External validation of a simple non-invasive algorithm to rule out chronic thromboembolic pulmonary hypertension after acute pulmonary embolism. Issue 5 (May 2015)
- Record Type:
- Journal Article
- Title:
- External validation of a simple non-invasive algorithm to rule out chronic thromboembolic pulmonary hypertension after acute pulmonary embolism. Issue 5 (May 2015)
- Main Title:
- External validation of a simple non-invasive algorithm to rule out chronic thromboembolic pulmonary hypertension after acute pulmonary embolism
- Authors:
- Klok, F.A.
Tesche, C.
Rappold, L.
Dellas, C.
Hasenfuß, G.
Huisman, M.V.
Konstantinides, S.
Lankeit, M. - Abstract:
- Abstract: Purpose: International guidelines do not provide strong recommendations on the duration and intensity of follow-up after acute pulmonary embolism (PE), nor on screening-programs for chronic thromboembolic pulmonary hypertension (CTEPH). We aimed to address this gab by performing an external validation of the easy "CTEPH rule-out-criteria" based on a normal NT-proBNP level and the absence of 3 ECG characteristics. Methods: 134 patients underwent clinical follow-up 6 months after PE. Predefined transthoracic echocardiographic (TTE) criteria were used to categorize patients as "PH unlikely" or "PH possible/likely". The latter patients underwent further (invasive) diagnostic procedures to confirm and classify the diagnosis of pulmonary hypertension. NT-proBNP and ECGs, both assessed at the day of echocardiography, were evaluated post-hoc. Results: Sixty-three patients (47%) scored none of the "CTEPH rule-out criteria" positive, of whom 61 had normal TTE (97%). Twenty-five patients (19%) were categorized by TTE as "PH possible/likely"; of those, 6 were diagnosed with CTEPH. The sensitivity of rule-out criteria for CTEPH was 100% (95%CI 56-100%; 6/6 patients identified), and for "PH possible/likely" on TTE 92% (95%CI 74-99%; 23/25 patients identified): 2 asymptomatic patients with estimated systolic pulmonary arterial pressure of 36 mmHg and 38 mmHg, respectively, who remained stable during further 2-year follow-up, were not identified. Inter-observer agreement for theAbstract: Purpose: International guidelines do not provide strong recommendations on the duration and intensity of follow-up after acute pulmonary embolism (PE), nor on screening-programs for chronic thromboembolic pulmonary hypertension (CTEPH). We aimed to address this gab by performing an external validation of the easy "CTEPH rule-out-criteria" based on a normal NT-proBNP level and the absence of 3 ECG characteristics. Methods: 134 patients underwent clinical follow-up 6 months after PE. Predefined transthoracic echocardiographic (TTE) criteria were used to categorize patients as "PH unlikely" or "PH possible/likely". The latter patients underwent further (invasive) diagnostic procedures to confirm and classify the diagnosis of pulmonary hypertension. NT-proBNP and ECGs, both assessed at the day of echocardiography, were evaluated post-hoc. Results: Sixty-three patients (47%) scored none of the "CTEPH rule-out criteria" positive, of whom 61 had normal TTE (97%). Twenty-five patients (19%) were categorized by TTE as "PH possible/likely"; of those, 6 were diagnosed with CTEPH. The sensitivity of rule-out criteria for CTEPH was 100% (95%CI 56-100%; 6/6 patients identified), and for "PH possible/likely" on TTE 92% (95%CI 74-99%; 23/25 patients identified): 2 asymptomatic patients with estimated systolic pulmonary arterial pressure of 36 mmHg and 38 mmHg, respectively, who remained stable during further 2-year follow-up, were not identified. Inter-observer agreement for the adjudication of the ECG characteristics was excellent (kappa-statistic 0.97). Conclusions: In this external validation cohort, we confirmed the diagnostic accuracy and reproducibility of the "CTEPH rule-out criteria". These results provide a solid ground for future outcome trials applying this algorithm. Highlights: The CTEPH rule-out criteria consist of a simple ECG reading and NT-proBNP assessment The CTEPH rule-out criteria were shown to have a high sensitivity (100%) for CTEPH The CTEPH rule-out criteria were highly reproducible (kappa statistic 0.97) Validation of the CTEPH rule-out criteria in an outcome study is still required … (more)
- Is Part Of:
- Thrombosis research. Volume 135:Issue 5(2015)
- Journal:
- Thrombosis research
- Issue:
- Volume 135:Issue 5(2015)
- Issue Display:
- Volume 135, Issue 5 (2015)
- Year:
- 2015
- Volume:
- 135
- Issue:
- 5
- Issue Sort Value:
- 2015-0135-0005-0000
- Page Start:
- 796
- Page End:
- 801
- Publication Date:
- 2015-05
- Subjects:
- Pulmonary embolism -- Pulmonary hypertension -- NT-proBNP -- ECG -- Screening -- Echocardiography
Thrombosis -- Periodicals
616.135 - Journal URLs:
- http://www.sciencedirect.com/science/journal/00493848 ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.thromres.2014.12.009 ↗
- Languages:
- English
- ISSNs:
- 0049-3848
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 8820.365000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 4915.xml