Evaluation of a dual-room sliding gantry CT concept for workflow optimisation in polytrauma and regular in- and outpatient management. Issue 1 (January 2015)
- Record Type:
- Journal Article
- Title:
- Evaluation of a dual-room sliding gantry CT concept for workflow optimisation in polytrauma and regular in- and outpatient management. Issue 1 (January 2015)
- Main Title:
- Evaluation of a dual-room sliding gantry CT concept for workflow optimisation in polytrauma and regular in- and outpatient management
- Authors:
- Frellesen, Claudia
Boettcher, Marie
Wichmann, Julian L.
Drieske, Martina
Kerl, J. Matthias
Lehnert, Thomas
Nau, Christoph
Geiger, Emmanuel
Wutzler, Sebastian
Ackermann, Hanns
Vogl, Thomas J.
Bauer, Ralf W. - Abstract:
- Highlights: A sliding gantry trauma room CT solution facilitates significantly faster polytrauma management. Faster and more efficient resumption of regularly scheduled patients due to a two room solution is supported. Sliding gantry CT achieves the same patient throughput as two separate conventional CT devices. Abstract: Objectives: To reveal the impact on workflow from introducing a dual-room sliding gantry CT to the trauma room for polytrauma and regularly scheduled in- outpatients with regard to efficiency and degree of capacity utilisation. Materials and methods: Time analysis was performed for 30 polytrauma patients each in 2 different trauma room settings, the new trauma room comprising a sliding gantry CT, the old one a stationary single-room CT. Complete trauma room and diagnostic workup times were manually measured and compared for both groups. In a third scenario, the number of CT scans performed with one single sliding gantry CT and the two-room concept was compared to the number of CT scans performed on two separate regular CT units in a 5 days clinical routine sample. Results: Patients demographics and type of CT examinations were comparable for all patient groups. The median time from patient arrival in the trauma room until beginning of CT scanning was 6 min shorter for the sliding gantry CT group (21 vs.15 min). Sliding gantry CT embedded in a two-room solution achieved 252 CT scans in 5 working days, compared to 250 CT scans on two separate regular CTHighlights: A sliding gantry trauma room CT solution facilitates significantly faster polytrauma management. Faster and more efficient resumption of regularly scheduled patients due to a two room solution is supported. Sliding gantry CT achieves the same patient throughput as two separate conventional CT devices. Abstract: Objectives: To reveal the impact on workflow from introducing a dual-room sliding gantry CT to the trauma room for polytrauma and regularly scheduled in- outpatients with regard to efficiency and degree of capacity utilisation. Materials and methods: Time analysis was performed for 30 polytrauma patients each in 2 different trauma room settings, the new trauma room comprising a sliding gantry CT, the old one a stationary single-room CT. Complete trauma room and diagnostic workup times were manually measured and compared for both groups. In a third scenario, the number of CT scans performed with one single sliding gantry CT and the two-room concept was compared to the number of CT scans performed on two separate regular CT units in a 5 days clinical routine sample. Results: Patients demographics and type of CT examinations were comparable for all patient groups. The median time from patient arrival in the trauma room until beginning of CT scanning was 6 min shorter for the sliding gantry CT group (21 vs.15 min). Sliding gantry CT embedded in a two-room solution achieved 252 CT scans in 5 working days, compared to 250 CT scans on two separate regular CT units with the same man power. Conclusions: Sliding gantry CT in the trauma room allows for significant time saving in the diagnostic workup of polytrauma patients and faster resumption of the regular in- outpatient's CT schedule is possible. With the same man power, the dual-room solution is able to generate the same throughput as two separate CT units. … (more)
- Is Part Of:
- European journal of radiology. Volume 84:Issue 1(2015)
- Journal:
- European journal of radiology
- Issue:
- Volume 84:Issue 1(2015)
- Issue Display:
- Volume 84, Issue 1 (2015)
- Year:
- 2015
- Volume:
- 84
- Issue:
- 1
- Issue Sort Value:
- 2015-0084-0001-0000
- Page Start:
- 117
- Page End:
- 122
- Publication Date:
- 2015-01
- Subjects:
- Sliding gantry CT -- Trauma room -- Polytrauma -- Time -- Workflow optimisation
Medical radiology -- Periodicals
Radiology -- Periodicals
Radiologie médicale -- Périodiques
Medical radiology
Periodicals
616.075705 - Journal URLs:
- http://www.sciencedirect.com/science/journal/0720048X ↗
http://www.elsevier.com/homepage/elecserv.htt ↗
http://www.clinicalkey.com/dura/browse/journalIssue/0720048X ↗
http://www.clinicalkey.com.au/dura/browse/journalIssue/0720048X ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.ejrad.2014.10.013 ↗
- Languages:
- English
- ISSNs:
- 0720-048X
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3829.738050
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 4917.xml