Clinical Evaluation of a Prototype Underwear Designed to Detect Urine Leakage From Continence Pads. Issue 6 (November 2015)
- Record Type:
- Journal Article
- Title:
- Clinical Evaluation of a Prototype Underwear Designed to Detect Urine Leakage From Continence Pads. Issue 6 (November 2015)
- Main Title:
- Clinical Evaluation of a Prototype Underwear Designed to Detect Urine Leakage From Continence Pads
- Authors:
- Long, Adele
Edwards, Julia
Worthington, Joanna
Cotterill, Nikki
Weir, Iain
Drake, Marcus J.
van den Heuvel, Eleanor - Abstract:
- Abstract : PURPOSE: We evaluated the performance of prototype underwear designed to detect urine leakage from continence pads, their acceptability to users, and their effect on health-related quality of life and psychosocial factors. DESIGN: Prototype product evaluation. SUBJECTS AND SETTING: Participants were 81 women with an average age of 67 years (range, 32-98 years) recruited between October 2010 and February 2012 from outpatient clinics, general practice surgeries, community continence services, and through charities and networks. METHODS: The TACT3 project developed and manufactured a prototype undergarment designed to alert the wearer to a pad leak before it reaches outer clothing or furniture. The study was conducted in 2 stages: a pilot/feasibility study to assess general performance and a larger study to measure performance, acceptability to users, health-related quality of life, and psychosocial impact. Participants were asked to wear the prototype underwear for a period of 2 weeks, keeping a daily diary of leakage events for the first 7 days. They also completed validated instruments measuring lower urinary tract symptoms, health-related quality of life, and psychosocial impact. RESULTS: On average, 86% of the time participants were alerted to pad leakage events. More than 90% thought the prototype underwear was "good" or "OK" and that it would or could give them more confidence. Mean scores for the International Consultation on IncontinenceAbstract : PURPOSE: We evaluated the performance of prototype underwear designed to detect urine leakage from continence pads, their acceptability to users, and their effect on health-related quality of life and psychosocial factors. DESIGN: Prototype product evaluation. SUBJECTS AND SETTING: Participants were 81 women with an average age of 67 years (range, 32-98 years) recruited between October 2010 and February 2012 from outpatient clinics, general practice surgeries, community continence services, and through charities and networks. METHODS: The TACT3 project developed and manufactured a prototype undergarment designed to alert the wearer to a pad leak before it reaches outer clothing or furniture. The study was conducted in 2 stages: a pilot/feasibility study to assess general performance and a larger study to measure performance, acceptability to users, health-related quality of life, and psychosocial impact. Participants were asked to wear the prototype underwear for a period of 2 weeks, keeping a daily diary of leakage events for the first 7 days. They also completed validated instruments measuring lower urinary tract symptoms, health-related quality of life, and psychosocial impact. RESULTS: On average, 86% of the time participants were alerted to pad leakage events. More than 90% thought the prototype underwear was "good" or "OK" and that it would or could give them more confidence. Mean scores for the International Consultation on Incontinence Questionnaire-Urinary Incontinence Short Form indicated no change in the level of symptoms reported before or after the intervention, and no significant changes in health-related quality of life status occurred, except improvement in for travel restrictions. Evaluation via the Psychosocial Impact of Assistive Devices Scale also indicated a positive impact. CONCLUSION: The prototype underwear evaluated in this study was effective and acceptable for 5 out of every 10 wearers. Findings also suggest that the prototype underwear is suitable for women of all ages, dress sizes, and continence severity. … (more)
- Is Part Of:
- Journal of WOCN. Volume 42:Issue 6(2015)
- Journal:
- Journal of WOCN
- Issue:
- Volume 42:Issue 6(2015)
- Issue Display:
- Volume 42, Issue 6 (2015)
- Year:
- 2015
- Volume:
- 42
- Issue:
- 6
- Issue Sort Value:
- 2015-0042-0006-0000
- Page Start:
- Page End:
- Publication Date:
- 2015-11
- Subjects:
- Absorptive products -- Adults -- Urinary incontinence
Abdomen -- Surgery -- Periodicals
Abdomen -- Wounds and injuries -- Nursing -- Periodicals
Bedsores -- Nursing -- Periodicals
Fecal incontinence -- Nursing -- Periodicals
Enterostomy -- Nursing -- Periodicals
Urinary incontinence -- Nursing -- Periodicals
610.73 - Journal URLs:
- http://journals.lww.com/jwocnonline/pages/default.aspx ↗
http://journals.lww.com ↗ - DOI:
- 10.1097/WON.0000000000000178 ↗
- Languages:
- English
- ISSNs:
- 1071-5754
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5072.632700
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 5071.xml