Detection of elevated INR by thromboelastometry and thromboelastography in warfarin treated patients and healthy controls. Issue 5 (May 2015)
- Record Type:
- Journal Article
- Title:
- Detection of elevated INR by thromboelastometry and thromboelastography in warfarin treated patients and healthy controls. Issue 5 (May 2015)
- Main Title:
- Detection of elevated INR by thromboelastometry and thromboelastography in warfarin treated patients and healthy controls
- Authors:
- Schmidt, David E.
Holmström, Margareta
Majeed, Ammar
Näslin, Doris
Wallén, Håkan
Ågren, Anna - Abstract:
- Abstract: Introduction: The diagnostic potential of whole blood viscoelastic tests thromboelastography (TEG®) and thromboelastometry (ROTEM®) to detect warfarin-induced INR elevation remains elusive. Methods: Viscoelastic tests were performed in 107 patients on warfarin and 89 healthy controls. Tests were activated by kaolin for TEG, and ellagic acid (INTEM) or tissue factor (EXTEM) for ROTEM. Results: Viscoelastic tests revealed significant differences in clotting profiles between controls and warfarin-treated patients. Compared with healthy controls, patients treated with warfarin had prolonged EXTEM clotting and TEG reaction time (p < 0.001), both of which were also increased beyond the reference range. Increased INR values correlated with EXTEM CT (Spearman rho = 0.87) and TEG R-time (rho = 0.73). EXTEM CT had a sensitivity and specificity of 0.89 and 1.00, respectively, to detect elevated INR above 1.2 units, with a positive and negative predictive values (PPV and NPV) of 1.00 and 0.88, respectively. Similarly, TEG R-time had a sensitivity and specificity of 0.86 and 0.87, respectively, with a PPV of 0.89 and a NPV of 0.83. The corresponding receiver operator characteristic area under the curve was 0.99 (95% confidence interval [CI], 0.99 – 1.00) for EXTEM CT and 0.94 (95% CI, 0.91 – 0.97) for TEG R-time. Conclusions: Tissue factor-activated viscoelastic testing (EXTEM) revealed individuals with warfarin-induced INR elevation accurately, while TEG - activated throughAbstract: Introduction: The diagnostic potential of whole blood viscoelastic tests thromboelastography (TEG®) and thromboelastometry (ROTEM®) to detect warfarin-induced INR elevation remains elusive. Methods: Viscoelastic tests were performed in 107 patients on warfarin and 89 healthy controls. Tests were activated by kaolin for TEG, and ellagic acid (INTEM) or tissue factor (EXTEM) for ROTEM. Results: Viscoelastic tests revealed significant differences in clotting profiles between controls and warfarin-treated patients. Compared with healthy controls, patients treated with warfarin had prolonged EXTEM clotting and TEG reaction time (p < 0.001), both of which were also increased beyond the reference range. Increased INR values correlated with EXTEM CT (Spearman rho = 0.87) and TEG R-time (rho = 0.73). EXTEM CT had a sensitivity and specificity of 0.89 and 1.00, respectively, to detect elevated INR above 1.2 units, with a positive and negative predictive values (PPV and NPV) of 1.00 and 0.88, respectively. Similarly, TEG R-time had a sensitivity and specificity of 0.86 and 0.87, respectively, with a PPV of 0.89 and a NPV of 0.83. The corresponding receiver operator characteristic area under the curve was 0.99 (95% confidence interval [CI], 0.99 – 1.00) for EXTEM CT and 0.94 (95% CI, 0.91 – 0.97) for TEG R-time. Conclusions: Tissue factor-activated viscoelastic testing (EXTEM) revealed individuals with warfarin-induced INR elevation accurately, while TEG - activated through the intrinsic pathway – still was of acceptable diagnostic value. Further studies are required to evaluate the diagnostic potential of viscoelastic tests in relation to standard laboratory tests in other mixed patient populations, where the PPV and NPV may be inferior. Highlights: Warfarin-treated patients had prolonged EXTEM clotting time and TEG reaction time EXTEM CT had the highest positive and negative predictive values to detect INR > 1.2 EXTEM CT had a very high ROC area under the curve TEG R-time had a good ROC curve, but was inferior to EXTEM CT ROTEM/TEG allowed sensitive and specific differentiation of warfarin-treated patients … (more)
- Is Part Of:
- Thrombosis research. Volume 135:Issue 5(2015)
- Journal:
- Thrombosis research
- Issue:
- Volume 135:Issue 5(2015)
- Issue Display:
- Volume 135, Issue 5 (2015)
- Year:
- 2015
- Volume:
- 135
- Issue:
- 5
- Issue Sort Value:
- 2015-0135-0005-0000
- Page Start:
- 1007
- Page End:
- 1011
- Publication Date:
- 2015-05
- Subjects:
- Thrombosis -- Periodicals
616.135 - Journal URLs:
- http://www.sciencedirect.com/science/journal/00493848 ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.thromres.2015.02.022 ↗
- Languages:
- English
- ISSNs:
- 0049-3848
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 8820.365000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 4916.xml