Source apportionment of CO2, PM10 and VOCs levels and health risk assessment in naturally ventilated primary schools in Porto, Portugal. (1st February 2016)
- Record Type:
- Journal Article
- Title:
- Source apportionment of CO2, PM10 and VOCs levels and health risk assessment in naturally ventilated primary schools in Porto, Portugal. (1st February 2016)
- Main Title:
- Source apportionment of CO2, PM10 and VOCs levels and health risk assessment in naturally ventilated primary schools in Porto, Portugal
- Authors:
- Madureira, Joana
Paciência, Inês
Rufo, João
Severo, Milton
Ramos, Elisabete
Barros, Henrique
de Oliveira Fernandes, Eduardo - Abstract:
- Abstract: Children are by far more susceptible to the negative effects of air pollutants than adults. Building-level characteristics are structural factors largely beyond the control of those who live in them. Yet, there are gaps in understanding of the relationship of school building characteristics and/or occupant behaviour and indoor air parameters with implications for health and well-being. The aims of the study were to investigate the potential sources of CO2, PM10 and volatile organic compound (VOCs) in naturally ventilated primary schools and to assess the potential health hazards of PM10 on schoolchildren. CO2 and PM10 levels were determined in seventy three classrooms located in Porto city over a period of 8 h using low-drift NDIR sensors and light-scattering laser photometers, respectively. The VOCs samples were collected over 5-days in Tenax TA tubes and then analysed by gas chromatography coupled mass spectrometry. Principal component analysis revealed the influence of activities or building features as major sources of indoor CO2, PM10 and VOCs associated to the reduced airing of the classrooms which underlines the influence of indoor sources, occupant behaviour and maintenance/cleaning activities in schools and the high density of occupants. The hazard quotient calculated based on the formula suggested by the United States Environmental Protection Agency is higher than the acceptable level of 1; being for children almost twelve times higher than the safeAbstract: Children are by far more susceptible to the negative effects of air pollutants than adults. Building-level characteristics are structural factors largely beyond the control of those who live in them. Yet, there are gaps in understanding of the relationship of school building characteristics and/or occupant behaviour and indoor air parameters with implications for health and well-being. The aims of the study were to investigate the potential sources of CO2, PM10 and volatile organic compound (VOCs) in naturally ventilated primary schools and to assess the potential health hazards of PM10 on schoolchildren. CO2 and PM10 levels were determined in seventy three classrooms located in Porto city over a period of 8 h using low-drift NDIR sensors and light-scattering laser photometers, respectively. The VOCs samples were collected over 5-days in Tenax TA tubes and then analysed by gas chromatography coupled mass spectrometry. Principal component analysis revealed the influence of activities or building features as major sources of indoor CO2, PM10 and VOCs associated to the reduced airing of the classrooms which underlines the influence of indoor sources, occupant behaviour and maintenance/cleaning activities in schools and the high density of occupants. The hazard quotient calculated based on the formula suggested by the United States Environmental Protection Agency is higher than the acceptable level of 1; being for children almost twelve times higher than the safe level. This indicates that the inhalation exposure to PM10 by children and adults occupying the school environment is not negligible. Highlights: Potential sources of CO2, PM10 and VOCs was determined. PCA revealed the influence of activities or building features as major sources of indoor pollution. Children exhibited dose rates twice higher than adults. The PM10 hazard quotient is higher than the acceptable level of 1. Inhalation exposure to PM10 by children and adults is not negligible. … (more)
- Is Part Of:
- Building and environment. Volume 96(2016)
- Journal:
- Building and environment
- Issue:
- Volume 96(2016)
- Issue Display:
- Volume 96, Issue 2016 (2016)
- Year:
- 2016
- Volume:
- 96
- Issue:
- 2016
- Issue Sort Value:
- 2016-0096-2016-0000
- Page Start:
- 198
- Page End:
- 205
- Publication Date:
- 2016-02-01
- Subjects:
- Particulate matter -- School building -- PCA -- Source apportionment -- Exposure dose -- Health risk
Buildings -- Environmental engineering -- Periodicals
Building -- Research -- Periodicals
Constructions -- Technique de l'environnement -- Périodiques
Electronic journals
696 - Journal URLs:
- http://www.sciencedirect.com/science/journal/03601323 ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.buildenv.2015.11.031 ↗
- Languages:
- English
- ISSNs:
- 0360-1323
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 2359.355000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 4871.xml