Validity of heart rate measurements by the Garmin Forerunner 225 at different walking intensities. (18th August 2017)
- Record Type:
- Journal Article
- Title:
- Validity of heart rate measurements by the Garmin Forerunner 225 at different walking intensities. (18th August 2017)
- Main Title:
- Validity of heart rate measurements by the Garmin Forerunner 225 at different walking intensities
- Authors:
- Claes, Jomme
Buys, Roselien
Avila, Andrea
Finlay, Dewar
Kennedy, Alan
Guldenring, Daniel
Budts, Werner
Cornelissen, Véronique - Abstract:
- Abstract: The accuracy of wrist worn heart rate monitors based on photoplethysmography (PPG) is not fully clinically accepted. Therefore, we aimed to validate heart rate measurements of a commercially available PPG heart rate monitor, i.e. the Garmin Forerunner ® 225. Twelve healthy volunteers (six women; mean age: 28 years) performed a treadmill protocol consisting of: five minutes sitting, five minutes standing, 10 minutes walking at 4 km/h, 10 minutes walking at a gradient of 5% and intensity of 4–6 metabolic equivalents (METs), 10 minutes walking at a gradient of 8% and intensity of seven METs or more. Walking speeds were individually determined. Walking bouts were separated by a standardised five minute rest period. Heart rate was measured as the average of the last three minutes standing and of each walking bout. A three lead patch-based electrocardiogram (ECG; Zensor ® ) was used as criterion method. Statistical analyses included Pearson's correlation (r), paired t-tests, root mean squared error (RMSE) and Bland?Altman plots. The mean values per three minutes of every condition did not differ significantly between the Garmin Forerunner ® 225 and the Zensor ® . RMSE was 3.01 beats per minute (bpm) or 2.89%. The Bland–Altman bias was 1.57 bpm. Limits of agreement (LoA) were wide, ranging from 32.53 to 29.40 bpm. However, Pearson's r ranged from 0.650 to 0.868 suggesting moderate to strong validity. Generally, mean heart rates, r values, RMSE and the Bland–Altman biasAbstract: The accuracy of wrist worn heart rate monitors based on photoplethysmography (PPG) is not fully clinically accepted. Therefore, we aimed to validate heart rate measurements of a commercially available PPG heart rate monitor, i.e. the Garmin Forerunner ® 225. Twelve healthy volunteers (six women; mean age: 28 years) performed a treadmill protocol consisting of: five minutes sitting, five minutes standing, 10 minutes walking at 4 km/h, 10 minutes walking at a gradient of 5% and intensity of 4–6 metabolic equivalents (METs), 10 minutes walking at a gradient of 8% and intensity of seven METs or more. Walking speeds were individually determined. Walking bouts were separated by a standardised five minute rest period. Heart rate was measured as the average of the last three minutes standing and of each walking bout. A three lead patch-based electrocardiogram (ECG; Zensor ® ) was used as criterion method. Statistical analyses included Pearson's correlation (r), paired t-tests, root mean squared error (RMSE) and Bland?Altman plots. The mean values per three minutes of every condition did not differ significantly between the Garmin Forerunner ® 225 and the Zensor ® . RMSE was 3.01 beats per minute (bpm) or 2.89%. The Bland–Altman bias was 1.57 bpm. Limits of agreement (LoA) were wide, ranging from 32.53 to 29.40 bpm. However, Pearson's r ranged from 0.650 to 0.868 suggesting moderate to strong validity. Generally, mean heart rates, r values, RMSE and the Bland–Altman bias indicated good overall agreement in this sample of healthy adults, but wide LoA are making it difficult to trust individual measurements. … (more)
- Is Part Of:
- Journal of medical engineering & technology. Volume 41:Number 6(2017)
- Journal:
- Journal of medical engineering & technology
- Issue:
- Volume 41:Number 6(2017)
- Issue Display:
- Volume 41, Issue 6 (2017)
- Year:
- 2017
- Volume:
- 41
- Issue:
- 6
- Issue Sort Value:
- 2017-0041-0006-0000
- Page Start:
- 480
- Page End:
- 485
- Publication Date:
- 2017-08-18
- Subjects:
- Validity -- Garmin -- heart rate -- photoplethysmography -- sports watch
Biomedical engineering -- Periodicals
Medical technology -- Periodicals
610.28 - Journal URLs:
- http://informahealthcare.com/journal/jmt ↗
http://www.tandfonline.com/toc/ijmt20/current ↗
http://informahealthcare.com ↗
http://www.tandf.co.uk/journals/titles/03091902.asp ↗ - DOI:
- 10.1080/03091902.2017.1333166 ↗
- Languages:
- English
- ISSNs:
- 0309-1902
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5017.057000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 4934.xml