Impact of silicone and metal port-a-cath implants on superficial hyperthermia treatment quality. (12th December 2014)
- Record Type:
- Journal Article
- Title:
- Impact of silicone and metal port-a-cath implants on superficial hyperthermia treatment quality. (12th December 2014)
- Main Title:
- Impact of silicone and metal port-a-cath implants on superficial hyperthermia treatment quality
- Authors:
- Trujillo-Romero, Citlalli Jessica
Paulides, Margarethus Marius
Drizdal, Tomas
van Rhoon, Gerard C. - Abstract:
- Abstract: Purpose : A port-a-cath is a device implanted under the skin for continuous drug administration. It is composed of a catheter and a silicone or metal reservoir. A simulation study was done to assess the impact of a port-a-cath implant on the quality of superficial hyperthermia treatments applied using the Lucite cone applicator (LCA). Methods : Specific absorption rate (SAR) and temperature distributions were predicted using SEMCAD-X (version 14.8). We simulated 72 arrangements: two LCA-implant set-ups (central port-a-cath or at an edge below the LCA footprint), six translations of the LCA per set-up, two LCA orientations (Parallel or perpendicular electric field direction) per set-up, two implant materials (silicon or metal) and a control without port-a-cath. Treatment quality was quantified by the average 1 g SAR coverage (CV25% ), i.e. volume within the 25% iso-SAR surface, and the volume within the 40 °C iso-temperature surface (CV40 °C ). Results : CV25% reduced with a silicon port-a-cath located below the LCA footprint. In the worst scenario, only 64% of the CV25% of the control set-up was achieved. For a metal port-a-cath below the LCA aperture, dramatic reductions of CV25% were predicted: worst scenario down to 12.1% of the control CV25% . For the CV40 °C the worst case values were 74.5% and 6.5%, for silicon and metal implants, respectively. Conclusions : A silicone port-a-cath below the LCA had a smaller effect on treatment quality than a metal implant.Abstract: Purpose : A port-a-cath is a device implanted under the skin for continuous drug administration. It is composed of a catheter and a silicone or metal reservoir. A simulation study was done to assess the impact of a port-a-cath implant on the quality of superficial hyperthermia treatments applied using the Lucite cone applicator (LCA). Methods : Specific absorption rate (SAR) and temperature distributions were predicted using SEMCAD-X (version 14.8). We simulated 72 arrangements: two LCA-implant set-ups (central port-a-cath or at an edge below the LCA footprint), six translations of the LCA per set-up, two LCA orientations (Parallel or perpendicular electric field direction) per set-up, two implant materials (silicon or metal) and a control without port-a-cath. Treatment quality was quantified by the average 1 g SAR coverage (CV25% ), i.e. volume within the 25% iso-SAR surface, and the volume within the 40 °C iso-temperature surface (CV40 °C ). Results : CV25% reduced with a silicon port-a-cath located below the LCA footprint. In the worst scenario, only 64% of the CV25% of the control set-up was achieved. For a metal port-a-cath below the LCA aperture, dramatic reductions of CV25% were predicted: worst scenario down to 12.1% of the control CV25% . For the CV40 °C the worst case values were 74.5% and 6.5%, for silicon and metal implants, respectively. Conclusions : A silicone port-a-cath below the LCA had a smaller effect on treatment quality than a metal implant. Based on this study we recommend verifying heating quality by 3D patient-specific treatment planning when a port-a-cath is located below the footprint of the applicator. … (more)
- Is Part Of:
- International journal of hyperthermia. Volume 31:Number 1(2015)
- Journal:
- International journal of hyperthermia
- Issue:
- Volume 31:Number 1(2015)
- Issue Display:
- Volume 31, Issue 1 (2015)
- Year:
- 2015
- Volume:
- 31
- Issue:
- 1
- Issue Sort Value:
- 2015-0031-0001-0000
- Page Start:
- 15
- Page End:
- 22
- Publication Date:
- 2014-12-12
- Subjects:
- Implants -- port-a-cath -- superficial hyperthermia -- thermal modelling -- treatment planning
Thermotherapy -- Periodicals
615.832 - Journal URLs:
- http://informahealthcare.com/loi/hth ↗
http://www.tandf.co.uk/journals/titles/02656736.asp ↗
http://informahealthcare.com ↗ - DOI:
- 10.3109/02656736.2014.985748 ↗
- Languages:
- English
- ISSNs:
- 0265-6736
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4542.297000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 4950.xml