Exchange of supraglottic airways for endotracheal tube using the Eschmann Introducer during simulated child resuscitation: A randomized study comparing 4 devices. Issue 26 (June 2017)
- Record Type:
- Journal Article
- Title:
- Exchange of supraglottic airways for endotracheal tube using the Eschmann Introducer during simulated child resuscitation: A randomized study comparing 4 devices. Issue 26 (June 2017)
- Main Title:
- Exchange of supraglottic airways for endotracheal tube using the Eschmann Introducer during simulated child resuscitation
- Authors:
- Szarpak, Lukasz
Truszewski, Zenon
Vitale, Joseph
Glosser, Logan
Ruetzler, Kurt
Rodríguez-Núñez, Antonio - Other Names:
- Adesina. Adebowale section editor.
- Abstract:
- Abstract: Background: The aim of this study was to examine the application of the Eschmann tracheal tube introducer (ETTI) with 4 types of supraglottic airway devices (SADs) using a child-manikin. Methods: A total of 79 paramedics were asked to exchange the 4 SADs for an endotracheal tube with the ETTI in 3 different scenarios using a randomized crossover study format: normal airway without chest compression; normal airway with uninterrupted chest compression; and difficult airway with uninterrupted chest compression. The primary outcome was time to SAD exchange, with the secondary outcome measuring the success of SAD exchange. Each attempt was assessed by a trained assistant. Results: The mean exchange times for LMA, Cobra PLA, Air-Q, and SALT were as follows: 21, 23, 21, and 18, respectively for Scenario A; 23, 27, 22.5, and 21 for Scenario B; and 23, 28, 23, and 23 for Scenario C. The percent efficacy of SADs exchange with LMA, Cobra PLA, Air-Q and SALT were 98.7%, 94.9%, 100%, and 100% for scenario A; 98.7%, 88.6%, 98.7%, and 97.5% for scenario B; and 93.7%, 87.3%, 94.9%, and 93.7% for scenario C. Conclusions: In this model of pediatric resuscitation, the SAD exchange using an ETTI has (LMA, Cobra PLA, Air-Q and SALT) proved to be effective in paramedics with no previous experience. Furthermore, experimental findings indicated that SAD exchange can be achieved without interrupting chest compression.
- Is Part Of:
- Medicine. Volume 96:Issue 26(2017)
- Journal:
- Medicine
- Issue:
- Volume 96:Issue 26(2017)
- Issue Display:
- Volume 96, Issue 26 (2017)
- Year:
- 2017
- Volume:
- 96
- Issue:
- 26
- Issue Sort Value:
- 2017-0096-0026-0000
- Page Start:
- Page End:
- Publication Date:
- 2017-06
- Subjects:
- cardiopulmonary resuscitation -- child -- endotracheal intubation -- simulation -- supraglottic -- tracheal tube
Medicine -- Periodicals
Medicine -- Periodicals
Médecine -- Périodiques
Geneeskunde
Medicine
Periodicals
Periodicals
610.5 - Journal URLs:
- http://journals.lww.com/md-journal/pages/default.aspx ↗
http://gateway.ovid.com/ovidweb.cgi?T=JS&PAGE=toc&D=ovft&MODE=ovid&NEWS=N&AN=00002060-000000000-00000 ↗
http://journals.lww.com ↗ - DOI:
- 10.1097/MD.0000000000007177 ↗
- Languages:
- English
- ISSNs:
- 0025-7974
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5534.000000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 5034.xml