Measuring Infant Visual Acuity with Gaze Tracker Monitored Visual Fixation. Issue 7 (July 2015)
- Record Type:
- Journal Article
- Title:
- Measuring Infant Visual Acuity with Gaze Tracker Monitored Visual Fixation. Issue 7 (July 2015)
- Main Title:
- Measuring Infant Visual Acuity with Gaze Tracker Monitored Visual Fixation
- Authors:
- Hathibelagal, Amithavikram R.
Leat, Susan J.
Irving, Elizabeth L.
Nandakumar, Krithika
Eizenman, Moshe - Abstract:
- ABSTRACT: Purpose: To validate a method of measuring grating acuity with remote gaze tracking (GT) against a current clinical test of visual acuity (VA), the Teller Acuity Cards (TACs), as part of the development of an automated VA test for infants. Methods: Visual acuity for computer-generated horizontal square-wave gratings was determined from relative fixation time on a grating area compared with the background. In experiment 1, binocular VA was based on eye movements with a GT in 15 uncorrected myopic adults and compared with VA measured with subjective responses with the same stimuli and with the TACs. In experiment 2, binocular VA was determined in 19 typically developing infants aged 3 to 11 months on two visits with both the GT and TACs. Results: In adults, the mean difference between VA measured by the GT and TACs was 0.01 log cycles per degree (cpd) and the 95% limits of agreement were 0.11. One hundred percent of GT VA results were within 0.5 octave of the TACs' VAs. The mean difference between the GT and TACs for infants was 0.17 log cpd on both the first and second visit (95% limits of agreement, 0.42 and 0.47, respectively). The mean difference between test and retest for infant GT VA was 0.06 log cpd, and limits of agreement for repeatability were 0.48 log cpd. In infants, both the TACs and the GT had a reliability of 89% within less than or equal to 1 octave between visits. Gaze tracking VA improved with age and is in agreement with published norms.ABSTRACT: Purpose: To validate a method of measuring grating acuity with remote gaze tracking (GT) against a current clinical test of visual acuity (VA), the Teller Acuity Cards (TACs), as part of the development of an automated VA test for infants. Methods: Visual acuity for computer-generated horizontal square-wave gratings was determined from relative fixation time on a grating area compared with the background. In experiment 1, binocular VA was based on eye movements with a GT in 15 uncorrected myopic adults and compared with VA measured with subjective responses with the same stimuli and with the TACs. In experiment 2, binocular VA was determined in 19 typically developing infants aged 3 to 11 months on two visits with both the GT and TACs. Results: In adults, the mean difference between VA measured by the GT and TACs was 0.01 log cycles per degree (cpd) and the 95% limits of agreement were 0.11. One hundred percent of GT VA results were within 0.5 octave of the TACs' VAs. The mean difference between the GT and TACs for infants was 0.17 log cpd on both the first and second visit (95% limits of agreement, 0.42 and 0.47, respectively). The mean difference between test and retest for infant GT VA was 0.06 log cpd, and limits of agreement for repeatability were 0.48 log cpd. In infants, both the TACs and the GT had a reliability of 89% within less than or equal to 1 octave between visits. Gaze tracking VA improved with age and is in agreement with published norms. Conclusions: The agreement between the TACs and GT in adults and infants validates the method of measuring grating acuity with the remote GT. These results demonstrate its potential for an automated test of infant VA. … (more)
- Is Part Of:
- Optometry and vision science. Volume 92:Issue 7(2015)
- Journal:
- Optometry and vision science
- Issue:
- Volume 92:Issue 7(2015)
- Issue Display:
- Volume 92, Issue 7 (2015)
- Year:
- 2015
- Volume:
- 92
- Issue:
- 7
- Issue Sort Value:
- 2015-0092-0007-0000
- Page Start:
- Page End:
- Publication Date:
- 2015-07
- Subjects:
- gaze tracker -- grating acuity -- eye movements -- visual fixation -- infant vision -- preferential looking
Optometry -- Periodicals
Physiological optics -- Periodicals
Vision disorders -- Periodicals
617.7505 - Journal URLs:
- http://gateway.ovid.com/ovidweb.cgi?T=JS&MODE=ovid&PAGE=toc&D=ovft&AN=00006324-000000000-00000 ↗
http://www.optvissci.com ↗
http://journals.lww.com ↗ - DOI:
- 10.1097/OPX.0000000000000613 ↗
- Languages:
- English
- ISSNs:
- 1040-5488
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 6276.450000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 4969.xml