Comparison of Tidal Volumes at the Endotracheal Tube and at the Ventilator*. Issue 9 (November 2015)
- Record Type:
- Journal Article
- Title:
- Comparison of Tidal Volumes at the Endotracheal Tube and at the Ventilator*. Issue 9 (November 2015)
- Main Title:
- Comparison of Tidal Volumes at the Endotracheal Tube and at the Ventilator*
- Authors:
- Kim, Paul
Salazar, Adler
Ross, Patrick A.
Newth, Christopher J. L.
Khemani, Robinder G. - Abstract:
- Abstract : Objective: Lung protective ventilation for children with acute respiratory distress syndrome requires accurate assessment of tidal volume. Although modern ventilators compensate for ventilator tubing compliance, tidal volume measured at the ventilator may not be accurate, particularly in small children. Although ventilator-specific proximal flow sensors that measure tidal volume at the endotracheal tube have been developed, there is little information regarding their accuracy. We sought to test the accuracy of ventilator measured tidal volume with and without proximal flow sensors against a calibrated pneumotachometer in children. Design: Prospective, observational. Setting: Tertiary care PICU. Patients: Fifty-one endotracheally intubated and mechanically ventilated children younger than 18 years. Interventions: Tidal volumes were measured at the ventilator, using a ventilator-specific flow sensor, and a calibrated pneumotachometer connected to the SensorMedics 2600A Pediatric Pulmonary Function Cart. Measurements and Main Results: In a pressure control mode of ventilation: median tidal volume measured with the pneumotachometer (9.5 mL/kg [interquartile range, 8.2–11.7 mL/kg]) was significantly higher than tidal volume measured either at the ventilator (8.2 mL/kg [7.1–9.6 mL/kg]) or at the proximal flow sensor (8.1 mL/kg [7.2–10.0 mL/kg]) ( p < 0.001). In pressure regulated volume control mode of ventilation: median tidal volume measured with the pneumotachometerAbstract : Objective: Lung protective ventilation for children with acute respiratory distress syndrome requires accurate assessment of tidal volume. Although modern ventilators compensate for ventilator tubing compliance, tidal volume measured at the ventilator may not be accurate, particularly in small children. Although ventilator-specific proximal flow sensors that measure tidal volume at the endotracheal tube have been developed, there is little information regarding their accuracy. We sought to test the accuracy of ventilator measured tidal volume with and without proximal flow sensors against a calibrated pneumotachometer in children. Design: Prospective, observational. Setting: Tertiary care PICU. Patients: Fifty-one endotracheally intubated and mechanically ventilated children younger than 18 years. Interventions: Tidal volumes were measured at the ventilator, using a ventilator-specific flow sensor, and a calibrated pneumotachometer connected to the SensorMedics 2600A Pediatric Pulmonary Function Cart. Measurements and Main Results: In a pressure control mode of ventilation: median tidal volume measured with the pneumotachometer (9.5 mL/kg [interquartile range, 8.2–11.7 mL/kg]) was significantly higher than tidal volume measured either at the ventilator (8.2 mL/kg [7.1–9.6 mL/kg]) or at the proximal flow sensor (8.1 mL/kg [7.2–10.0 mL/kg]) ( p < 0.001). In pressure regulated volume control mode of ventilation: median tidal volume measured with the pneumotachometer (10.2 mL/kg [8.8–12.4 mL/kg]) was significantly higher than tidal volume measured either at the ventilator (8.0 mL/kg [7.1–9.7 mL/kg]) or at the proximal flow sensor (8.5 mL/kg [7.3–10.4 mL/kg]) ( p < 0.001). These findings were consistent when subgrouped by ventilator type and circuit size. Conclusions: Tidal volume measured either at the endotracheal tube with a proximal flow sensor or at the ventilator with compensation for tubing compliance are both significantly lower than tidal volume measured with a calibrated pneumotachometer. This underestimation of delivered tidal volume may be particularly important when managing children with acute respiratory distress syndrome. … (more)
- Is Part Of:
- Pediatric critical care medicine. Volume 16:Issue 9(2015)
- Journal:
- Pediatric critical care medicine
- Issue:
- Volume 16:Issue 9(2015)
- Issue Display:
- Volume 16, Issue 9 (2015)
- Year:
- 2015
- Volume:
- 16
- Issue:
- 9
- Issue Sort Value:
- 2015-0016-0009-0000
- Page Start:
- Page End:
- Publication Date:
- 2015-11
- Subjects:
- acute respiratory distress syndrome -- mechanical ventilators -- pediatrics -- pulmonary function test -- tidal volume
Pediatric intensive care -- Periodicals
Pediatric emergencies -- Periodicals
618.05 - Journal URLs:
- http://www.mdconsult.com/public/search?search_type=journal&j_sort=pub_date&j_issn=1529-7535 ↗
http://gateway.ovid.com/ovidweb.cgi?T=JS&PAGE=toc&D=ovft&MODE=ovid&NEWS=N&AN=00130478-000000000-00000 ↗
http://journals.lww.com/pccmjournal/pages/default.aspx ↗
http://www.mdconsult.com/about/journallist/192093418-5/about0041.html ↗
http://www.pccmjournal.com/ ↗
http://journals.lww.com ↗ - DOI:
- 10.1097/PCC.0000000000000515 ↗
- Languages:
- English
- ISSNs:
- 1529-7535
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 6417.565000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 4972.xml