Haemostasis monitored in stored red blood cells, plasma and platelet concentrates in the proportion of 4 : 4 : 1 diluted with crystalloids and colloids. Issue 3 (April 2016)
- Record Type:
- Journal Article
- Title:
- Haemostasis monitored in stored red blood cells, plasma and platelet concentrates in the proportion of 4 : 4 : 1 diluted with crystalloids and colloids. Issue 3 (April 2016)
- Main Title:
- Haemostasis monitored in stored red blood cells, plasma and platelet concentrates in the proportion of 4 : 4 : 1 diluted with crystalloids and colloids
- Authors:
- Ågren, Anna
Edgren, Gustaf
Ambrosio, Daniela
Gryfelt, Gunilla
Östlund, Anders
Wikman, Agneta - Abstract:
- Abstract : The aim of this in-vitro study was to evaluate haemostasis analysed with thromboelastometry and blood gas and blood count variables, in stored blood components and the effects after dilution with Ringeŕs acetate, albumin and hydroxyethyl starch (HES). Aliquots from stored red blood cells, plasma and platelet concentrates were mixed in the proportion of 4 : 4 : 1 and analysed with rotational thromboelastometry (ROTEM), blood count [haemoglobin (Hb), haematocrit, platelet count] and blood gas (pH, calcium, sodium, potassium, glucose levels). The blood mix was thereafter diluted 20 and 33% with Ringer's acetate, albumin or HES. The stored blood component mix in a ratio of 4 : 4 : 1 had a low pH (7.11 ± 0.03, mean ± standard deviation), nonmeasurable calcium level, and high concentrations of sodium, potassium and glucose but ROTEM curves within normal range after recalcification. With Ringer's acetate dilution, the ROTEM variables changed almost linearly with increasing dilution volume. When albumin was used in the 33% dilution, the clot firmness of the fibrin clot (FibTEM) was further reduced, and with HES dilution, there was a pronounced impairment. The stored blood mix had a low pH and calcium level, both of which might have a significant influence on the coagulation process but normal ROTEM curves after recalcification. Dilution with Ringer's acetate and albumin resulted in moderate deterioration, while dilution with HES showed severely impaired haemostasis.
- Is Part Of:
- Blood coagulation and fibrinolysis. Volume 27:Issue 3(2016)
- Journal:
- Blood coagulation and fibrinolysis
- Issue:
- Volume 27:Issue 3(2016)
- Issue Display:
- Volume 27, Issue 3 (2016)
- Year:
- 2016
- Volume:
- 27
- Issue:
- 3
- Issue Sort Value:
- 2016-0027-0003-0000
- Page Start:
- 334
- Page End:
- 339
- Publication Date:
- 2016-04
- Subjects:
- blood coagulation -- blood coagulation factors -- blood coagulation tests -- colloids -- thromboelastometry
Blood -- Coagulation -- Periodicals
Fibrinolysis -- Periodicals
Hemostasis -- Periodicals
Thrombosis -- Periodicals
Blood Coagulation -- Periodicals
Fibrinolysis -- Periodicals
Hemostasis -- Periodicals
Thrombosis -- Periodicals
612.115 - Journal URLs:
- http://gateway.ovid.com/ovidweb.cgi?T=JS&MODE=ovid&PAGE=toc&D=ovft&AN=00001721-000000000-00000 ↗
http://www.bloodcoagulation.com/ ↗
http://journals.lww.com/pages/default.aspx ↗
http://firstsearch.oclc.org ↗ - DOI:
- 10.1097/MBC.0000000000000433 ↗
- Languages:
- English
- ISSNs:
- 0957-5235
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 2112.650000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 4960.xml