VALIDATION OF AN ALGORITHM FOR NONMETALLIC INTRAOCULAR FOREIGN BODIES' COMPOSITION IDENTIFICATION BASED ON COMPUTED TOMOGRAPHY AND MAGNETIC RESONANCE IMAGING. Issue 9 (September 2015)
- Record Type:
- Journal Article
- Title:
- VALIDATION OF AN ALGORITHM FOR NONMETALLIC INTRAOCULAR FOREIGN BODIES' COMPOSITION IDENTIFICATION BASED ON COMPUTED TOMOGRAPHY AND MAGNETIC RESONANCE IMAGING. Issue 9 (September 2015)
- Main Title:
- VALIDATION OF AN ALGORITHM FOR NONMETALLIC INTRAOCULAR FOREIGN BODIES' COMPOSITION IDENTIFICATION BASED ON COMPUTED TOMOGRAPHY AND MAGNETIC RESONANCE IMAGING
- Authors:
- Moisseiev, Elad
Barequet, Dana
Zunz, Eran
Barak, Adiel
Mardor, Yael
Last, David
Goez, David
Segal, Zvi
Loewenstein, Anat - Abstract:
- Abstract : Purpose: To validate and evaluate the accuracy of an algorithm for the identification of nonmetallic intraocular foreign body composition based on computed tomography and magnetic resonance imaging. Methods: An algorithm for the identification of 10 nonmetallic materials based on computed tomography and magnetic resonance imaging has been previously determined in an ex vivo porcine model. Materials were classified into 4 groups (plastic, glass, stone, and wood). The algorithm was tested by 40 ophthalmologists, which completed a questionnaire including 10 sets of computed tomography and magnetic resonance images of eyes with intraocular foreign bodies and were asked to use the algorithm to identify their compositions. Rates of exact material identification and group identification were measured. Results: Exact material identification was achieved in 42.75% of the cases, and correct group identification in 65%. Using the algorithm, 6 of the materials were exactly identified by over 50% of the participants, and 7 were correctly classified according to their groups by over 75% of the materials. Discussion: The algorithm was validated and was found to enable correct identification of nonmetallic intraocular foreign body composition in the majority of cases. This is the first study to report and validate a clinical tool allowing intraocular foreign body composition based on their appearance in computed tomography and magnetic resonance imaging, which was previouslyAbstract : Purpose: To validate and evaluate the accuracy of an algorithm for the identification of nonmetallic intraocular foreign body composition based on computed tomography and magnetic resonance imaging. Methods: An algorithm for the identification of 10 nonmetallic materials based on computed tomography and magnetic resonance imaging has been previously determined in an ex vivo porcine model. Materials were classified into 4 groups (plastic, glass, stone, and wood). The algorithm was tested by 40 ophthalmologists, which completed a questionnaire including 10 sets of computed tomography and magnetic resonance images of eyes with intraocular foreign bodies and were asked to use the algorithm to identify their compositions. Rates of exact material identification and group identification were measured. Results: Exact material identification was achieved in 42.75% of the cases, and correct group identification in 65%. Using the algorithm, 6 of the materials were exactly identified by over 50% of the participants, and 7 were correctly classified according to their groups by over 75% of the materials. Discussion: The algorithm was validated and was found to enable correct identification of nonmetallic intraocular foreign body composition in the majority of cases. This is the first study to report and validate a clinical tool allowing intraocular foreign body composition based on their appearance in computed tomography and magnetic resonance imaging, which was previously impossible. Abstract : Supplemental Digital Content is Available in the Text.This is a validation study for an algorithm allowing identification of nonmetallic intraocular foreign body composition based on computed tomography and magnetic resonance imaging. Participating ophthalmologists achieved high rates of correct identification for most materials. This validation establishes an algorithm as the first reported clinical tool for identification of intraocular foreign body composition based on imaging characteristics. … (more)
- Is Part Of:
- Retina. Volume 35:Issue 9(2015:Sep.)
- Journal:
- Retina
- Issue:
- Volume 35:Issue 9(2015:Sep.)
- Issue Display:
- Volume 35, Issue 9 (2015)
- Year:
- 2015
- Volume:
- 35
- Issue:
- 9
- Issue Sort Value:
- 2015-0035-0009-0000
- Page Start:
- Page End:
- Publication Date:
- 2015-09
- Subjects:
- nonmetallic -- intraocular foreign body -- computed tomography -- magnetic resonance imaging -- validation -- algorithm
Retina -- Diseases -- Periodicals
Retinal Diseases
Vitreous Body
617.735 - Journal URLs:
- http://journals.lww.com/retinajournal/pages/default.aspx ↗
http://journals.lww.com ↗ - DOI:
- 10.1097/IAE.0000000000000556 ↗
- Languages:
- English
- ISSNs:
- 0275-004X
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 7785.510300
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 5012.xml