Safety and Accuracy of Endovascular Aneurysm Repair Without Pre-operative and Intra-operative Contrast Agent. Issue 3 (March 2015)
- Record Type:
- Journal Article
- Title:
- Safety and Accuracy of Endovascular Aneurysm Repair Without Pre-operative and Intra-operative Contrast Agent. Issue 3 (March 2015)
- Main Title:
- Safety and Accuracy of Endovascular Aneurysm Repair Without Pre-operative and Intra-operative Contrast Agent
- Authors:
- Kaladji, A.
Dumenil, A.
Mahé, G.
Castro, M.
Cardon, A.
Lucas, A.
Haigron, P. - Abstract:
- Abstract : Background: Severe chronic kidney disease is a major limitation for endovascular aortic aneurysm repair (EVAR). The aim of this study is to assess the safety and accuracy of fusion imaging, when performing EVAR in the absence of pre- and intra-operative contrast agents. Methods: From October 2013 to February 2014, every patient requiring EVAR and presenting with severe chronic renal impairment underwent a specific pre-operative imaging assessment, based on a non-enhanced CT scan. Centrelines were manually extracted and key points were placed at the landing zones. In house software makes it possible to artificially enhance the contrast between vascular structures and the surrounding tissue, by increasing the values attributed to the vascular structure voxels (500 Hounsfield units). EVAR was performed in a hybrid room (Zeego, Siemens), and the artificially enhanced CT scan was used for the construction of fusion imaging. The 3D vascular volume, together with the centrelines and key points, was overlaid onto the 2D live fluoroscopic image. Results: Six patients (mean age 77.1 years) were treated by EVAR (5 abdominal aneurysms and 1 thoracic aneurysm), using fusion imaging without a contrast agent. The median pre-operative estimated glomerular filtration rate (eGFR) was 17.5 mL/min/1.73 m 2 . No contrast was used during the procedure. No intra-operative endoleak was observed on the duplex scan. No deterioration was observed in the eGFR at 1 week (eGFR = 21.7, pAbstract : Background: Severe chronic kidney disease is a major limitation for endovascular aortic aneurysm repair (EVAR). The aim of this study is to assess the safety and accuracy of fusion imaging, when performing EVAR in the absence of pre- and intra-operative contrast agents. Methods: From October 2013 to February 2014, every patient requiring EVAR and presenting with severe chronic renal impairment underwent a specific pre-operative imaging assessment, based on a non-enhanced CT scan. Centrelines were manually extracted and key points were placed at the landing zones. In house software makes it possible to artificially enhance the contrast between vascular structures and the surrounding tissue, by increasing the values attributed to the vascular structure voxels (500 Hounsfield units). EVAR was performed in a hybrid room (Zeego, Siemens), and the artificially enhanced CT scan was used for the construction of fusion imaging. The 3D vascular volume, together with the centrelines and key points, was overlaid onto the 2D live fluoroscopic image. Results: Six patients (mean age 77.1 years) were treated by EVAR (5 abdominal aneurysms and 1 thoracic aneurysm), using fusion imaging without a contrast agent. The median pre-operative estimated glomerular filtration rate (eGFR) was 17.5 mL/min/1.73 m 2 . No contrast was used during the procedure. No intra-operative endoleak was observed on the duplex scan. No deterioration was observed in the eGFR at 1 week (eGFR = 21.7, p = .49), nor at 1 month follow up (eGFR = 21, p = .28). The stent graft positioning error was assessed in terms of the difference between the effective and planned landing zones, measured on pre- and post-operative CT scans. The mean error was 1.3 mm at the proximal landing zone, and 6.5 mm at the distal landing zone. Conclusion: EVAR without the use of pre-operative and intra-operative contrast agents appears to be safe and accurate for patients with severe chronic kidney disease. … (more)
- Is Part Of:
- European journal of vascular and endovascular surgery. Volume 49:Issue 3(2015:Mar.)
- Journal:
- European journal of vascular and endovascular surgery
- Issue:
- Volume 49:Issue 3(2015:Mar.)
- Issue Display:
- Volume 49, Issue 3 (2015)
- Year:
- 2015
- Volume:
- 49
- Issue:
- 3
- Issue Sort Value:
- 2015-0049-0003-0000
- Page Start:
- 255
- Page End:
- 261
- Publication Date:
- 2015-03
- Subjects:
- Augmented reality -- Contrast agent -- CT scan -- EVAR -- Fusion imaging
Blood-vessels -- Endoscopic surgery -- Periodicals
Blood-vessels -- Surgery -- Periodicals
Vascular Surgical Procedures -- Periodicals
Vascular Surgical Procedures -- methods -- Periodicals
Vaisseaux sanguins -- Chirurgie -- Périodiques
Vaisseaux sanguins -- Chirurgie endoscopique -- Périodiques
Blood-vessels -- Endoscopic surgery
Blood-vessels -- Surgery
Endoscopy
Electronic journals
Periodicals
Electronic journals
617.413005 - Journal URLs:
- http://firstsearch.oclc.org ↗
http://firstsearch.oclc.org/journal=1078-5884;screen=info;ECOIP ↗
http://www.harcourt-international.com/journals/ejvs/ ↗
http://www.harcourt-international.com/journals/ejvx/ ↗
http://www.clinicalkey.com/dura/browse/journalIssue/10785884 ↗
http://www.clinicalkey.com.au/dura/browse/journalIssue/10785884 ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.ejvs.2014.12.003 ↗
- Languages:
- English
- ISSNs:
- 1078-5884
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3829.747280
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 4940.xml