Measurement of Cochlear Implant Electrode Position From Intraoperative Post-insertion Skull Radiographs: A Validation Study. Issue 9 (October 2015)
- Record Type:
- Journal Article
- Title:
- Measurement of Cochlear Implant Electrode Position From Intraoperative Post-insertion Skull Radiographs: A Validation Study. Issue 9 (October 2015)
- Main Title:
- Measurement of Cochlear Implant Electrode Position From Intraoperative Post-insertion Skull Radiographs
- Authors:
- Svrakic, Maja
Friedmann, David R.
Berman, Phillip M.
Davis, Adam J.
Roland, J. Thomas
Svirsky, Mario A. - Abstract:
- Abstract : Objective: To validate a method of measuring angular depth of insertion (aDOI) as well as positional depth of each electrode contact in a cochlear implant by using intraoperative postinsertion skull radiographs. Study Design: Retrospective review. Setting: Tertiary referral center. Patients: Intraoperative postinsertion radiographs obtained from 18 cochlear implant recipients were chosen for analysis. One high-resolution computer tomography scan of the head with the electrode in place was also analyzed. One cadaveric temporal bone with an inserted electrode provided additional data for analysis. Intervention: aDOI and position of each electrode contact were measured from the radiographs using readily available software. High-resolution computer tomography imaging of the cochlea and electrode were reconstructed in three dimensions and used to simulate head rotation during intraoperative radiographs. The cadaveric temporal bone was imaged by x-ray at various acquisition angles. Main Outcome Measures: We evaluated the error introduced in measuring aDOI by assessing intra- and inter-rater variability. We also evaluated the error introduced by x-ray acquisition at nonstandardized angles by analyzing the three-dimensional construct and the cadaveric temporal bone. Results: The concordance correlation coefficients for intrarater (0.991) and inter-rater (0.996) variability in aDOI measurement were excellent. The error introduced by nonstandardized x-ray acquisition anglesAbstract : Objective: To validate a method of measuring angular depth of insertion (aDOI) as well as positional depth of each electrode contact in a cochlear implant by using intraoperative postinsertion skull radiographs. Study Design: Retrospective review. Setting: Tertiary referral center. Patients: Intraoperative postinsertion radiographs obtained from 18 cochlear implant recipients were chosen for analysis. One high-resolution computer tomography scan of the head with the electrode in place was also analyzed. One cadaveric temporal bone with an inserted electrode provided additional data for analysis. Intervention: aDOI and position of each electrode contact were measured from the radiographs using readily available software. High-resolution computer tomography imaging of the cochlea and electrode were reconstructed in three dimensions and used to simulate head rotation during intraoperative radiographs. The cadaveric temporal bone was imaged by x-ray at various acquisition angles. Main Outcome Measures: We evaluated the error introduced in measuring aDOI by assessing intra- and inter-rater variability. We also evaluated the error introduced by x-ray acquisition at nonstandardized angles by analyzing the three-dimensional construct and the cadaveric temporal bone. Results: The concordance correlation coefficients for intrarater (0.991) and inter-rater (0.996) variability in aDOI measurement were excellent. The error introduced by nonstandardized x-ray acquisition angles was only −12.5 degrees to +15.8 degrees even at the limits of clinically relevant head rotation. Conclusions: The intraoperative postinsertion radiograph is sufficient for estimating positional depth of electrode contacts and the aDOI. This measure is robust in the face of nonstandardized x-ray acquisition angles, and shows good intra- and inter-rater variability … (more)
- Is Part Of:
- Otology & neurotology. Volume 36:Issue 9(2015)
- Journal:
- Otology & neurotology
- Issue:
- Volume 36:Issue 9(2015)
- Issue Display:
- Volume 36, Issue 9 (2015)
- Year:
- 2015
- Volume:
- 36
- Issue:
- 9
- Issue Sort Value:
- 2015-0036-0009-0000
- Page Start:
- Page End:
- Publication Date:
- 2015-10
- Subjects:
- Cochlear implant -- Cochlear view -- Depth of insertion -- Intracochlear electrode position -- Postoperative radiograph
Otology -- Periodicals
Ear -- Diseases -- Periodicals
Skull base -- Surgery -- Periodicals
617.8005 - Journal URLs:
- http://www.otology-neurotology.com ↗
http://journals.lww.com ↗ - DOI:
- 10.1097/MAO.0000000000000852 ↗
- Languages:
- English
- ISSNs:
- 1531-7129
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 6313.528000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 5026.xml