Defining Prolonged Dwell Time: When Are Advanced Inferior Vena Cava Filter Retrieval Techniques Necessary?. (June 2017)
- Record Type:
- Journal Article
- Title:
- Defining Prolonged Dwell Time: When Are Advanced Inferior Vena Cava Filter Retrieval Techniques Necessary?. (June 2017)
- Main Title:
- Defining Prolonged Dwell Time
- Authors:
- Desai, Kush R.
Laws, James L.
Salem, Riad
Mouli, Samdeep K.
Errea, Martin F.
Karp, Jennifer K.
Yang, Yihe
Ryu, Robert K.
Lewandowski, Robert J. - Abstract:
- Abstract : Background—: Despite growth in placement of retrievable inferior vena cava filters, retrieval rates remain low. Filters with extended implantation times present a challenge to retrieval, where standard techniques often fail. The development of advanced retrieval techniques has positively impacted retrieval of retrievable inferior vena cava filters with prolonged dwell times; however, there is no precise definition of the time point when advanced techniques become necessary. We aim to define prolonged retrievable inferior vena cava filters dwell time by determining the inflection point when the risk of standard retrieval technique failure increases significantly, necessitating advanced retrieval techniques to maintain overall technical success of retrieval. Methods and Results—: From January 2009 to April 2015, 762 retrieval procedures were identified from a prospectively acquired database. We assessed patient age/sex, filter dwell time, procedural technical success, the use of advanced techniques, and procedure-related adverse events. Overall retrieval success rate was 98% (n=745). When standard retrieval techniques failed, advanced techniques were used; this was necessary 18% of the time (n=138). Logistic regression identified that dwell time was the only risk factor for failure of standard retrieval technique (odds ratio, 1.08; 95% confidence interval, 1.05–1.10; P <0.001). Spline function regression analysis demonstrated that if dwell time exceeded 7 months,Abstract : Background—: Despite growth in placement of retrievable inferior vena cava filters, retrieval rates remain low. Filters with extended implantation times present a challenge to retrieval, where standard techniques often fail. The development of advanced retrieval techniques has positively impacted retrieval of retrievable inferior vena cava filters with prolonged dwell times; however, there is no precise definition of the time point when advanced techniques become necessary. We aim to define prolonged retrievable inferior vena cava filters dwell time by determining the inflection point when the risk of standard retrieval technique failure increases significantly, necessitating advanced retrieval techniques to maintain overall technical success of retrieval. Methods and Results—: From January 2009 to April 2015, 762 retrieval procedures were identified from a prospectively acquired database. We assessed patient age/sex, filter dwell time, procedural technical success, the use of advanced techniques, and procedure-related adverse events. Overall retrieval success rate was 98% (n=745). When standard retrieval techniques failed, advanced techniques were used; this was necessary 18% of the time (n=138). Logistic regression identified that dwell time was the only risk factor for failure of standard retrieval technique (odds ratio, 1.08; 95% confidence interval, 1.05–1.10; P <0.001). Spline function regression analysis demonstrated that if dwell time exceeded 7 months, the risk of standard technique failure was 40.9%. Adverse events occurred at a rate of 2% (n=18; 15 minor and 3 major). Conclusions—: The necessity of advanced techniques to maintain technical success of retrieval increases with dwell time. Patients with retrievable inferior vena cava filters in place beyond 7 months may benefit from referral to centers with expertise in advanced filter retrieval. … (more)
- Is Part Of:
- Circulation. Volume 10:Number 6(2017)
- Journal:
- Circulation
- Issue:
- Volume 10:Number 6(2017)
- Issue Display:
- Volume 10, Issue 6 (2017)
- Year:
- 2017
- Volume:
- 10
- Issue:
- 6
- Issue Sort Value:
- 2017-0010-0006-0000
- Page Start:
- Page End:
- Publication Date:
- 2017-06
- Subjects:
- humans -- pulmonary embolism -- risk factors -- vena cava filters -- venous thrombosis
Cardiovascular system -- Surgery -- Periodicals
Cardiovascular system -- Diseases -- Treatment -- Periodicals
616.105 - Journal URLs:
- http://gateway.ovid.com/ovidweb.cgi?T=JS&MODE=ovid&PAGE=toc&D=ovft&AN=01337495-000000000-00000 ↗
http://circinterventions.ahajournals.org/ ↗
http://journals.lww.com ↗ - DOI:
- 10.1161/CIRCINTERVENTIONS.116.003957 ↗
- Languages:
- English
- ISSNs:
- 1941-7640
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3265.262560
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 5070.xml