Is intra‐procedure three‐dimensional transesophageal echocardiogram an alternative to preprocedure multidetector computed tomography for the measurement of the aortic annulus in patients undergoing transcatheter aortic valve replacement?. Issue 8 (18th July 2017)
- Record Type:
- Journal Article
- Title:
- Is intra‐procedure three‐dimensional transesophageal echocardiogram an alternative to preprocedure multidetector computed tomography for the measurement of the aortic annulus in patients undergoing transcatheter aortic valve replacement?. Issue 8 (18th July 2017)
- Main Title:
- Is intra‐procedure three‐dimensional transesophageal echocardiogram an alternative to preprocedure multidetector computed tomography for the measurement of the aortic annulus in patients undergoing transcatheter aortic valve replacement?
- Authors:
- Hafiz, Abdul Moiz
Medranda, Giorgio A.
Kakouros, Nikolaos
Patel, Jay
Kahan, Jonathan
Gubernikoff, George
Ray, Beevash
Paruchuri, Vijayapraveena
DeLeon, Joshua
Marzo, Kevin
Calixte, Rose
Gaztanaga, Juan - Abstract:
- Abstract : Background: The role of three‐dimensional transesophageal echocardiography (3DTEE) vs multidetector computed tomography (MDCT) in aortic annular sizing has been poorly defined in patients undergoing transcatheter aortic valve replacements (TAVR). We set to determine the correlation between 3DTEE and MDCT in measuring the aortic annulus prior to TAVR. Methods: In an observational, retrospective study, we compared aortic annular areas measured by MDCT and 3DTEE in TAVR patients. The aortic annular area was measured by planimetry of images obtained by MDCT pre‐TAVR and by intra‐TAVR TEE using 3D rendering of the aortic annulus followed by planimetry. Our primary outcome was degree of correlation between mean aortic annulus area by 3DTEE and MDCT. Results: Of the 111 consecutive patients undergoing TAVR who had measurements from both modalities available for comparison between February 2012 and April 2015, 87 met inclusion criteria. The mean aortic annular area by MDCT was 4.44±0.88 cm 2 and by 3DTEE was 4.33±0.78 cm 2 . There was a strong positive linear correlation between aortic annular area measurements obtained from these two modalities with mild relative underestimation by 3DTEE (ρ=.833). This relationship can be estimated using the predictive formula: MDCT Aortic Annular Area = 0.605 + 0.878 × 3 DTEE Aortic Annular Area Conclusions: Three‐dimensional transesophageal echocardiography measurements have a high degree of correlation with MDCT measurements and thusAbstract : Background: The role of three‐dimensional transesophageal echocardiography (3DTEE) vs multidetector computed tomography (MDCT) in aortic annular sizing has been poorly defined in patients undergoing transcatheter aortic valve replacements (TAVR). We set to determine the correlation between 3DTEE and MDCT in measuring the aortic annulus prior to TAVR. Methods: In an observational, retrospective study, we compared aortic annular areas measured by MDCT and 3DTEE in TAVR patients. The aortic annular area was measured by planimetry of images obtained by MDCT pre‐TAVR and by intra‐TAVR TEE using 3D rendering of the aortic annulus followed by planimetry. Our primary outcome was degree of correlation between mean aortic annulus area by 3DTEE and MDCT. Results: Of the 111 consecutive patients undergoing TAVR who had measurements from both modalities available for comparison between February 2012 and April 2015, 87 met inclusion criteria. The mean aortic annular area by MDCT was 4.44±0.88 cm 2 and by 3DTEE was 4.33±0.78 cm 2 . There was a strong positive linear correlation between aortic annular area measurements obtained from these two modalities with mild relative underestimation by 3DTEE (ρ=.833). This relationship can be estimated using the predictive formula: MDCT Aortic Annular Area = 0.605 + 0.878 × 3 DTEE Aortic Annular Area Conclusions: Three‐dimensional transesophageal echocardiography measurements have a high degree of correlation with MDCT measurements and thus can assist in proper valve prosthesis selection for TAVR. Our study thus supports use of 3DTEE as a reasonable alternative imaging modality in patients undergoing TAVR. … (more)
- Is Part Of:
- Echocardiography. Volume 34:Issue 8(2017)
- Journal:
- Echocardiography
- Issue:
- Volume 34:Issue 8(2017)
- Issue Display:
- Volume 34, Issue 8 (2017)
- Year:
- 2017
- Volume:
- 34
- Issue:
- 8
- Issue Sort Value:
- 2017-0034-0008-0000
- Page Start:
- 1195
- Page End:
- 1202
- Publication Date:
- 2017-07-18
- Subjects:
- multidetector computed tomography -- three‐dimensional transesophageal echocardiography -- transcatheter aortic valve replacement
Echocardiography -- Periodicals
Echocardiography -- Periodicals
616.1207543 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1111/(ISSN)1540-8175 ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1111/echo.13613 ↗
- Languages:
- English
- ISSNs:
- 0742-2822
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3647.572500
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File: