The image quality and lesion characterization of breast using automated whole-breast ultrasound: A comparison with handheld ultrasound. Issue 7 (July 2015)
- Record Type:
- Journal Article
- Title:
- The image quality and lesion characterization of breast using automated whole-breast ultrasound: A comparison with handheld ultrasound. Issue 7 (July 2015)
- Main Title:
- The image quality and lesion characterization of breast using automated whole-breast ultrasound: A comparison with handheld ultrasound
- Authors:
- An, Yeong Yi
Kim, Sung Hun
Kang, Bong Joo - Abstract:
- Highlights: The image quality of AWUS was comparable to that of HHUS for lesion characterization. In only 0.5%, the poor quality of AWUSimages inhibited precise interpretations. The HHUS was superior to AWUS in the analysis of peripherally located, irregular, non-circumscribed, or BI-RADS category 4 or 5 lesions. Abstract: Objective: To prospectively evaluate the image quality of automated whole breast ultrasonography (AWUS) in the characterization of breast lesions compared with handheld breast ultrasonography (HHUS). Materials and methods: This prospective study included a total of 411 lesions in 209 women. All patients underwent both HHUS and AWUS prior to biopsy. An evaluation of identical image pairs of 411 lesions obtained from both modalities was performed, and the image quality of AWUS was compared with that of HHUS as a reference standard. The overall image quality was evaluated for lesion coverage, lesion conspicuity, and artifact effect using a graded score. Additionally, the factors that correlated with differences in image quality between the two modalities were analyzed. Results: In 97.1%, the image quality of AWUS was identical or superior to that of HHUS, whereas AWUS was inferior in 2.9%. In only 0.5%, the poor quality of AWUS images caused by incomplete lesion coverage and shadowing due to a contact artifact inhibited precise interpretations. The two main causes resulting in degraded AWUS image quality were blurring of the margin (83.3%) and acousticHighlights: The image quality of AWUS was comparable to that of HHUS for lesion characterization. In only 0.5%, the poor quality of AWUSimages inhibited precise interpretations. The HHUS was superior to AWUS in the analysis of peripherally located, irregular, non-circumscribed, or BI-RADS category 4 or 5 lesions. Abstract: Objective: To prospectively evaluate the image quality of automated whole breast ultrasonography (AWUS) in the characterization of breast lesions compared with handheld breast ultrasonography (HHUS). Materials and methods: This prospective study included a total of 411 lesions in 209 women. All patients underwent both HHUS and AWUS prior to biopsy. An evaluation of identical image pairs of 411 lesions obtained from both modalities was performed, and the image quality of AWUS was compared with that of HHUS as a reference standard. The overall image quality was evaluated for lesion coverage, lesion conspicuity, and artifact effect using a graded score. Additionally, the factors that correlated with differences in image quality between the two modalities were analyzed. Results: In 97.1%, the image quality of AWUS was identical or superior to that of HHUS, whereas AWUS was inferior in 2.9%. In only 0.5%, the poor quality of AWUS images caused by incomplete lesion coverage and shadowing due to a contact artifact inhibited precise interpretations. The two main causes resulting in degraded AWUS image quality were blurring of the margin (83.3%) and acoustic shadowing by Cooper's ligament or improper compression pressure of the transducer (66.7%). Among various factors, peripheral location from the nipple ( p = 0.01), lesion size ( p = 0.02), shape descriptor ( p = 0.02), and final American College of Radiology Breast Imaging Reporting and Data System (BI-RADS) category ( p = 0.001) were correlated with differences in image quality between AWUS and HHUS. Conclusion: Although the image quality of AWUS was comparable to that of HHUS for lesion interpretation, HHUS was clearly superior to AWUS for analyzing lesions with a peripheral location, an irregular shape, a non-circumscribed margin and BI-RADS category 4 or 5. … (more)
- Is Part Of:
- European journal of radiology. Volume 84:Issue 7(2015)
- Journal:
- European journal of radiology
- Issue:
- Volume 84:Issue 7(2015)
- Issue Display:
- Volume 84, Issue 7 (2015)
- Year:
- 2015
- Volume:
- 84
- Issue:
- 7
- Issue Sort Value:
- 2015-0084-0007-0000
- Page Start:
- 1232
- Page End:
- 1235
- Publication Date:
- 2015-07
- Subjects:
- Ultrasound -- Breast -- Automated whole breast US -- BI-RADS
Medical radiology -- Periodicals
Radiology -- Periodicals
Radiologie médicale -- Périodiques
Medical radiology
Periodicals
616.075705 - Journal URLs:
- http://www.sciencedirect.com/science/journal/0720048X ↗
http://www.elsevier.com/homepage/elecserv.htt ↗
http://www.clinicalkey.com/dura/browse/journalIssue/0720048X ↗
http://www.clinicalkey.com.au/dura/browse/journalIssue/0720048X ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.ejrad.2015.04.007 ↗
- Languages:
- English
- ISSNs:
- 0720-048X
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3829.738050
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 4876.xml