Clinical Epidemiology of Extubation Failure in the Pediatric Cardiac ICU: A Report From the Pediatric Cardiac Critical Care Consortium*. Issue 9 (November 2015)
- Record Type:
- Journal Article
- Title:
- Clinical Epidemiology of Extubation Failure in the Pediatric Cardiac ICU: A Report From the Pediatric Cardiac Critical Care Consortium*. Issue 9 (November 2015)
- Main Title:
- Clinical Epidemiology of Extubation Failure in the Pediatric Cardiac ICU
- Authors:
- Gaies, Michael
Tabbutt, Sarah
Schwartz, Steven M.
Bird, Geoffrey L.
Alten, Jeffrey A.
Shekerdemian, Lara S.
Klugman, Darren
Thiagarajan, Ravi R.
Gaynor, J. William
Jacobs, Jeffrey P.
Nicolson, Susan C.
Donohue, Janet E.
Yu, Sunkyung
Pasquali, Sara K.
Cooper, David S. - Abstract:
- Abstract : Objective: To describe the clinical epidemiology of extubation failure in a multicenter cohort of patients treated in pediatric cardiac ICUs. Design: Retrospective cohort study using prospectively collected clinical registry data. Setting: Pediatric Cardiac Critical Care Consortium registry. Patients: All patients admitted to the CICU at Pediatric Cardiac Critical Care Consortium hospitals. Interventions: None. Measurements and Main Results: Analysis of all mechanical ventilation episodes in the registry from October 1, 2013, to July 31, 2014. The primary outcome of extubation failure was reintubation less than 48 hours after planned extubation. Repeated-measures analysis using generalized estimating equations to account for within patient and center correlation was performed to identify risk factors for extubation failure. Adjusted extubation failure rates for each hospital were calculated using logistic regression controlling for patient factors. Of 1, 734 mechanical ventilation episodes (1, 478 patients at eight hospitals) ending in a planned extubation, there were 100 extubation failures (5.8%). In multivariable analysis, only longer duration of mechanical ventilation was significantly associated with extubation failure ( p = 0.01); the failure rate was 4% when ventilated less than 24 hours, 9% after 24 hours, and 13% after 7 days. For 503 patients intubated and extubated in the cardiac operating room, 15 patients (3%) failed extubation within 48 hours (12Abstract : Objective: To describe the clinical epidemiology of extubation failure in a multicenter cohort of patients treated in pediatric cardiac ICUs. Design: Retrospective cohort study using prospectively collected clinical registry data. Setting: Pediatric Cardiac Critical Care Consortium registry. Patients: All patients admitted to the CICU at Pediatric Cardiac Critical Care Consortium hospitals. Interventions: None. Measurements and Main Results: Analysis of all mechanical ventilation episodes in the registry from October 1, 2013, to July 31, 2014. The primary outcome of extubation failure was reintubation less than 48 hours after planned extubation. Repeated-measures analysis using generalized estimating equations to account for within patient and center correlation was performed to identify risk factors for extubation failure. Adjusted extubation failure rates for each hospital were calculated using logistic regression controlling for patient factors. Of 1, 734 mechanical ventilation episodes (1, 478 patients at eight hospitals) ending in a planned extubation, there were 100 extubation failures (5.8%). In multivariable analysis, only longer duration of mechanical ventilation was significantly associated with extubation failure ( p = 0.01); the failure rate was 4% when ventilated less than 24 hours, 9% after 24 hours, and 13% after 7 days. For 503 patients intubated and extubated in the cardiac operating room, 15 patients (3%) failed extubation within 48 hours (12 within 24 hr). Case-mix-adjusted extubation failure rates ranged from 1.1% to 9.8% across hospitals. Patients failing extubation had greater median cardiac ICU length of stay (15 vs 3 d; p < 0.001) and in-hospital mortality (7.9 vs 1.2%; p < 0.001). Conclusions: Though extubation failure is uncommon overall, there may be opportunities to improve extubation readiness assessment in patients ventilated more than 24 hours. These data suggest that extubation in the operating room after cardiac surgery can be done with a low failure rate. We observed variation in extubation failure rates across hospitals, and future investigation must elucidate the optimal strategies of high-performing centers to reduce ventilation time while limiting extubation failures. Abstract : Supplemental Digital Content is available in the text. … (more)
- Is Part Of:
- Pediatric critical care medicine. Volume 16:Issue 9(2015)
- Journal:
- Pediatric critical care medicine
- Issue:
- Volume 16:Issue 9(2015)
- Issue Display:
- Volume 16, Issue 9 (2015)
- Year:
- 2015
- Volume:
- 16
- Issue:
- 9
- Issue Sort Value:
- 2015-0016-0009-0000
- Page Start:
- Page End:
- Publication Date:
- 2015-11
- Subjects:
- cardiac -- cardiac surgery -- extubation failure -- mechanical ventilation
Pediatric intensive care -- Periodicals
Pediatric emergencies -- Periodicals
618.05 - Journal URLs:
- http://www.mdconsult.com/public/search?search_type=journal&j_sort=pub_date&j_issn=1529-7535 ↗
http://gateway.ovid.com/ovidweb.cgi?T=JS&PAGE=toc&D=ovft&MODE=ovid&NEWS=N&AN=00130478-000000000-00000 ↗
http://journals.lww.com/pccmjournal/pages/default.aspx ↗
http://www.mdconsult.com/about/journallist/192093418-5/about0041.html ↗
http://www.pccmjournal.com/ ↗
http://journals.lww.com ↗ - DOI:
- 10.1097/PCC.0000000000000498 ↗
- Languages:
- English
- ISSNs:
- 1529-7535
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 6417.565000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File: