Does the Russell Viper Venom time test provide a rapid estimation of the intensity of oral anticoagulation? A cohort study. Issue 5 (May 2015)
- Record Type:
- Journal Article
- Title:
- Does the Russell Viper Venom time test provide a rapid estimation of the intensity of oral anticoagulation? A cohort study. Issue 5 (May 2015)
- Main Title:
- Does the Russell Viper Venom time test provide a rapid estimation of the intensity of oral anticoagulation? A cohort study
- Authors:
- Douxfils, Jonathan
Chatelain, Bernard
Hjemdahl, Paul
Devalet, Bérangère
Sennesael, Anne-Laure
Wallemacq, Pierre
Rönquist-Nii, Yuko
Pohanka, Anton
Dogné, Jean-Michel
Mullier, François - Abstract:
- Abstract: Background: Dilute Russell Viper Venom Time (DRVV-T) might be useful in urgent settings for screening patients on Non-VKA Oral Anticoagulants (NOACs). Aim: To compare the accuracy of DRVV-T with gold standard assays for the assessment of pharmacodynamics of dabigatran, rivaroxaban and vitamin K antagonist (VKA) in plasma samples from patients. Methods: Sixty rivaroxaban, 48 dabigatran and 50 VKA samples from patients were included. DRVV-T was performed in all groups using STA®-Staclot®DRVV-Screen and -Confirm. For NOACs, PT and aPTT were performed using different reagents while plasma drug concentrations were measured by liquid mass-spectrometry (LC-MS/MS). For VKA, INR was performed using RecombiPlasTin 2G®. Results: For NOACs, correlations between calibrated STA®-Staclot®DRVV-Confirm and LC-MS/MS (rs = 0.88 and 0.97 for rivaroxaban and dabigatran, respectively) were higher than the ones obtained with STA®-Staclot®DRVV-Screen (rs = 0.87 and 0.91), PT (rs = 0.83 to 0.86) or aPTT (rs = 0.84 to 0.89). Bland Altman analyses showed that calibrated DRVV-T methods tend to overestimate plasma concentrations of NOACs. ROC curves revealed that cut-off to exclude supra-therapeutic levels at Ctrough (i.e. 200 ng/mL) are different for dabigatran and rivaroxaban. Neither STA®-Staclot®DRVV-Screen nor –Confirm correlated sufficiently with the intensity of VKA therapy (rs = 0.35 and 0.52). Conclusions: STA®-Staclot®DRVV-Confirm provides a rapid estimation of the intensity ofAbstract: Background: Dilute Russell Viper Venom Time (DRVV-T) might be useful in urgent settings for screening patients on Non-VKA Oral Anticoagulants (NOACs). Aim: To compare the accuracy of DRVV-T with gold standard assays for the assessment of pharmacodynamics of dabigatran, rivaroxaban and vitamin K antagonist (VKA) in plasma samples from patients. Methods: Sixty rivaroxaban, 48 dabigatran and 50 VKA samples from patients were included. DRVV-T was performed in all groups using STA®-Staclot®DRVV-Screen and -Confirm. For NOACs, PT and aPTT were performed using different reagents while plasma drug concentrations were measured by liquid mass-spectrometry (LC-MS/MS). For VKA, INR was performed using RecombiPlasTin 2G®. Results: For NOACs, correlations between calibrated STA®-Staclot®DRVV-Confirm and LC-MS/MS (rs = 0.88 and 0.97 for rivaroxaban and dabigatran, respectively) were higher than the ones obtained with STA®-Staclot®DRVV-Screen (rs = 0.87 and 0.91), PT (rs = 0.83 to 0.86) or aPTT (rs = 0.84 to 0.89). Bland Altman analyses showed that calibrated DRVV-T methods tend to overestimate plasma concentrations of NOACs. ROC curves revealed that cut-off to exclude supra-therapeutic levels at Ctrough (i.e. 200 ng/mL) are different for dabigatran and rivaroxaban. Neither STA®-Staclot®DRVV-Screen nor –Confirm correlated sufficiently with the intensity of VKA therapy (rs = 0.35 and 0.52). Conclusions: STA®-Staclot®DRVV-Confirm provides a rapid estimation of the intensity of anticoagulation with rivaroxaban or dabigatran without specific calibrators. At Ctrough, thresholds for rivaroxaban and dabigatran can be used to identify supra-therapeutic plasma level. However, this test cannot differentiate the nature of the NOACs. The development of a point-of-care device optimising this method would be of particular interest in emergency situations. Highlights: DRVV-Confirm may provide information on the intensity of anticoagulation with NOACs DRVV-Confirm is more informative than PT and aPTT to identify supra-therapeutic levels of NOACs DRVV-Confirm should not be used for the accurate estimation of plasma NOACs concentrations These results can serve as hypotheses to develop a point-of-care device … (more)
- Is Part Of:
- Thrombosis research. Volume 135:Issue 5(2015)
- Journal:
- Thrombosis research
- Issue:
- Volume 135:Issue 5(2015)
- Issue Display:
- Volume 135, Issue 5 (2015)
- Year:
- 2015
- Volume:
- 135
- Issue:
- 5
- Issue Sort Value:
- 2015-0135-0005-0000
- Page Start:
- 852
- Page End:
- 860
- Publication Date:
- 2015-05
- Subjects:
- Thrombosis -- Periodicals
616.135 - Journal URLs:
- http://www.sciencedirect.com/science/journal/00493848 ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.thromres.2015.02.020 ↗
- Languages:
- English
- ISSNs:
- 0049-3848
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 8820.365000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 4915.xml