Radiation safety and ergonomics in the electrophysiology laboratory: update on recent advances. (January 2016)
- Record Type:
- Journal Article
- Title:
- Radiation safety and ergonomics in the electrophysiology laboratory: update on recent advances. (January 2016)
- Main Title:
- Radiation safety and ergonomics in the electrophysiology laboratory
- Authors:
- Nair, Girish M.
Nery, Pablo B.
Redpath, Calum J.
Sadek, Mouhannad M.
Birnie, David H. - Abstract:
- Abstract : Purpose of review: Risks associated with exposure to ionizing radiation in patients undergoing electrophysiology procedures and interventional cardiac electrophysiologists performing these procedures are a serious concern. Strategies to reduce radiation exposure are of obvious importance. In addition, interventional cardiac electrophysiologists have to perform procedures wearing heavy lead protection for prolonged periods, making them prone to cervical and lumbar spinal injuries. Recent findings: Recently developed technologies, such as low-exposure radiographic imaging, novel radiographic imaging protection systems, nonfluoroscopic mapping systems using image integration, and remote catheter manipulation systems have been successful in reducing ionizing radiation exposure in the electrophysiology laboratory. The efficacy and safety of these technologies are being evaluated in clinical trials. In addition, economic analyses are being performed to evaluate these novel systems. The use of nonweight-bearing radiation protection devices and ergonomic design of the electrophysiology laboratory aim to reduce the incidence of occupational injuries in interventional cardiac electrophysiologists. Summary: There is need for ongoing development and evaluation of new technologies to minimize exposure to ionizing radiation during electrophysiologic procedures. In addition, ergonomic planning of the electrophysiology laboratory and training of interventional cardiacAbstract : Purpose of review: Risks associated with exposure to ionizing radiation in patients undergoing electrophysiology procedures and interventional cardiac electrophysiologists performing these procedures are a serious concern. Strategies to reduce radiation exposure are of obvious importance. In addition, interventional cardiac electrophysiologists have to perform procedures wearing heavy lead protection for prolonged periods, making them prone to cervical and lumbar spinal injuries. Recent findings: Recently developed technologies, such as low-exposure radiographic imaging, novel radiographic imaging protection systems, nonfluoroscopic mapping systems using image integration, and remote catheter manipulation systems have been successful in reducing ionizing radiation exposure in the electrophysiology laboratory. The efficacy and safety of these technologies are being evaluated in clinical trials. In addition, economic analyses are being performed to evaluate these novel systems. The use of nonweight-bearing radiation protection devices and ergonomic design of the electrophysiology laboratory aim to reduce the incidence of occupational injuries in interventional cardiac electrophysiologists. Summary: There is need for ongoing development and evaluation of new technologies to minimize exposure to ionizing radiation during electrophysiologic procedures. In addition, ergonomic planning of the electrophysiology laboratory and training of interventional cardiac electrophysiologists are crucial to occupational injury prevention. … (more)
- Is Part Of:
- Current opinion in cardiology. Volume 31:Number 1(2016:Jan.)
- Journal:
- Current opinion in cardiology
- Issue:
- Volume 31:Number 1(2016:Jan.)
- Issue Display:
- Volume 31, Issue 1 (2016)
- Year:
- 2016
- Volume:
- 31
- Issue:
- 1
- Issue Sort Value:
- 2016-0031-0001-0000
- Page Start:
- Page End:
- Publication Date:
- 2016-01
- Subjects:
- cardiac electrophysiology -- catheter ablation -- ergonomic design -- ionizing radiation -- occupational injury prevention -- radiation protection
Cardiology -- Periodicals
Cardiology -- Periodicals
Heart Diseases -- Periodicals
Cardiology
Periodicals
616.12 - Journal URLs:
- http://journals.lww.com/co-cardiology/pages/default.aspx ↗
http://ovidsp.ovid.com/ovidweb.cgi?T=JS&NEWS=n&CSC=Y&PAGE=toc&D=yrovft&AN=00001573-000000000-00000 ↗
http://journals.lww.com/pages/default.aspx ↗
http://firstsearch.oclc.org ↗
http://firstsearch.oclc.org/journal=0268-4705;screen=info;ECOIP ↗
http://www.co-cardiology.com ↗ - DOI:
- 10.1097/HCO.0000000000000246 ↗
- Languages:
- English
- ISSNs:
- 0268-4705
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3500.773000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 4950.xml