Improved Detection of Hypervascular Liver Lesions With CAIPIRINHA–Dixon–TWIST–Volume-Interpolated Breath-Hold Examination. Issue 3 (March 2015)
- Record Type:
- Journal Article
- Title:
- Improved Detection of Hypervascular Liver Lesions With CAIPIRINHA–Dixon–TWIST–Volume-Interpolated Breath-Hold Examination. Issue 3 (March 2015)
- Main Title:
- Improved Detection of Hypervascular Liver Lesions With CAIPIRINHA–Dixon–TWIST–Volume-Interpolated Breath-Hold Examination
- Authors:
- Kazmierczak, Philipp M.
Theisen, Daniel
Thierfelder, Kolja M.
Sommer, Wieland H.
Reiser, Maximilian F.
Notohamiprodjo, Mike
Nikolaou, Konstantin - Abstract:
- Abstract : Objectives: The aim of this study was to assess the diagnostic performance of a dynamic, multiphasic contrast-enhanced volume-interpolated sequence with advanced parallel imaging techniques, Dixon fat saturation, and view sharing with 5 hepatic arterial subphases for the detection of focal liver lesions. Materials and Methods: Twenty-four consecutive patients (13 females, 11 males; mean [SD] age, 58 [15] years) with focal liver lesions were included in this prospective study. The examination was performed at a 3-T magnetic resonance imaging system (MAGNETOM Skyra; Siemens Healthcare, Erlangen, Germany). Five dynamic arterial subphases with a temporal resolution of 2.6 seconds, starting 17 seconds after injection of the hepatobiliary contrast agent gadolinium ethoxybenzyl diethylenetriaminepentaacetic acid (Eovist; Bayer HealthCare, Leverkusen, Germany), were acquired using an accelerated parallel imaging volume-interpolated sequence with view sharing (multiarterial controlled aliasing in parallel imaging results in higher acceleration–Dixon–time-resolved angiography with interleaved stochastic trajectories–volumetric interpolated breath-hold examination [MA-CDT-VIBE]). The fourth of the 5 arterial acquisition phases (ie, at 24.8 seconds after the start of contrast agent injection) was considered the equivalent of a standard hepatic arterial phase (equivalent standard arterial phase [ESAP]). The diagnostic value of all 5 dynamic arterial phases for the detection ofAbstract : Objectives: The aim of this study was to assess the diagnostic performance of a dynamic, multiphasic contrast-enhanced volume-interpolated sequence with advanced parallel imaging techniques, Dixon fat saturation, and view sharing with 5 hepatic arterial subphases for the detection of focal liver lesions. Materials and Methods: Twenty-four consecutive patients (13 females, 11 males; mean [SD] age, 58 [15] years) with focal liver lesions were included in this prospective study. The examination was performed at a 3-T magnetic resonance imaging system (MAGNETOM Skyra; Siemens Healthcare, Erlangen, Germany). Five dynamic arterial subphases with a temporal resolution of 2.6 seconds, starting 17 seconds after injection of the hepatobiliary contrast agent gadolinium ethoxybenzyl diethylenetriaminepentaacetic acid (Eovist; Bayer HealthCare, Leverkusen, Germany), were acquired using an accelerated parallel imaging volume-interpolated sequence with view sharing (multiarterial controlled aliasing in parallel imaging results in higher acceleration–Dixon–time-resolved angiography with interleaved stochastic trajectories–volumetric interpolated breath-hold examination [MA-CDT-VIBE]). The fourth of the 5 arterial acquisition phases (ie, at 24.8 seconds after the start of contrast agent injection) was considered the equivalent of a standard hepatic arterial phase (equivalent standard arterial phase [ESAP]). The diagnostic value of all 5 dynamic arterial phases for the detection of focal liver lesions, as compared with the single ESAP, was judged in 2 independent consensus readings. The 2 consensus reading groups were blinded to each others' results. The complete, comprehensive multisequence magnetic resonance imaging examination, including T1-weighted, T2-weighted, and multiphasic contrast-enhanced sequences, served as the standard of reference for lesion detection. Results: Forty-six percent of the patients (11/24) had hypervascular lesions. In 79 % of all patients (19/24), the best arterial parenchymal contrast of one of the MA-CDT-VIBE acquisition phases was considered better than that of the ESAP. In one third of all cases (8/24 for the first and 6/24 for the second consensus reading), MA-CDT-VIBE showed an improved lesion detection rate compared with ESAP, especially in hypervascular lesions (4/11, representing 36% of all patients with hypervascular lesions). There was a high degree of interrater agreement between the 2 consensus reading groups (the Cohen κ, 0.71–1.00; P < 0.001). Conclusions: Compared with a standard hepatic arterial phase, MA-CDT-VIBE with 5 hepatic arterial subphases demonstrated greater diagnostic accuracy for the detection of hypervascular focal liver lesions and provided a robust and optimized hepatic arterial acquisition phase. … (more)
- Is Part Of:
- Investigative radiology. Volume 50:Issue 3(2015:Mar.)
- Journal:
- Investigative radiology
- Issue:
- Volume 50:Issue 3(2015:Mar.)
- Issue Display:
- Volume 50, Issue 3 (2015)
- Year:
- 2015
- Volume:
- 50
- Issue:
- 3
- Issue Sort Value:
- 2015-0050-0003-0000
- Page Start:
- Page End:
- Publication Date:
- 2015-03
- Subjects:
- multiarterial liver MRI -- focal liver lesions -- advanced parallel imaging -- CAIPIRINHA-Dixon-TWIST-VIBE
Diagnosis, Radioscopic -- Periodicals
Radiology, Medical -- Periodicals
616.0757 - Journal URLs:
- http://journals.lww.com/investigativeradiology/pages/default.aspx ↗
http://journals.lww.com ↗ - DOI:
- 10.1097/RLI.0000000000000118 ↗
- Languages:
- English
- ISSNs:
- 0020-9996
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4560.350000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 5018.xml