detection of ventriculoperitoneal (VP) shunt complications in pediatric patients compared with radiographic shunt series (SS) in an ex vivo rabbit animal model. Methods: In the first step, 2 optimized LD-CT imaging protocols, with high pitch (pitch, 3.2), low tube voltages (70 kVp and 80 kVp), and using both filtered back projection and iterative reconstruction, were assessed on a 16-cm solid polymethylmethacrylate phantom regarding signal-to-noise ratio and radiation dose. Taking both radiation dose and signal-to-noise ratio into account, the LD-CT protocol (80 kVp; 4 mA; pitch, 3.2) was identified as most appropriate and therefore applied in this study. After identification of appropriate LD-CT protocol, 12 VP shunts were implanted in 6 rabbit cadavers (mean weight, 5.1 kg). Twenty-four mechanical complications (extracranial and extraperitoneal malpositioning, breakages, and disconnections) were induced in half of the VP shunts. Low-dose CT and conventional SS were acquired in standard fashion. Dose-area products (DAPs) for SS and LD-CT were collected; effective radiation doses for both SS and LD-CT were estimated using CT-Expo (v. 2.3.1.) and age-specific effective dose (ED) estimates. Qualitative scoring of diagnostic confidence on a 5-point Likert scale (1, very low diagnostic confidence; 5, excellent diagnostic confidence) and blinded readings of both SS and LD-CTs were performed. Results: Among the 24 VP shunt complications, LD-CT yielded excellent sensitivity and specificity for the detection of VP shunt complications (sensitivity, 0.98; specificity, 1; 95% confidence interval, 0.92-1) with excellent interobserver agreement (κ = 0.90). Shunt series yielded good sensitivity and specificity (sensitivity, 0.75; specificity, 1; 95% confidence interval, 0.58–0.92) with moderate interobserver agreement (κ = 0.56). No false-positive findings were registered. Compared with SS, LD-CT yielded significantly lower ED and DAPs (ED, 0.039 vs 0.062 mSv; DAP, 20.5 vs 26.3; P < 0.05). Conclusions: In this experimental ex vivo pediatric patient model, LD-CT yields excellent sensitivity for the detection of VP shunt complications at higher diagnostic confidence and lower radiation exposure compared with SS. … (more)
- Is Part Of:
- Investigative radiology. Volume 50:Issue 12(2015:Dec.)
- Journal:
- Investigative radiology
- Issue:
- Volume 50:Issue 12(2015:Dec.)
- Issue Display:
- Volume 50, Issue 12 (2015)
- Year:
- 2015
- Volume:
- 50
- Issue:
- 12
- Issue Sort Value:
- 2015-0050-0012-0000
- Page Start:
- Page End:
- Publication Date:
- 2015-12
- Subjects:
- ventriculoperitoneal shunt -- computed tomography -- LD-CT -- radiation dose
Diagnosis, Radioscopic -- Periodicals
Radiology, Medical -- Periodicals
616.0757 - Journal URLs:
- http://journals.lww.com/investigativeradiology/pages/default.aspx ↗
http://journals.lww.com ↗ - DOI:
- 10.1097/RLI.0000000000000195 ↗
- Languages:
- English
- ISSNs:
- 0020-9996
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4560.350000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 5086.xml