Feasibility and reliability of carotid intima–media thickness measurements in nonsedated infants. Issue 11 (November 2016)
- Record Type:
- Journal Article
- Title:
- Feasibility and reliability of carotid intima–media thickness measurements in nonsedated infants. Issue 11 (November 2016)
- Main Title:
- Feasibility and reliability of carotid intima–media thickness measurements in nonsedated infants
- Authors:
- Mivelaz, Yvan
Di Bernardo, Stefano
Boulos Ksontini, Tatiana
Prsa, Milan
Vial, Yvan
Chiolero, Arnaud
Sekarski, Nicole - Abstract:
- Abstract : Introduction: Carotid intima–media thickness (CIMT) is a surrogate marker for atherosclerosis. It is increased in adolescents and young adults at risk for future cardiovascular disease. However, it remains unclear if it can be considered as a surrogate marker for atherosclerosis in infancy as very few studies have been performed in infants. Objectives: Our objective was to assess the feasibility and interobserver reproducibility of CIMT measurement in nonsedated infants. Methods: We measured CIMT in 81 infants less than 1 year of age. Repeated measurements were obtained by a second observer in 24 children. The analysis was performed with semiautomated edge detection software. Measurements with over 95% edge detection over a length of 1 cm were considered as valid. We further compared the measurements using the semiautomated method with measurements using the manual electronic caliper method in a subgroup of 10 infants. Results: Carotid ultrasound recordings and intima–media thickness measurements were obtained in 79% of infants ( n = 64). Mean CIMT of the 64 infants measured by the first observer was 0.44 mm (SD: 0.04). In the 24 participants with measurements by two observers, the mean interobserver difference was 0.001 mm (SD: 0.026). The interobserver coefficient of variation was 5.9%. CIMT measurements obtained with the manual method (mean: 0.35; range: 0.29–0.39) were slightly lower than measurements obtained with the semiautomated method (mean: 0.38; range:Abstract : Introduction: Carotid intima–media thickness (CIMT) is a surrogate marker for atherosclerosis. It is increased in adolescents and young adults at risk for future cardiovascular disease. However, it remains unclear if it can be considered as a surrogate marker for atherosclerosis in infancy as very few studies have been performed in infants. Objectives: Our objective was to assess the feasibility and interobserver reproducibility of CIMT measurement in nonsedated infants. Methods: We measured CIMT in 81 infants less than 1 year of age. Repeated measurements were obtained by a second observer in 24 children. The analysis was performed with semiautomated edge detection software. Measurements with over 95% edge detection over a length of 1 cm were considered as valid. We further compared the measurements using the semiautomated method with measurements using the manual electronic caliper method in a subgroup of 10 infants. Results: Carotid ultrasound recordings and intima–media thickness measurements were obtained in 79% of infants ( n = 64). Mean CIMT of the 64 infants measured by the first observer was 0.44 mm (SD: 0.04). In the 24 participants with measurements by two observers, the mean interobserver difference was 0.001 mm (SD: 0.026). The interobserver coefficient of variation was 5.9%. CIMT measurements obtained with the manual method (mean: 0.35; range: 0.29–0.39) were slightly lower than measurements obtained with the semiautomated method (mean: 0.38; range: 0.32–0.44). Measurements with both methods were highly correlated ( r : 0.87). Conclusion: Measurement of CIMT in nonsedated infants less than 1 year of age is feasible in the majority of infants with good interobserver variability. … (more)
- Is Part Of:
- Journal of hypertension. Volume 34:Issue 11(2016:Nov.)
- Journal:
- Journal of hypertension
- Issue:
- Volume 34:Issue 11(2016:Nov.)
- Issue Display:
- Volume 34, Issue 11 (2016)
- Year:
- 2016
- Volume:
- 34
- Issue:
- 11
- Issue Sort Value:
- 2016-0034-0011-0000
- Page Start:
- 2227
- Page End:
- 2232
- Publication Date:
- 2016-11
- Subjects:
- atherosclerosis -- carotid artery intima–media thickness -- feasibility -- infants -- reliability
Hypertension -- Periodicals
Hypertension -- Periodicals
616.132005 - Journal URLs:
- http://firstsearch.oclc.org ↗
http://journals.lww.com/jhypertension/pages/default.aspx ↗
http://ovidsp.ovid.com/ovidweb.cgi?T=JS&NEWS=n&CSC=Y&PAGE=toc&D=yrovft&AN=00004872-000000000-00000 ↗
http://www.jhypertension.com/ ↗
http://journals.lww.com/pages/default.aspx ↗ - DOI:
- 10.1097/HJH.0000000000001065 ↗
- Languages:
- English
- ISSNs:
- 1473-5598
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5004.510000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 5069.xml