Agreement between Automated and Traditional Measures of Tear Film Breakup. Issue 9 (September 2015)
- Record Type:
- Journal Article
- Title:
- Agreement between Automated and Traditional Measures of Tear Film Breakup. Issue 9 (September 2015)
- Main Title:
- Agreement between Automated and Traditional Measures of Tear Film Breakup
- Authors:
- Cox, Stephanie M.
Nichols, Kelly K.
Nichols, Jason J. - Abstract:
- ABSTRACT: Purpose: To determine the repeatability and agreement between the noninvasive Keratograph tear break-up time (NIK-BUT) as measured by the Oculus Keratograph 4 and fluorescein tear break-up time (FBUT). Methods: Sixty subjects were recruited for two study visits separated by 7 (±2) days. At each visit, three NIK-BUT measures and FBUT measures were obtained. Each NIK-BUT measure from the Keratograph included a first and an average NIK-BUT. The means of the measures obtained, first NIK-BUT, and average NIK-BUT and FBUT were calculated for each visit. Between- and within-visit agreement was assessed using intraclass correlation coefficients (ICCs) and Bland-Altman 95% limits of agreement (LoA) analyses of log-transformed data. Results: Between-visit ICCs were 0.53 [95% confidence interval (CI), 0.32 to 0.69] for first NIK-BUT, 0.59 (95% CI, 0.40 to 0.73) for average NIK-BUT, and 0.66 (95% CI, 0.49 to 0.78) for FBUT, whereas 95% LoA were −0.65 to 0.67, −0.44 to 0.48, and −1.14 to 1.10 [back transformed: (visit 1 + 0.01)/(visit 2 + 0.01) = 0.22 to 4.68, 0.36 to 3.02, and 0.07 to 12.59] for the aforementioned methods, respectively. The visit 1 within-visit ICC between first NIK-BUT and FBUT was 0.44 (95% CI, 0.21 to 0.62), whereas the 95% LoA was −0.84 to 1.18 [back transformed: (first NIK-BUT + 0.01)/(FBUT + 0.01) = 0.14 to 15.14]. Likewise, the visit 1 within-visit ICC between average NIK-BUT and FBUT was 0.41 (95% CI, 0.18 to 0.60), whereas the 95% LoA was −0.58 toABSTRACT: Purpose: To determine the repeatability and agreement between the noninvasive Keratograph tear break-up time (NIK-BUT) as measured by the Oculus Keratograph 4 and fluorescein tear break-up time (FBUT). Methods: Sixty subjects were recruited for two study visits separated by 7 (±2) days. At each visit, three NIK-BUT measures and FBUT measures were obtained. Each NIK-BUT measure from the Keratograph included a first and an average NIK-BUT. The means of the measures obtained, first NIK-BUT, and average NIK-BUT and FBUT were calculated for each visit. Between- and within-visit agreement was assessed using intraclass correlation coefficients (ICCs) and Bland-Altman 95% limits of agreement (LoA) analyses of log-transformed data. Results: Between-visit ICCs were 0.53 [95% confidence interval (CI), 0.32 to 0.69] for first NIK-BUT, 0.59 (95% CI, 0.40 to 0.73) for average NIK-BUT, and 0.66 (95% CI, 0.49 to 0.78) for FBUT, whereas 95% LoA were −0.65 to 0.67, −0.44 to 0.48, and −1.14 to 1.10 [back transformed: (visit 1 + 0.01)/(visit 2 + 0.01) = 0.22 to 4.68, 0.36 to 3.02, and 0.07 to 12.59] for the aforementioned methods, respectively. The visit 1 within-visit ICC between first NIK-BUT and FBUT was 0.44 (95% CI, 0.21 to 0.62), whereas the 95% LoA was −0.84 to 1.18 [back transformed: (first NIK-BUT + 0.01)/(FBUT + 0.01) = 0.14 to 15.14]. Likewise, the visit 1 within-visit ICC between average NIK-BUT and FBUT was 0.41 (95% CI, 0.18 to 0.60), whereas the 95% LoA was −0.58 to 1.44 [back transformed: (average NIK-BUT + 0.01)/(FBUT + 0.01) = 0.26 to 27.54]. Conclusions: The 95% LoA suggest that the average NIK-BUT has better between-visit agreement compared with the first NIK-BUT or FBUT. The first NIK-BUT showed better within-visit agreement with the FBUT than the average NIK-BUT. In addition, there is better between- and within-visit agreement for all measures at lower values. … (more)
- Is Part Of:
- Optometry and vision science. Volume 92:Issue 9(2015)
- Journal:
- Optometry and vision science
- Issue:
- Volume 92:Issue 9(2015)
- Issue Display:
- Volume 92, Issue 9 (2015)
- Year:
- 2015
- Volume:
- 92
- Issue:
- 9
- Issue Sort Value:
- 2015-0092-0009-0000
- Page Start:
- Page End:
- Publication Date:
- 2015-09
- Subjects:
- noninvasive tear break-up time -- fluorescein tear break-up time -- repeatability -- tear film
Optometry -- Periodicals
Physiological optics -- Periodicals
Vision disorders -- Periodicals
617.7505 - Journal URLs:
- http://gateway.ovid.com/ovidweb.cgi?T=JS&MODE=ovid&PAGE=toc&D=ovft&AN=00006324-000000000-00000 ↗
http://www.optvissci.com ↗
http://journals.lww.com ↗ - DOI:
- 10.1097/OPX.0000000000000648 ↗
- Languages:
- English
- ISSNs:
- 1040-5488
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 6276.450000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 5085.xml