Comparison of Intraplatelet Reactive Oxygen Species, Mitochondrial Damage, and Platelet Apoptosis After Implantation of Three Continuous Flow Left Ventricular Assist Devices: HeartMate II, Jarvik 2000, and HeartWare. Issue 3 (May 2015)
- Record Type:
- Journal Article
- Title:
- Comparison of Intraplatelet Reactive Oxygen Species, Mitochondrial Damage, and Platelet Apoptosis After Implantation of Three Continuous Flow Left Ventricular Assist Devices: HeartMate II, Jarvik 2000, and HeartWare. Issue 3 (May 2015)
- Main Title:
- Comparison of Intraplatelet Reactive Oxygen Species, Mitochondrial Damage, and Platelet Apoptosis After Implantation of Three Continuous Flow Left Ventricular Assist Devices
- Authors:
- Mondal, Nandan K.
Sorensen, Erik N.
Feller, Erika D.
Pham, Si M.
Griffith, Bartley P.
Wu, Zhongjun J. - Abstract:
- Abstract : Differences in device design may have an effect on platelet damage and associated clinical complications. We aimed to compare device-specific platelet functionality in 26 heart failure patients supported with three continuous-flow left ventricular assist devices: HeartMate II (n = 8), Jarvik 2000 (n = 9), and HeartWare (n = 9). Intraplatelet reactive oxygen species (ROS) generation, mitochondrial damage, and platelet apoptosis were compared between device types before and after the implantation at every week up to 1 month. Overall, the baseline characteristics, demographics, routine laboratory values were comparable between the three device groups. Intraplatelet ROS, mitochondrial damage, and platelet apoptosis significantly elevated in the HeartWare group in comparison with the other two device groups after implantation. The major bleeding, infections, systemic inflammatory response syndrome, and right ventricular failure were found to be more common among the HeartWare group than others. Intraplatelet ROS and platelet damage levels were returned to baseline in both the HeartMate II and the Jarvik groups, whereas in HeartWare group they remained elevated. The patients with the Jarvik and the HeartMate II experienced less clinical complications and the platelet functionality is not compromised by these devices. Data from this study suggests that the continuous-flow left ventricular assist devices design may exert different effects on platelet function.
- Is Part Of:
- ASAIO journal. Volume 61:Issue 3(2015)
- Journal:
- ASAIO journal
- Issue:
- Volume 61:Issue 3(2015)
- Issue Display:
- Volume 61, Issue 3 (2015)
- Year:
- 2015
- Volume:
- 61
- Issue:
- 3
- Issue Sort Value:
- 2015-0061-0003-0000
- Page Start:
- Page End:
- Publication Date:
- 2015-05
- Subjects:
- heart failure -- left ventricular assist devices -- intraplatelet reactive oxygen species -- mitochondrial damage -- platelet apoptosis
Artificial organs -- Periodicals
617 - Journal URLs:
- http://journals.lww.com/asaiojournal/pages/default.aspx ↗
http://journals.lww.com ↗ - DOI:
- 10.1097/MAT.0000000000000208 ↗
- Languages:
- English
- ISSNs:
- 1058-2916
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 1738.840500
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 5023.xml