Neuroprotective Strategies Can Prevent Permanent Paraplegia in the Majority of Patients Who Develop Spinal Cord Ischaemia After Endovascular Repair of Thoracoabdominal Aortic Aneurysms. Issue 5 (November 2015)
- Record Type:
- Journal Article
- Title:
- Neuroprotective Strategies Can Prevent Permanent Paraplegia in the Majority of Patients Who Develop Spinal Cord Ischaemia After Endovascular Repair of Thoracoabdominal Aortic Aneurysms. Issue 5 (November 2015)
- Main Title:
- Neuroprotective Strategies Can Prevent Permanent Paraplegia in the Majority of Patients Who Develop Spinal Cord Ischaemia After Endovascular Repair of Thoracoabdominal Aortic Aneurysms
- Authors:
- Rossi, S.H.
Patel, A.
Saha, P.
Gwozdz, A.
Salter, R.
Gkoutzios, P.
Carrell, T.
Abisi, S.
Modarai, B. - Abstract:
- Abstract : Objectives: Spinal cord ischaemia (SCI) following endovascular thoracoabdominal aortic aneurysm (TAAA) repair is a devastating and unpredictable complication. This study describes a single unit's experience of SCI in patients who have had endovascular TAAA repair. Methods: A prospectively maintained database of patients having endovascular TAAA repair using branched and fenestrated stent grafts between 2008 and 2014 at a single high volume centre was reviewed. Patients who developed neurological symptoms and signs related to SCI were identified and factors associated with onset and recovery of neurology were analysed. Results: Sixty-nine patients (median age 73 years, 52 male; Crawford classification type I [ n = 4], type II [ n = 11], type III [ n = 33], type IV [ n = 14], type V [ n = 7]) underwent endovascular TAAA repair. Twelve patients developed neurological symptoms/signs related to SCI but this was successfully reversed in eight patients, leaving four (5.8%) with permanent paraplegia. The median length of aorta covered was not significantly different in the 12 patients who developed SCI compared with the cohort that did not. Eleven of the patients who developed SCI had an intraoperative mean arterial pressure (MAP) below 80 mmHg. Cutaneous atheroemboli were noted in half of the patients in the SCI group compared with 11% of the non-SCI group ( p < .05). Strategies used to reverse SCI included raising MAP, cerebrospinal fluid drainage, angioplasty ofAbstract : Objectives: Spinal cord ischaemia (SCI) following endovascular thoracoabdominal aortic aneurysm (TAAA) repair is a devastating and unpredictable complication. This study describes a single unit's experience of SCI in patients who have had endovascular TAAA repair. Methods: A prospectively maintained database of patients having endovascular TAAA repair using branched and fenestrated stent grafts between 2008 and 2014 at a single high volume centre was reviewed. Patients who developed neurological symptoms and signs related to SCI were identified and factors associated with onset and recovery of neurology were analysed. Results: Sixty-nine patients (median age 73 years, 52 male; Crawford classification type I [ n = 4], type II [ n = 11], type III [ n = 33], type IV [ n = 14], type V [ n = 7]) underwent endovascular TAAA repair. Twelve patients developed neurological symptoms/signs related to SCI but this was successfully reversed in eight patients, leaving four (5.8%) with permanent paraplegia. The median length of aorta covered was not significantly different in the 12 patients who developed SCI compared with the cohort that did not. Eleven of the patients who developed SCI had an intraoperative mean arterial pressure (MAP) below 80 mmHg. Cutaneous atheroemboli were noted in half of the patients in the SCI group compared with 11% of the non-SCI group ( p < .05). Strategies used to reverse SCI included raising MAP, cerebrospinal fluid drainage, angioplasty of stenosed internal iliac arteries, and restoring perfusion to the aneurysm sac. Conclusions: This series highlights some of the risk factors associated with the development of SCI after endovascular repair of TAAAs. It also illustrates the importance of a dedicated institutional protocol aimed at ensuring the early diagnosis of SCI and prompt intervention to reverse permanent paraplegia in the majority of cases. … (more)
- Is Part Of:
- European journal of vascular and endovascular surgery. Volume 50:Issue 5(2015:Nov)
- Journal:
- European journal of vascular and endovascular surgery
- Issue:
- Volume 50:Issue 5(2015:Nov)
- Issue Display:
- Volume 50, Issue 5 (2016)
- Year:
- 2016
- Volume:
- 50
- Issue:
- 5
- Issue Sort Value:
- 2016-0050-0005-0000
- Page Start:
- 599
- Page End:
- 607
- Publication Date:
- 2015-11
- Subjects:
- Spinal cord ischaemia -- Endovascular -- Thoracoabdominal aneurysm
Blood-vessels -- Endoscopic surgery -- Periodicals
Blood-vessels -- Surgery -- Periodicals
Vascular Surgical Procedures -- Periodicals
Vascular Surgical Procedures -- methods -- Periodicals
Vaisseaux sanguins -- Chirurgie -- Périodiques
Vaisseaux sanguins -- Chirurgie endoscopique -- Périodiques
Blood-vessels -- Endoscopic surgery
Blood-vessels -- Surgery
Endoscopy
Electronic journals
Periodicals
Electronic journals
617.413005 - Journal URLs:
- http://firstsearch.oclc.org ↗
http://firstsearch.oclc.org/journal=1078-5884;screen=info;ECOIP ↗
http://www.harcourt-international.com/journals/ejvs/ ↗
http://www.harcourt-international.com/journals/ejvx/ ↗
http://www.clinicalkey.com/dura/browse/journalIssue/10785884 ↗
http://www.clinicalkey.com.au/dura/browse/journalIssue/10785884 ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.ejvs.2015.07.031 ↗
- Languages:
- English
- ISSNs:
- 1078-5884
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3829.747280
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 4994.xml