Standardisation of bioelectrical impedance analysis for the estimation of body composition in healthy paediatric populations: a systematic review. (18th August 2017)
- Record Type:
- Journal Article
- Title:
- Standardisation of bioelectrical impedance analysis for the estimation of body composition in healthy paediatric populations: a systematic review. (18th August 2017)
- Main Title:
- Standardisation of bioelectrical impedance analysis for the estimation of body composition in healthy paediatric populations: a systematic review
- Authors:
- Brantlov, Steven
Jødal, Lars
Lange, Aksel
Rittig, Søren
Ward, Leigh C. - Abstract:
- Abstract: Background: Bioelectrical impedance analysis (BIA) requires a high degree of standardisation in order to ensure valid and reproducible impedance measurements. The overall aim of this review was to study the degree to which BIA papers conducted in healthy paediatric populations (aged 0–17 years) were standardised. Methods: Literature was identified on the basis of a systematic search of internationally-recognised electronic databases and hand searching of the reference lists of the included papers in order to identify additional relevant papers. The review was limited to lead-type BIA devices for whole-body, segmental- and focal impedance measurements. In total, 71 papers published between 1988 and 2016 were included. To evaluate the degree of standardisation of the papers, a recently published review detailing critical factors that may impact on BIA measurements in children was used as a model for structuring and extracting data. Results: There was a general lack of BIA standardisation, or its reporting, in the papers under review, which hinders comparison of data between studies and could potentially lead to erroneous measurements. Conclusions: If the BIA technique should be accepted clinically for routine use in paediatric populations, there is a need for an increased focus on the importance of improved standardisation and its reporting in future studies. Consequently, this review contains recommendations for performing and reporting BIA measurements in aAbstract: Background: Bioelectrical impedance analysis (BIA) requires a high degree of standardisation in order to ensure valid and reproducible impedance measurements. The overall aim of this review was to study the degree to which BIA papers conducted in healthy paediatric populations (aged 0–17 years) were standardised. Methods: Literature was identified on the basis of a systematic search of internationally-recognised electronic databases and hand searching of the reference lists of the included papers in order to identify additional relevant papers. The review was limited to lead-type BIA devices for whole-body, segmental- and focal impedance measurements. In total, 71 papers published between 1988 and 2016 were included. To evaluate the degree of standardisation of the papers, a recently published review detailing critical factors that may impact on BIA measurements in children was used as a model for structuring and extracting data. Results: There was a general lack of BIA standardisation, or its reporting, in the papers under review, which hinders comparison of data between studies and could potentially lead to erroneous measurements. Conclusions: If the BIA technique should be accepted clinically for routine use in paediatric populations, there is a need for an increased focus on the importance of improved standardisation and its reporting in future studies. Consequently, this review contains recommendations for performing and reporting BIA measurements in a standardised manner. … (more)
- Is Part Of:
- Journal of medical engineering & technology. Volume 41:Number 6(2017)
- Journal:
- Journal of medical engineering & technology
- Issue:
- Volume 41:Number 6(2017)
- Issue Display:
- Volume 41, Issue 6 (2017)
- Year:
- 2017
- Volume:
- 41
- Issue:
- 6
- Issue Sort Value:
- 2017-0041-0006-0000
- Page Start:
- 460
- Page End:
- 479
- Publication Date:
- 2017-08-18
- Subjects:
- Bioelectrical impedance analysis -- body composition -- standardisation -- healthy -- paediatrics
Biomedical engineering -- Periodicals
Medical technology -- Periodicals
610.28 - Journal URLs:
- http://informahealthcare.com/journal/jmt ↗
http://www.tandfonline.com/toc/ijmt20/current ↗
http://informahealthcare.com ↗
http://www.tandf.co.uk/journals/titles/03091902.asp ↗ - DOI:
- 10.1080/03091902.2017.1333165 ↗
- Languages:
- English
- ISSNs:
- 0309-1902
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5017.057000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File: